Page 3 - C o n t e n t s
Contents | 3 C o n t e n t s 1 Introduction ................................................................................ 5 BMC Key Features and Functions ............................................................. 5 2 Using the Web UI ......................................................
Page 5 - Introduction; BMC Key Features and Functions
Introduction | 5 1 Introduction This section introduces the BMC and includes the requirements for web-based graphical user interface (GUI), keyboard, video, and mouse (KVM), and virtual media. BMC Key Features and Functions The following lists the supported features of the BMC: Support for IPM...
Page 6 - Using the Web UI; Web-based GUI is supported on the following browsers:; Linux; Logging in to the Web User Interface
Using the WEB UI | 6 2 Using the Web UI The BMC firmware features an embedded web server, enabling users to connect to the BMC using an Internet browser (Microsoft Internet Explorer) without needing to install KVM and virtual storage software on a remote console. Web-based GUI is supported on th...
Page 8 - Remote Man; nagement Contr; roller GUI
Ag L T CTf T Using the WEB UI Remote M After you succgreeted with th Logout Log out from y The default tim System I System Inform Click the Syste The System In firmware revis Table Error! No BMC Informat System Powe Firmware Rev Aux FirmwarRevision Build Time | 8 Managem cessfully log in he Remo...
Page 10 - Server H
T S I c c Using the WEB UI Server H The Sensor me speed, internal Sensor Readi It reads the sen category . You click “ Show T | 10 ealth enu provides in temperature, a ings & Senso nsor informatio u can click “ Re Thresholds ” to nformation abo and voltage. r Readings w on the sy...
Page 12 - Configur
A WcTa T Using the WEB UI Configur Alerts When the BMCcomponent failThe Alerts win activate the ale To set up a des 1 Click an | 12 ration C senses a plat lure, an alert m ndow enables y erts for each ad stination to rece n Alert Numb form event, suc message can be you to enter em ddress. eive a...
Page 14 - Alert Type
Using the WEB UI 2 Select A 3 Select E Informa 4 If your | 14 Alert Type , the Event Severity ational, Warnin Alert Type is ere are two opt y , The five opti ng, Critical and Snmp Trap, typ tions, Snmp Tr ions available a d Non-recovera pe the destinat rap and Email are, Disable Al able. ion I...
Page 15 - ject
5 If your enter a b 6 Click S Alert Type is brief descriptio ave . Email, enter th on for the Subj Us he destination e ject of the ema sing the WEB UI email address, a il. | 15 and
Page 16 - Mouse mode
M Im A R N D Using the WEB UI Mouse mode It is an option tmode depends Absolute mod Relative mode Network Show the RemDHCP or STA | 16 to set up mous on OS can get e for host’s sys e for host’s syst mote Manageme ATIC IP then cl e mode which t accurate mous stem is Window tem is Linux O ent Cont...
Page 17 - MTP) server IP address for sen; nding alert not; tification to use
c SMTP Set E-mail (SMclick “ Save ”. MTP) server IP address for sen Us nding alert not sing the WEB UI tification to use | 17 er then
Page 19 - ck; Add; confirm passwo; ord and networ
Ep Enter user namprivileges, clic me, IPMI versio ck Add . on, password, c Us confirm passwo sing the WEB UI ord and networ | 19 rk
Page 24 - Click; ava Console; Mouse; item; Sync Curssor
Using the WEB UI 2 Click Ja 3 And cli | 24 ava Console . ck Mouse item m to Sync Curssor .
Page 25 - the m; console that is; s currently
B Tmbw Td v BMC Virtual The Device me media enables be available onwere present o The Device me drive, or ISO im virtualized. N d N Cv Media enu allows you a floppy image n the managed n the local syst enu in KVM di mage on the m NOTE: You must h disconnect a drive. NOTE: You can en CD/DVD drive/i...
