Dell Computer Drive - Manuals
Dell Computer Drive – Manual in PDF format online.
Manuals:
Manual Dell Computer Drive
Summary
Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. ____________________ Information in this document is subject to chang...
Contents 3 C o n t e n t s 1 A b o u t T h i s G u i d e . . . . . . . . . . . . . . . . . . . 1 1 User Interface . . . . . . . . . . . . . . . . . . . . . . 11 Summary Tab . . . . . . . . . . . . . . . . . . . . 12 Configure Tab . . . . . . . . . . . . . . . . . . . 12 Modify Tab . . . . . . . . . ...
4 Contents Setting a Password . . . . . . . . . . . . . . . . . . . 21 Password Guidelines . . . . . . . . . . . . . . . . 22 Resetting a Password . . . . . . . . . . . . . . . . . . 22 Connecting the Serial Cable . . . . . . . . . . . . 22 System Setup for Password Reset . . . . . . . . . 23 Reset ...
6 Contents 6 D i s k G r o u p s a n d Vi r t u a l D i s k s . . . . . . . . . 5 3 Creating Disk Groups and Virtual Disks . . . . . . . . 54 Automatic Configuration . . . . . . . . . . . . . . 55 Manual Configuration . . . . . . . . . . . . . . . 55 Hot Spare Drive Protection . . . . . . . . . . . ...
8 Contents Creating a Virtual Disk Copy . . . . . . . . . . . . . . 87 Preparing Host Servers to Create a Virtual Disk Copy . . . . . . . . . . . . . . . . . . . . . . 87 Copying the Virtual Disk . . . . . . . . . . . . . . 88 Storage Array Performance During Virtual Disk Copy . . . . . . . . . . . ...
Contents 9 Device Health Conditions . . . . . . . . . . . . . . . . 101 SMrepassist Utility . . . . . . . . . . . . . . . . . . . 102 Support Information Package . . . . . . . . . . . . . . 103 Unidentified Devices . . . . . . . . . . . . . . . . . . 104 Recovering from an Unidentified Storage Array...
About This Guide 11 About This Guide Dell™ PowerVault™ Modular Disk (MD) Storage Manager software is used to create and manage multiple storage arrays. The software can be used on any host attached to the storage array, as well as on storage management stations connected to the same sub-network. MD ...
12 About This Guide • Beneath the Array Selector is the Content Area . Several tabs appear in this area to group the tasks you can perform on the selected array. When you click on a tab, the Content Area displays links for the tasks you can perform. The following sections list some of the tasks you ...
About This Guide 13 Tools Tab • Rename a storage array • Set or change a password • View or enable premium features • Turn on indicator lights • Change enclosure ID numbers • Set or change enclosure tags • Set up e-mail alerts and SNMP alerts • Synchronize controller clocks, change the network confi...
14 About This Guide • View online help • View the event log Other Information You May Need CAUTION: For complete regulatory and safety information, see your Product Information Guide . Warranty information may be included within this document or as a separate one. • Setting Up Your Dell PowerVault M...
Storage Array 15 About Your Storage Array This chapter covers basic information about how to manage storage arrays from MD Storage Manager, including adding and removing arrays from the software, performing initial setup tasks, setting passwords on an array, and configuring alert notifications. For ...
Storage Array 17 Adding Storage Arrays To add a storage array to MD Storage Manager, click New in the Array Selector area. A window is displayed that allows you to choose the automatic or manual process to add a new storage array. NOTE: Verify that your host or management station network configurati...
18 Storage Array • To add a storage array that uses out-of-band management, specify the host name or IP address of each controller in the storage array. NOTE: It can take several minutes for MD Storage Manager to connect to the specified storage array. Naming Storage Arrays Each storage array should...
Storage Array 19 To remove a storage array: 1 Click Remove located to the right of the drop-down menu in the Array Selector. 2 Click OK in the Remove dialog box. You can still manage the storage array from other storage management stations where it has been added. Setting Up Your Storage Array The P...
Storage Array 21 Storage Array Support Data Aggregated support data can be generated for a storage array to aid in remote troubleshooting and issue analysis. To generate the support data report: 1 Click the Support tab, then click Gather Support Information . 2 Click Browse to display the Collect Al...
