Page 4 - GENERAL DOCUMENTATION
1.1. General information • This manual is an integral part of the product, providing all the information required to ensure correct installation, operation and maintenance of the machine. • Read the manual carefully, making reference to it for machine operation. Keep the manual in a safe place where...
Page 7 - ADVICE TO ENSURE EFFICIENT APPLIANCE OPERATION
3.1 Shut-down procedures In the event of emergency, shut down the appliance by switching off power at the main panel, by means of a breaker or power disconnect or by removing the plug from the power socket. 3.2 Operating tips Before starting up the appliance, clean the inside of the compartment thor...
Page 8 - DESCRIPTION OF THE VERTICAL CONTROL PANEL; HACCP
4. DESCRIPTION OF THE VERTICAL CONTROL PANEL +38 o 0 o +38 o HARD o C HACCP PROGRAM 6 5 15 1 12 10 3 5a 4 5b 14 7 8 9 11 2 13
Page 10 - PROGRAMMING AND OPERATING INSTRUCTIONS
5.1 STARTING UP THE APPLIANCE (only for T14D / T20C / T24C / T40) PRE HEATING FUNCTION OF COMPRESSOR SUP When power is initially supplied to the cabinet, a 2-hour pre-heating phase starts and the display shows some blinking dashes “---”. During this phase the machine cannot be started. This importan...
Page 11 - work cycles and modes can only be selected
IMPORTANT: work cycles and modes can only be selected when the appliance is ON (LED on push - button 6 off ) IMPORTANT: The appliance will automatically defrost if coil temperature falls below 45˚F. It will not go into defrost during a chill or freeze cycle. When it is in defrost a new cycle can not...
Page 14 - BLAST FREEZING BY TEMPERATURE
The time setting (in minutes) can be modified by means of push-buttons 7 4.1 PUSH-BUTTONS : 1. ON /OFF (STAND BY) 2. SOFT BLAST CHILLING CYCLE (+38°F / +3°C) 3. HARD BLAST CHILLING CYCLE (+38°F / +3°C) 4. BLAST FREEZING CYCLE (0°F / -18°C) 5. END CYCLE BY TIME / PROBE (TEMPERATURE) 5A. PROBE CHILLIN...
Page 15 - TIMED BLAST FREEZING
5.7 TIMED BLAST FREEZING • Press push-button 4 4.1 PUSH-BUTTONS : 1. ON /OFF (STAND BY) 2. SOFT BLAST CHILLING CYCLE (+38°F / +3°C) 3. HARD BLAST CHILLING CYCLE (+38°F / +3°C) 4. BLAST FREEZING CYCLE (0°F / -18°C) 5. END CYCLE BY TIME / PROBE (TEMPERATURE) 5A. PROBE CHILLING INDICATOR LED 5B. TIMED ...
Page 16 - APPLIANCE FUNCTIONS
6.1 DATE AND TIME SETTINGS : PUSH-BUTTON (5) Set the machine to ON 4.1 PUSH-BUTTONS : 1. ON /OFF (STAND BY) 2. SOFT BLAST CHILLING CYCLE (+38°F / +3°C) 3. HARD BLAST CHILLING CYCLE (+38°F / +3°C) 4. BLAST FREEZING CYCLE (0°F / -18°C) 5. END CYCLE BY TIME / PROBE (TEMPERATURE) 5A. PROBE CHILLING INDI...
Page 18 - The software controls the following alarms:
7. ALARM MANAGEMENT 7.1 Storage of data/errors The appliance electronic controller is equipped with a system of acoustic and visual signals to indicate the intervention of safety devices. The table below gives a list of the alarms shown on the panel display 7.2 The software controls the following al...
Page 19 - (Kriwan compressor automatic reset) only for T14D
Input SW2 (ALL 05) (door microswitch alarm) Cause: Input active for more than 5 minutes with appliance in start status. Door open (close door) Microswitch fault (replace the microswitch) Beeper: Activated (3 seconds, then a pause of 30 seconds) until the mute button is pressed. Display: Alternates m...
Page 22 - MAINTENANCE AND CLEANING
8. MAINTENANCE AND CLEANING The information and instructions given in this section address all persons operating the appliance: the user, the maintenance technician and non- specialised personnel. Ensure that the electrical power to the system has been disconnected before carrying out any cleaning o...
Page 23 - Delfield
Delfield ™ ® T5 : B la st C hi lle r/ Sh oc k Fr ee ze r v v v v v v v ! v v v v v v v by Delfield ® 38 38 0 ™ Model Voltage Comp. H.P. Total Max Amps Max Fuse Size Average Heat Rejected (W) Ship Weight T5 220-230/1/60 .75 10.0 12.0 2,475 275 Sample Printout .%-!0 8 9 : ' ' .%-!0 !-00(!3% !-00(!3% v...
Page 32 - T5/T14D REFRIGERATION SYSTEM SCHEMATIC
Page 38 - Supplied Equipment List.; T40 Installation and Assembly
T40 RS Wall Panel Supplied Equipment List. T40 Base T40 LS Wall Panel T40 Back Panel T40 Control Box T40 Front Panel with Door T40 Top Panel T40 Air Deflection Shields T40 Remote Condensing Unit Alignment Blocks Cam Hole Covers Cam Lock T-Handle T40 Installation and Assembly
Page 44 - Thank you for choosing Delfield!; Help is a phone call away. Help our team of professional, courteous; For a list of Delfield’s authorized parts depots,
980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (989) 773-7981 or (800) 733-8829 • Fax (888) 779-2040 • www.delfield.com Delfield reserves the right to make changes in design or specifications without prior notice. © 2007 The Delfield Company. All rights reserved. Printed in the U.S.A. Thank y...