Page 26 - Virtualizing
V Twtci M Ycr Using the WEB UI Virtualizing D The Device cli window. To vithe table. The dcheckbox. Andimage is added Mapping a Vi You can selectcheck box for aread only whic | 26 Devices ient displays th irtualize a devic device maps to d then select th d to the list of a irtual Media D t a d...
Page 27 - Mapped
U Tdc Unmapping a To unmap a virdrive. Becauseconfirm the act N sle Virtual Medi rtual media dri e some interacti tion before the NOTE: The assigne special file (Red Ha etter on this system ia Drive ive, select the M ion might be go drive is unmm ed virtual drive lette t ® Enterprise Linux m (mana...
Page 29 - Keyboard
K T Keyboard Table Error! No Dropdown Me Hold Right C Hold Right A Hold Left CT Hold Left AL Left Window text of specified enu Items CTRL Key ALT Key TRL Key LT Key ws Key style in documen Description This menu iteside <CTRL>Redirection. This menu iteside <ALT> k This menu iteside <...
Page 32 - Maintenance; Firmware Update; Web-based user interface, JPEG, and other user interface data files; Updating the BMC Firmware
Using the WEB UI | 32 Dropdown Menu Items Description Redirect ISO Enable you to start or stop the redirection of the ISO. You can choose the CD IMAGE file from client computer. Redirect Floppy / USB Enable you to start or stop the redirection of the Floppy/USB drive. You can choose the Floppy/U...
Page 36 - After th; Log In; tto log in to the BMC again.
Using the WEB UI 9 After th | 36 he BMC resets, click Log In tto log in to the BMC again.
Page 37 - Sensors Threshold
Sensors Threshold | 37 3 Sensors Threshold Table Error! No text of specified style in document. -8. Sensors Threshold Sensor Number Sensor Name The Converting Formula Upper non-recoverable Upper critical Upper non-critical Lower non-recoverable Lower critical Lower non-critical Fan 01h FCB FAN1 ...
Page 40 - Events Table; MLB TEMP 1
Events Table | 40 4 Events Table Table Error! No text of specified style in document. -9. Threshold Sensors Event Sensor Number Sensor Name Sensor Type Events 01h FCB FAN1 04h(Fan) Lower Critical – going low asserted Lower Critical – going low deasserted 02h FCB FAN2 03h FCB FAN3 04h FCB FAN4 21...
Page 52 - IPMI OEM Command List; Byte 1 – completion code
IPMI OEM Command List | 52 6 IPMI OEM Command List Table Error! No text of specified style in document. -23. OEM1 Commands (NetFn 30H, 31H) Command NetFN cmd Format Reserved Extended Configuration OEM1 01H Request: Response: Byte 1 – completion code Byte 2 - Reservation ID
Page 55 - 00b= Remaining parameters stay what it is.
IPMI OEM Command List | 55 Command NetFN cmd Format Restore to defaults OEM1 04H Request: Byte 1 -Configuration to be restored to defaults: [7:5] 111b= Restore the remaining parameters not included in below lists. 000b= Remaining parameters stay what it is. All other values are reserved [4] 1b= ...
Page 61 - NicSelection
IPMI OEM Command List | 61 Extended Configurations Table Error! No text of specified style in document. -25. Extended configurations Extended Configurations All strings are in P-String format. Configuration ID = 02h, NIC Attribute ID Size Description NicSelection 1 1 Specifies the current mode o...
Page 62 - SOL Idle Timeout
IPMI OEM Command List | 62 or Dual Channel Single Package). When user attempts to set to a NIC value that is not supported on the platform, a completion code CCh should be returned to indicate an invalid data. Configuration ID = 03h, SOL Attribute ID Size Description SOL Idle Timeout 1 2 byte1:2...
Page 63 - Lockout Window
IPMI OEM Command List | 63 Configuration (Configuration ID 0Ch). In other words, Web can only be disabled or enabled when HTTP/HTTPS is enabled. [0] - all services except IPMI are disabled. This bit takes precedence over other bits. Default is 0. [1] - KVM/Virtual Storage, enabled by default. [2...