22 Storage Array To remove a password: • Enter the current password in the Current password text box. • Leave the New password and Confirm new password text boxes blank. If you forget your password, contact Dell for technical assistance. Password Guidelines Consider these guidelines when you create ...
Storage Array 23 System Setup for Password Reset Microsoft ® Windows ® Operating Systems 1 Click Start → Programs → Accessories → Communication → HyperTerminal to run HyperTerminal. If HyperTerminal is not installed, click Control Panel → Add/Remove Programs → Add/Remove Windows Components , find Hy...
24 Storage Array 7 Press <I> to set the speed to 115200. 8 P ress <Q> to set the data , parity , and stopbits to 8-N-1 , then press <Enter>. 9 Press <Enter> to exit the Comm Parameters screen. 10 Select Exit and press <Enter> again to exit the setup screen. Reset Passwo...
Storage Array 25 NOTE: If you require help with this procedure, contact Dell for technical assistance. For more information on contacting Dell, see the "Getting Help" chapter of the Hardware Owners Manua l. Changing Expansion Enclosure ID Numbers When an MD1000 expansion enclosure is attache...
Storage Array 27 • Every x hours — Sends an e-mail at the specified interval if an event occurred during that period. You can select this option only if the Information to send option is set to Event + Profile or Event + Support . 4 Click Save . Configuring SNMP Alerts To add a management console to...
Using iSCSI 31 Using iSCSI This chapter provides information on using iSCSI in MD Storage Manager. For iSCSI prerequisite requirements and detailed step-by-step instructions on setting up and configuring iSCSI, see the Installation Guide . Using the iSCSI Tab The iSCSI tab is shown in the MD Storage...
32 Using iSCSI Changing the iSCSI Target Authentication If an initiator requires mutual (bi-directional) authentication see "Entering Mutual Authentication Permissions" on page 32. 1 Click the iSCSI tab, and then click Change Target Authentication . 2 Select None if no authentication is requ...
34 Using iSCSI Changing the iSCSI Target Identification You cannot change the iSCSI target name, but you can associate an alias with the target for simpler identification. Aliases are useful because the iSCSI target names are not intuitive. You should provide an iSCSI target alias that is meaningful...
Using iSCSI 35 Configuring the MD3000i iSCSI Host Ports Use the configuration dialog for the iSCSI host ports to set up the MD3000i iSCSI host ports to use with storage arrays in a storage area network (SAN). 1 Click the iSCSI tab, and then click Configure iSCSI Host Ports . 2 Select the controller ...
36 Using iSCSI NOTE: Changing any of these settings resets the iSCSI port. I/O is interrupted to any host accessing that port. You can access the I/O automatically after the port restarts and the host logs in again. Viewing or Ending an iSCSI Session 1 Click the iSCSI tab, and then click View/End iS...
Event Monitor 41 Event Monitor An event monitor is provided with MD Storage Manager. When enabled, the event monitor runs continuously in the background and monitors activity on the managed storage arrays. If the event monitor detects any critical problems, it can notify a host or remote system usin...
42 Event Monitor Disabling the Event Monitor Disable the event monitor if you do not want the system to send alert notifications. If you are running the event monitor on multiple systems, disabling the event monitor on all but one system prevents the sending of duplicate messages. Windows 1 Select S...
About Your Host 43 About Your Host This chapter covers basic information about configuring host groups and host access, host topology, and I/O data path protection. A host is a system that accesses a storage array and is mapped to the virtual disks through one or more host connections. Hosts have th...
44 About Your Host To begin configuring host access, click the Configure tab and then click either Configure Host Access (Automatic) or Configure Host Access (Manual) . See the appropriate section for manual configuration, depending on whether you are using SAS HBA or iSCSI. Automatic Configuration ...
46 About Your Host To manually define an initiator, click New , enter the iSCSI initiator name and iSCSI initiator label in the Enter new iSCSI initiator dialog box, and then click Add . NOTE: The initiator name entered must match the name on a host server that will connect to the storage array. 5 C...
About Your Host 47 Host Groups A host group is a logical entity of two or more hosts that share access to specific virtual disks on the storage array. You create host groups with MD Storage Manager. All hosts in a host group must have the same host type (operating system). In addition, all hosts in ...
