Page 2 - Dayton Operating Instructions and Parts Manual; Amperage; ELECTRICAL SPECIFICATIONS; Product Identification
Dayton Operating Instructions and Parts Manual 2 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D Amperage Model Electrical Input (during normal run) 2E510E 120 Volt/60 Hertz 2.0 2E511E 120 Volt/60 Hertz 2.0 3E218E 120 Volt/60 Hertz 3.6 3E219D 120 Volt/60 Hertz 3.6 ELECTR...
Page 3 - General Safety Information; IMPORTANT; : Every possible circumstance
3 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® General Safety Information Make certain you read and understandall warnings. Keep these instructionsfor reference. They are your guide tosafe and proper operation of thisheater. Safety information app...
Page 4 - Figure 5 - Cross Section Operational View; Theory of Operation; THE FUEL SYSTEM; Fuels; • clogged fuel filter and nozzle; : Use a KEROSENE ONLY
Dayton Operating Instructions and Parts Manual 4 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D General Safety Information(Continued) Figure 5 - Cross Section Operational View CleanHeatedAir Out Air For FuelSystem Air For Combus-tion and Heating Fuel FuelFilter Air Line...
Page 5 - Assembly; Ventilation; TO START HEATER; A cold heater may affect the; TO STOP HEATER
5 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® Assembly (For Models 3E218E and 3E219D Only) These models are furnished withwheels and handles. Wheels, handles,and the mounting hardware are foundin the shipping carton. TOOLS NEEDED • MEDIUM PHILLIP...
Page 6 - Maintenance; UPPER SHELL REMOVAL; Figure 9 - Fan Cross Section
Dayton Operating Instructions and Parts Manual 6 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D AIR OUTPUT, AIR INTAKE, AND LINTFILTERS 1. Remove upper shell (See Figures 7 and 8). 2. Remove filter end cover screws using 5/16" nut-driver (See Figures 10 and 11). 3. ...
Page 7 - Figure 13 - Adjusting Pump Pressure; FUEL FILTER
7 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® Maintenance (Continued) 5. Remove pressure gauge. Replace pressure gauge plug in filter end cover. Pump Model Pressure 2E510E 3.0 psi 2E511E 3.4 psi 3E218E 5.3 psi 3E219D 5.4 psi Figure 12 - Pressure ...
Page 8 - IGNITOR; Figure 17 - Ignitor Replacement
Dayton Operating Instructions and Parts Manual 8 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D Maintenance (Continued) IGNITOR 1. Remove upper shell and fan guard (See page 6). 2. Remove fan (See page 6). 3. Remove 4 side cover screws with a 5/16" nut driver. Remov...
Page 9 - NOZZLE; Model
9 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® Maintenance (Continued) NOZZLE 1. Remove upper shell (See page 6). 2. Remove fan (See page 6). 3. Remove fuel and air line hoses from nozzle assembly (See Figure 18, 19,or 20). 4. Turn nozzle assembly...
Page 10 - Figure 27 - Sanding Rotor; IGNITION CONTROL ASSEMBLY; Figure 28 - Replacing Fuse; PUMP ROTOR
Dayton Operating Instructions and Parts Manual 10 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D Figure 26 - Gap Adjusting ScrewLocations NOTE : Rotate rotor one full turn to insure the gap is .003"/.004" attightest position. Adjust if needed. 10. Install blades...
Page 11 - Preventative Maintenance Schedule; How Often
11 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock canoccur. Preventative Maintenance Schedule Fuel tank Flush every 150-200 hours of operation or as ne...
Page 13 - Burner Head Assembly for All Models - Figure 30
13 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® Models 2E510E, 2E511E, 3E218E, and 3E219D Ref. Part 2E510E 2E511E No. Description Number Qty. Qty. Ref. Part 2E510E 2E511E No. Description Number Qty. Qty. Ref. Part 2E510E 2E511E No. Description Num...
Page 16 - Figure 33 - Replacement Parts Illustration for Model 3E218E
Dayton Operating Instructions and Parts Manual 16 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D Please provide following information:-Model number-Serial number (if any)-Part description and number as shown in parts list Address parts correspondence to:Grainger Parts O...
Page 17 - Replacement Parts List for Model 3E218E
17 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® (*) Standard hardware item, available locally. ( ∆ ) Not shown. (†) Not available as an assembly, see page 13. Ref. Part 2E510E 2E511E No. Description Number Qty. Qty. Ref. Part No. Description Numbe...
Page 19 - Replacement Parts List for Model 3E219D
19 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® Ref. Part No. Description Number Qty. Ref. Part No. Description Number Qty. 1 Upper Shell 098511-164 1 2 #10-16 x 1/2" Screw * 100647-01 8 3 Combustion Chamber 098512-59 1 4 Photocell Bracket 099...
Page 20 - Maintenance Kits; Figure 35 - Handle and Wheel Assembly
Dayton Operating Instructions and Parts Manual 20 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D Replacement Parts List for Handle and Wheel Group Models 3E218E and 3E219D 3 4 5 8 7 6 2 1 Ref. Part Number No. Description 3E218E 3E219D Qty. 1 Front Handle HA2203 HA2204 1...
Page 21 - Wiring Diagram; Figure 36 - Wiring Diagram for All Models; Ignition Control
21 Models 2E510E, 2E511E, 3E218E, and 3E219D Dayton Operating Instructions and Parts Manual 104447 ® Wiring Diagram Figure 36 - Wiring Diagram for All Models Blue Photocell Power Plug 120V/60Hz Ignitor Ignitor Blue White Red (3E218E and 3E219D Models) Yellow (2E510E and 2E511E Models) Gray Yellow (3...
Page 22 - Troubleshooting Chart; Corrective Action; Wiring Diagram, page 21; Symptom
Dayton Operating Instructions and Parts Manual 22 Dayton PortableOil-Fired Heaters ® 104447 2E510E, 2E511E, 3E218E, and 3E219D Troubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot.Severe burns and electrical shock can occur. Motor d...
Page 24 - NOT A UPC; LIMITED WARRANTY; LIMITATION OF LIABILITY.
Dayton Operating Instructions and Parts Manual 2E510E, 2E511E, 3E218E, and 3E219D Manufactured for Dayton Electric Mfg. Co.Niles, Illinois 60714 104447-01Rev. C12/98 Version B - For Reduction G016.J ® Dayton PortableOil-Fired Heaters NOT A UPC LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Porta...