Page 64 - Lockout Time; Number of User
IPMI OEM Command List | 64 Whenever this setting is modified, the number of authentication failure of each enabled user must be reset to 0. Default setting is 180 seconds. Lockout Time 4 2 Specifies the time period an account should be disabled if the maximum number of authentication failures is...
Page 65 - Get User Access
IPMI OEM Command List | 65 Account Status 4 1 Status of the account. This is the supplement to the byte 3 of response data of Get User Access command. Indexed by user ID. 00h = status is unspecified 01h = user ID is enabled via Set User Password 02h = user ID is disabled via Set User Password 03...
Page 66 - is the service; DNS Domain; is set; Max Web Sessions
IPMI OEM Command List | 66 character must be alphabetic. The default name is bmc- service_tag , where service_tag is the service tag number of the Dell server. For example: bmc-XG3487A. DNS Domain Name Dhcp Enable 6 1 Specifies that the DNS domain name should be assigned from the DHCP server. 0:...
Page 70 - and
IPMI OEM Command List | 70 Configuration ID = 11h, Power Management Attribute ID Size Description Power Management Enable 1 1 Specify the use of power management method. Bit 7: Enable DPNM power management 1b = enable DPNM 0b = disable DPNM Bit 6:0: reserved R/W Power Staggering AC Recovery 2 1 ...
Page 71 - Appendix; SSH/Telnet Enable and Disable; Reserved Extended Configuration
Appendix | 71 Appendix SSH/Telnet Enable and Disable 1 Reserved Extended Configuration (NetFn: 30H CMD:01H) 2 Set/Get Extended Configuration(NetFn: 30H CMD:03H/02H) Example: Get SSH/Telnet enable status: 1 Reserved Extended Configuration ipmitool raw 0x30 0x01 Response: 0x01 (Reservation ID) Con...
Page 72 - Get Extended Configuration; SSH/Telnet Redirect Enable and Disable
Appendix 72 2 Get Extended Configuration ipmitool raw 0x30 0x02 0x01 0x04 0x01 0x00 0x00 0x00 0xFF Response: 0x04 0x01 0x00 0x01 0x08 (SSH/Telnet disabled) Set SSH/Telnet Enable: 1 Reserved Extended Configuration ipmitool raw 0x30 0x01 Response: 0x02 (Reservation ID) 2 Enable SSH/Telnet ipmitool...
Page 73 - VLAN ID
Appendix | 73 Set SSH/Telnet SOL Redirect enable: 1 Reserved Extended Configuration ipmitool raw 0x30 0x01 Response: 0x02 (Reservation ID) 2 Enable SSH/Telnet SOL redirect. ipmitool raw 0x30 0x03 0x02 0x03 0x02 0x00 0x00 0x00 0x01 0x01 (set 1 to enable) Response: 0x01 VLAN ID User can use LAN co...
Page 74 - BMC/BIOS Version Info; BMC Version Info
Appendix 74 VLAN ID matches the VLAN ID value given in this parameter. [6:4] - reserved [3:0] - most significant four bits of the VLAN ID Example: 1 Get LAN Configuration Parameter command: ipmitool raw 0xC0 0x02 0x01 0x14 0x00 0x00 Response: 0x00 0x11 0x01 0x80 (VLAN Enable and VLAN ID: 1) 2 Se...
Page 76 - BIOS version; Data
A B TB U E Appendix 76 BIOS version The BIOS enabBMC early in P User can find t Byte Item 1-2 Record 3 Record 4-7 Timest 8-9 Genera 10 Event M 11 Sensor 12 Sensor 13 Event D 14 Event D 15 Event D 16 Event D Example: 1 Issu 2 ipm BIOS versio Info bles the system POST. the BIOS versi d ID d Ty...