48 About Your Host 4 Select the host group to which you want to move the host. 5 Click OK . The host is moved into the host group. The host retains the virtual disk mappings assigned to it, and inherits the virtual disk mappings assigned to the group. Other hosts in the group do not inherit the mapp...
About Your Host 49 The host retains the virtual disk mappings assigned to it, and inherits the virtual disk mappings assigned to the group to which it is moved. The host loses the virtual disk mappings assigned to the group from which it was moved. Removing a Host Group This section covers removing ...
50 About Your Host Host Context Agent The host context agent discovers the host topology. The host context agent starts when the host is started and stops when the host is turned off. The topology discovered by the host context agent can be viewed by clicking Configure Host Access (Automatic) in the...
About Your Host 51 I/O Data Path Protection You can have multiple host-to-array connections for a host. Make sure to select all of the connections to the array when configuring host access to the storage array. NOTICE: Refer to the Installation Guide for more information on cabling configurations. N...
Disk Groups and Virtual Disks 53 Disk Groups and Virtual Disks Following is a list of terms used throughout this chapter: • Disk Group — A set of physical disks that are logically grouped and assigned a RAID level. Every disk group provides the overall capacity required to create one or more virtual...
54 Disk Groups and Virtual Disks Creating Disk Groups and Virtual Disks Disk groups are created in the unconfigured capacity of a storage array, and virtual disks are created in the free capacity of a disk group. The maximum number of physical disks supported in a disk group is 30. The hosts attache...
Disk Groups and Virtual Disks 55 performed in the department: Accounts Receivable (AR), Accounts Payable (AP), internal billing, and so forth. In this scenario, the AR and AP virtual disks probably need more capacity than the internal billing virtual disk. NOTE: In Linux, the host must be rebooted a...
58 Disk Groups and Virtual Disks If you plan to create multiple virtual disks, wait until you have created all the virtual disks to register them. Waiting prevents you from having to register virtual disks more than once. Linux NOTE: You need super-user (Linux) privileges to run the hot_add utility....
Disk Groups and Virtual Disks 59 coverage for the storage array. The number and type of hot spare drives is determined based on the number, type, and capacity of physical disks in the storage array. To add hot spare drive protection using automatic configuration: 1 Click the Configure tab, then clic...
60 Disk Groups and Virtual Disks Host-to-Virtual Disk Mapping After you create virtual disks, you must map them to the host(s) connected to the array. When you configure host-to-virtual disk mapping, consider these guidelines: • Each virtual disk in the storage array can be mapped to only one host o...
Disk Groups and Virtual Disks 61 4 To map the disk to a different host or host group, click Change located to the right of the list. 5 To remove the disk mapping to a host or host group, click Remove located to the right of the list. Changing Controller Ownership of the Virtual Disk If the host has ...
62 Disk Groups and Virtual Disks Administrative Tools and select the Disk Management MMC option to format and partition the disk. If the host server is running Windows Server 2008 Core version, partition and format the virtual disk using the Microsoft DiskPart utility. Disk Group and Virtual Disk Ex...
Disk Groups and Virtual Disks 63 If you receive a warning that the snapshot repository virtual disk is becoming full, you may expand the snapshot repository virtual disk from MD Storage Manager. See "Snapshot Repository Capacity" on page 79 for step-by-step instructions. Storage Array Media ...
64 Disk Groups and Virtual Disks 3 In the Select virtual disks to scan box, click the virtual disk you want to include in the media scan. NOTE: Press <Ctrl> and click to add more than one virtual disk to the media scan. Click Select All to include all virtual disks in the media scan. 4 Check t...
Disk Groups and Virtual Disks 65 Volume Shadow-Copy Service The Microsoft Volume Shadow-copy Service (VSS) is a storage management interface for Microsoft Windows operating systems. VSS enables your storage array to interact with third-party applications that use the VSS Application Programming Inte...
68 Snapshot Virtual Disks When you create a snapshot virtual disk, you specify where to create the snapshot repository virtual disk, its capacity, and other parameters. You can disable or delete the snapshot virtual disk when you no longer need it, such as when the backup is complete. If you disable...
