Page 2 - Dayton Operating Instructions and Parts Manual; Product Identification
Dayton Operating Instructions and Parts Manual 2 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B Upper Shell Fuel Cap Thermostat Fuel Tank Power Cord Lower Shell Motor and PumpAssembly Hot Air Outlet Lower Shell Fuel Cap Thermostat Upper Shell Fuel Tank Power Cord Flame-Out ControlReset Button ...
Page 3 - General Safety Information; IMPORTANT
Dayton Operating Instructions and Parts Manual 3 ® Models 3E358B and 3E359B General Safety Information Make certain you read and understandall warnings. Keep these instructions forreference. They are your guide to safeand proper operation of this heater. Safety information appears throughoutthese in...
Page 4 - THEORY OF OPERATION; Figure 5 - Cross Section Operational View; THE AIR SYSTEM
Dayton Operating Instructions and Parts Manual 4 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B General Safety Information (Continued) THEORY OF OPERATION THE FUEL SYSTEM The motor turns the fuel pump. Thefuel pump pulls fuel from the fueltank. The fuel pump pushes fuelthrough a filter and a s...
Page 5 - Safety Information; Operation
Dayton Operating Instructions and Parts Manual 5 ® Models 3E358B and 3E359B Follow the mini-mum fresh, outside air ventilation requirements. If properfresh, outside air ventilation is notprovided, carbon monoxide poisoningcan occur. Provide proper fresh, outsideair ventilation before running heater....
Page 6 - To Start Heater; Figure 6 - Flame-Out Control Reset Button; NOTE
Dayton Operating Instructions and Parts Manual 6 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B Operation (Continued) TO STOP HEATER Never unplugheater while heater is running. Heater must gothrough purge cycle. The purge cyclecools the combustion chamber. Damageto heater can occur if combusti...
Page 7 - Maintenance; UPPER SHELL REMOVAL; Figure 9 - Fan Blades and Air Deflectors; SPARK PLUG; Figure 11 - Spark Plug Gap; FUEL FILTERS
Dayton Operating Instructions and Parts Manual 7 ® Models 3E358B and 3E359B Figure 8 - Upper Shell Removal, Model 3E359B Upper Shell Maintenance Never serviceheater while it is plugged in, operating, or hot. Severeburns and electrical shock can occur. UPPER SHELL REMOVAL 1. Remove screws along each ...
Page 8 - PUMP; Figure 16 - Turning Fan with Hand; Figure 14 - Fuel Pump Filter and Canister
Dayton Operating Instructions and Parts Manual 8 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B FuelFilter PumpCover Figure 13 - Fuel Pump and Filter Figure 15 - Location of Screw on Flange Clamp PUMP (Procedure if pump is binding) 1. Remove upper shell (See Figure 8, page 7). 2. Loosen hex sc...
Page 9 - Figure 19 - Replacing Nozzle; NOZZLE; Figure 18 - Fuel Lines at Pump and; FUEL LINES
Dayton Operating Instructions and Parts Manual 9 ® Models 3E358B and 3E359B Maintenance (Continued) Fuel Pump/Filter 8. Inspect nozzle for damage. If damaged or clogged, replacenozzle. 9. Make sure plug is in place on burner head. 10. Replace nozzle into burner head and tighten firmly (175-200 inch-...
Page 10 - MAINTENANCE KITS; Figure 20 - Adjusting Pump Pressure; Figure 21 - Adjusting Pump Pressure
Dayton Operating Instructions and Parts Manual 10 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B PUMP PRESSURE ADJUSTMENT FORHEATERS WITH FUEL FILTER INTER-NAL TO PUMP 1. Remove pressure gauge plug from fuel pump port marked “GAUGE.” 2. Install accessory pressure gauge (part number 110380-01) ...
Page 11 - Preventative Maintenance Schedule; How Often
Dayton Operating Instructions and Parts Manual 11 ® Models 3E358B and 3E359B Flush every 150-200 hours of operation or as needed Check for trash when filling fuel tank. Clean when dirty Clean twice a heating season or replace as needed Check and tighten loose connections occasionally Clean fuel filt...
Page 12 - Wiring Diagram; Figure 22 - Wiring Diagram
Dayton Operating Instructions and Parts Manual 12 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B Wiring Diagram 1 3 2 FAN SWITCH 7 5 B A MOTOR RELAY WHITE RED ORANGE ORANGE RED BLACK WHITE BLACK WHITE BLUE BLUE WHITE BLACK BLACK THERMOSTAT B R FLAME-OUT CONTROL RESET BUTTON RED YELLOW YELLOW R...
Page 13 - Troubleshooting Chart; Corrective Action
Dayton Operating Instructions and Parts Manual 13 ® Models 3E358B and 3E359B Troubleshooting Chart Never service heater while it is plugged in, operating, or hot.Severe burns and electrical shock can occur. Possible Cause(s) Corrective Action Symptom Motor does not start when heater isplugged in and...
Page 17 - Repair Parts List
Dayton Operating Instructions and Parts Manual 17 ® Models 3E358B and 3E359B Repair Parts List ReferenceNumber Description Part Number Qty. 1 Wiring cover 097492-03 1 2 5/16-24 x 5/16" Screw *HF5-5C 4 3 5/16" External lockwasher *WLE-5 4 4 #10-16 x 3/8" Screw *M11084-26 3 5 Motor (Model ...
Page 18 - Figure 26 - Accessory - High Pressure Fuel Gauge
Dayton Operating Instructions and Parts Manual 18 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year Please provide following information: -Model number-Serial number (if any)-Part description and number as shown in parts list ...
Page 19 - Burner Head Assembly - Figure 25; Description; Accessory - Figure 26
Dayton Operating Instructions and Parts Manual 19 ® Models 3E358B and 3E359B Repair Parts List 3E358B and 3E359B ReferenceNumber Description Part Number Qty. Burner Head Assembly - Figure 25 1 #6-32 x 3/8" Screw(Model 3E358B only) *M10908-2 2 2 Photocell bracket(Model 3E358B only) 099229-01 1 3 ...
Page 20 - Figure 27 - Repair Parts Illustration for Model 3E358B
Dayton Operating Instructions and Parts Manual 20 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year 3E358B Figure 27 - Repair Parts Illustration for Model 3E358B 1 2 2 4 5 21 2 7 8 9 10 13 11 12 14 15 16 19 20 21 4 22 23 24 25...
Page 22 - Figure 28 - Repair Parts Illustration for Model 3E359B
Dayton Operating Instructions and Parts Manual 22 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B Figure 28 - Repair Parts Illustration for Model 3E359B 1 2 2 3 4 5 13 6 7 45 46 8 9 10 11 13 14 21 18 17 15 16 23 22 24 25 33 2 4 28 30 26 27 34 25 16 2 35 36 41 42 15 43 43 44 39 38 37 15 29 12 40...
Page 24 - LIMITED WARRANTY; Portable Oil-Fired heaters, Models covered in this manual, are; NOT A UPC
Dayton Operating Instructions and Parts Manual 3E358B and 3E359B Manufactured for Dayton Electric Mfg. Co.Niles, Illinois 60714 U.S.A. 101422-01Rev. G07/02 ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Dayton ® Portable Oil-Fired heaters, Models covered in this manual, are warranted by Dayton...