Snapshot Virtual Disks 71 3 Remove the drive letter(s) of the source in Windows or unmount the virtual drive(s) in Linux to help guarantee a stable copy of the drive for the Snapshot. If this is not done, the snapshot operation will report that it has completed successfully, but the snapshot data wi...
Snapshot Virtual Disks 73 Creating a Snapshot Virtual Disk Using the Advanced Path About the Advanced Path Use the advanced path to choose whether to place the snapshot repository virtual disk on free capacity or unconfigured capacity and to change the snapshot repository virtual disk parameters. Yo...
76 Snapshot Virtual Disks 4 Follow any additional instructions for your operating system. Failure to follow these additional instructions can create unusable snapshot virtual disks. NOTE: If your operating system requires additional instructions, you can find those instructions in your operating sys...
78 Snapshot Virtual Disks To map later, select Map later . 15 Click Finish to create the snapshot virtual disk and the associated snapshot repository virtual disk. 16 After you have created one or more snapshot virtual disks, mount or reassign a drive letter of the source virtual disk. 17 If needed,...
Snapshot Virtual Disks 79 • Whether you use the software-supplied sequence number that (by default) populates the Snapshot virtual disk name or the Snapshot repository virtual disk name field, the next default name for a snapshot or snapshot repository virtual disk still uses the sequence number det...
80 Snapshot Virtual Disks • Any virtual disk in the disk group is in any state of modification. • The controller that has ownership of this virtual disk is currently adding capacity to another virtual disk. Each controller can add capacity to only one virtual disk at a time. • No free capacity exist...
Snapshot Virtual Disks 81 To disable a snapshot virtual disk: 1 Click the Modify tab, then click Modify snapshot virtual disks . 2 Click Disable Snapshot Virtual Disks . 3 Highlight the snapshot virtual disk to be disabled and click Disable beneath the list. 4 In the Confirm Disable Snapshot Virtual...
82 Snapshot Virtual Disks 4 Remove the drive letter(s) of the source and (if mounted) snapshot virtual disk in Windows or unmount the virtual drive(s) in Linux to help guarantee a stable copy of the drive for the Snapshot. If this is not done, the snapshot operation will report that it has completed...
Virtual Disk Copy 85 Virtual Disk Read/Write Permissions After the virtual disk copy is complete, the target virtual disk automatically becomes read-only to the hosts. The target virtual disk rejects read and write requests while the virtual disk copy operation has a status of Pending or In Progress...
86 Virtual Disk Copy Virtual Disk Copy Restrictions Before you perform any virtual disk copy tasks, understand and adhere to the restrictions listed in this section. The restrictions apply to the source virtual disk, the target virtual disk, and the storage array. • While a virtual disk copy has a s...
Virtual Disk Copy 87 Creating a Virtual Disk Copy Use the Create Virtual Disk Copies feature on the Configure tab to create a full copy of a source virtual disk. This operation overwrites any existing data on the target virtual disk. Once the virtual disk copy has started, all I/O activity to the so...
88 Virtual Disk Copy 4 Remove the drive letter(s) of the source and (if mounted) virtual disk in Windows or unmount the virtual drive(s) in Linux to help guarantee a stable copy of the drive for the virtual disk. If this is not done, the copy operation will report that it has completed successfully,...
Virtual Disk Copy 89 5 Set the copy priority for the virtual disk copy and click Next . The source virtual disk, the target virtual disk, and the copy priority setting that you selected appear on the Create virtual disk copies—Confirm Copy Settings dialog. The higher priorities allocate more resourc...
90 Virtual Disk Copy You can change the copy priority for a virtual disk copy in the following circumstances: • Before the virtual disk copy begins See "Creating a Virtual Disk Copy" on page 87. • While the virtual disk copy is in progress Click the Modify tab, then click Manage Virtual Disk...
Virtual Disk Copy 91 Preparing Host Servers to Recopy a Virtual Disk NOTICE: Before you create a new copy of a source virtual disk, stop any data access (I/O) activity or suspend data transfer to the source virtual disk (and, if applicable, the target disk) to ensure that you capture an accurate poi...
92 Virtual Disk Copy Recopying the Virtual Disk After first preparing the host server(s) as specified in the preceding procedure, complete the following steps to create a new virtual disk copy for an existing copy pair: 1 Click the Modify tab, and then click Manage virtual disk copies . You can only...
Virtual Disk Copy 93 3 You must register the target virtual disk with the operating system before you can use the new virtual disk. Perform the following steps: a Enable write permission on the target virtual disk by either removing the virtual disk copy pair (see "Removing Copy Pairs" on pa...
Firmware Downloads 95 Firmware Downloads You can download the following types of firmware images with MD Storage Manager: • RAID controller module firmware that manages the storage array controllers • RAID nonvolatile static random access memory (NVSRAM) images that specify the default settings for ...
96 Firmware Downloads Downloading Both RAID Controller and NVSRAM Firmware NOTE: I/O to the array can continue while you are upgrading RAID controller and NVSRAM firmware. NOTE: The RAID enclosure must contain at least two disk drives in order to update the firmware on the controller. Use the follow...
Firmware Downloads 97 11 A Confirm Download dialog box appears listing the current versions and the versions you selected of the RAID controller and NVSRAM firmware. To complete the download, click Yes . Downloading Only NVSRAM Firmware Use the following procedure to download NVSRAM firmware: 1 Clic...
98 Firmware Downloads 3 Click Select File to browse to the file that you want to download. By default, only firmware images that are compatible with the current storage array configuration appear. 4 Click the non-redundant-MSCS NVSRAM file in the File Selection area and then click OK . 5 If the file...
Firmware Downloads 99 7 A Confirm Download dialog box appears listing the current versions and the versions you selected of physical disk firmware. To complete the download, click Yes . Downloading EMM Firmware NOTICE: Do not make any configuration changes to the storage array while you are download...
Troubleshooting 101 Troubleshooting Problems The following sections provide information to assist you in resolving problems that may occur with your MD Storage Array. Recovery Guru The Recovery Guru is a component of MD Storage Manager that diagnoses critical events on the storage array and recommen...
102 Troubleshooting A storage array is always in one of six possible health status conditions, which you can identify by the status icon. • Optimal status — Every component in the managed device is in the desired working condition. • Needs Attention status — A problem exists with the managed device ...
Troubleshooting 103 where -f flushes all the memory-resident data for the file system indicated by < filesystem-identifier > , and < filesystem-identifier > specifies a unique file system in the following syntax: drive-letter: < mount-point-path> The file system identifier might co...
104 Troubleshooting Unidentified Devices An unidentified node or device occurs when the MD Storage Manager cannot access a new storage array. Causes for this error include network connection problems, the storage array is turned off, or the storage array does not exist. NOTE: Before beginning any re...
Hardware Considerations 107 Enclosure Hardware Replacement, Maintenance, and Configuration Considerations Removing and Inserting Enclosure Management Modules on Attached Expansion Enclosures The following procedures describe how to safely remove and insert an enclosure management module (EMM) from a...
108 Hardware Considerations 2 After attaching the SAS cables, wait at least three minutes for the EMM to reach optimal state. NOTE: You may experience a transitional failure on multiple EMMs in the MEL log while the system updates. Removing and Inserting Physical Disks Refer to the following guideli...
Index 111 Index A alert e-mail, 27SNMP, 27 B backup, 84 C Configure tab, 12 copy pairs removing, 93 copy priority, 89 D disk expansion, 62 disk group, 12, 53-55, 80 documentation, 14 download firmware, 13 E e-mail alert, 27 event monitor, 15 F free capacity, 53 H H B A p o r t , 43 host, 15 access, ...
Dell Manuals
-
Dell 04YJJ6A00
User Manual
-
Dell 04YJJ6A00
Manual
-
Dell 10 Pro
User Manual
-
Dell 10
Manual
-
Dell 1000
User Manual
-
Dell 1000
Manual
-
Dell 1014
User Manual
-
Dell 1000W
User Manual
-
Dell 1000W
Manual
-
Dell 0JH552A01
User Manual
-
Dell 10g
User Manual
-
Dell 1100
User Manual
-
Dell 1100
Manual
-
Dell 11
User Manual
-
Dell 11
Manual
-
Dell 11 Pro
User Manual
-
Dell 110T
User Manual
-
Dell 110T DLT1 Drive
User Manual
-
Dell 1100 Laser Mono Printer
User Manual
-
Dell 1100MP
User Manual