Page 2 - Installation Manual; World wide Sales Network
Installation Manual ©2001-2007 Datalogic Mobile S.r.l. 822000381 (Rev. B) 08/07 www.mobile.datalogic.com Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 Lippo di Calderara di RenoBologna - ItalyTelephone: (+39) 051-3147011Fax: (+39) 051-3147561 World wide Sales Network available from: www.mobile.d...
Page 3 - STARGATETM
Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy STARGATE™ Ed.: 08/2007 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or ...
Page 4 - CONTENTS
CONTENTS COMPLIANCE ............................................................................................. iv Radio Compliance.........................................................................................iv FCC Compliance................................................................
Page 5 - COMPLIANCE; RADIO COMPLIANCE; for further information.
COMPLIANCE This device must be opened by qualified personnel only. RADIO COMPLIANCE Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site htt...
Page 6 - FCC COMPLIANCE; Reorient or relocate the receiving antenna.; POWER SUPPLY; or
FCC COMPLIANCE Modifications or changes to this equipment without expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful int...
Page 7 - WEEE COMPLIANCE
WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita, alla fine della sua vita utile, separatamente dai rifiuti urbani. Smaltire l’apparecchiatura in conformità alla presente Direttiva c...
Page 9 - GENERAL VIEW; connector
GENERAL VIEW A B C D E F Figure 1 - STARGATE™ Key: A) Antenna B) LED C) Power supply connector D) Reset/downloading mode button E) RS232 connector F) RS485 connectors viii
Page 10 - INTRODUCTION; DESCRIPTION OF STARGATETM
INTRODUCTION 1 1 INTRODUCTION 1.1 DESCRIPTION OF STARGATE™ STARGATE™ is a radio base station that enables a wireless network allowing data transmission between several Datalogic RF devices and an host system (standard PC, Windows based): STARGATE™ is the core component of the Datalogic STAR-System™,...
Page 11 - Features Benefits
STAR H GATE™ 1 Features Benefits • Seamless Active Roaming • Wide area coverage • Up to 2.000 RF devices supported Gryphon™ Mobile series Dragon™ Mobile series Formula 734 RF Pocket Terminals ( * ) Formula 725 RF Hand-Held Terminals ( * ) Formula 660 RF Pen Terminals ( * ) • Up to 16 STARGATE™ RF ba...
Page 12 - n. 1 wall mounting base with 2 threaded dowels and 2 screws; STATUS INDICATOR LED; Behaviour; Green
INTRODUCTION 1 1.2 PACKAGE CONTENTS The STARGATE™ Radio Base Station package contains: − n. 1 STARGATE™ Radio Base Station; − n. 1 STARGATE™ installation manual; − n. 1 STAR-Link™ installation CD-ROM; − n. 1 antenna (only for European models); − n. 1 wall mounting base with 2 threaded dowels and 2 s...
Page 13 - BUTTON; BACKUP
STAR H GATE™ 1 1.4 RESET BUTTON This button deletes all RAM data restoring the last saved configuration. By pressing it for 2.5 seconds the yellow light starts blinking and it goes on by releasing the button. This light signals that STARGATE™ has entered the firmware downloading mode. While working ...
Page 14 - INSTALLATION; impurities that could reduce adhesion
INSTALLATION 2 2 INSTALLATION 2.1 POSITIONING STARGATE™ Before connecting the STARGATE™ base station, it is first necessary to position it so that the RF transmission and reception is possible. To position STARGATE™, bear in mind the following fundamental guidelines: 1. the maximum distance between ...
Page 15 - Mounting; Screws
STAR H GATE™ 2 2.1.2 Wall Mounting Before performing the following operation, mount the fixing plate on the STARGATE™ bottom surface by means of the four screws. Then, slide the wall mounting base along the fixing plate and fix it through the set - screw. Do not screw it too tight in order to allow ...
Page 16 - Mounting holes; desire to mount STARGATETM
INSTALLATION 2 For wall mounting, fix the related plate as follows: Set - screw Mounting holes Fixing plate guide Figure 3 - Wall Mounting Base 1. Using the mounting holes on the plate as a pattern mark the wall where you desire to mount STARGATE™; 2. Drill two appropriate size holes; 3. Insert the ...
Page 17 - CONNECTIONS; CONNECTION
STAR H GATE™ 8 3 3 CONNECTIONS STARGATE™ can be connected to the PC through an RS232 or an RS485 line. It is possible to set the base station by sending the configuration of the desired connection through the software running on the PC (see par. 4.3 and par. 4.4). 3.1 RS232 CONNECTION If the require...
Page 18 - Pinout
CONNECTIONS 3 Pinout 8 1 Figure 5 - RJ45 Modular Connector 9 8 7 6 5 4 3 2 1 Figure 6 - 9-pin Female Connector The cable connecting the base station to the PC has the following pinout: 2 3 9-pin connector (female) 1 RJ45 modular connector PC side STARGATE™ side 5 5 RX TX GND 2 Figure 7 - RS232 Pinou...
Page 20 - twisted pair AWG 24 wire
CONNECTIONS 3 CAUTION To configure the STARGATE™ base station use the cable and the adapter listed in par. 3.1. For further details see par. 4.3. The RS485 bus system and the eventual power are propagated from one base station to another through a cable having the following minimum characteristics: ...
Page 21 - Supply Voltage
STAR H GATE™ 3 If connecting up to 16 STARGATE™ base stations in the same system, it is necessary to use a custom cable having two different pinouts depending on the network configuration. If each STARGATE™ present in the system is individually powered, the custom cable pinout is the following: 5 2 ...
Page 22 - Network Termination; install the antenna screwing it clockwise until
CONNECTIONS 3 If using a shielded cable, it is necessary to link the cable shields together (see Figure 12) and connect them to the earth ground in only one point. We suggest to use your PC ground (when provided) to make the connection to the earth ground. Figure 12 - Linking the Cable Shields Netwo...
Page 25 - CONFIGURING AND TESTING STAR-SystemTM; OVERVIEW; RF device address
STAR H GATE™ 4 4 CONFIGURING AND TESTING STAR-System™ 4.1 STAR-System™ OVERVIEW Two different layouts are provided depending on the application needs. Each layout may consist of a single STARGATE™ or a network of several RF base stations. An RF device is logically linked to only one STARGATE™ RF bas...
Page 29 - LOADING A SW APPLICATION ONTO AN RF TERMINAL
STAR H GATE™ 4 4.2 LOADING A SW APPLICATION ONTO AN RF TERMINAL The following procedure is not valid for STARGATE™ USA model . This example explains how to load the demo software (provided by the STAR-Link™ CD-ROM) onto an RF terminal: 1. Connect the terminal cradle to the PC COM1 by means of the se...
Page 31 - LAYOUT
STAR H GATE™ 4 4.3 RS232 LAYOUT This procedure is intended to be a step-by-step guide explaining how to configure a STARGATE™ RF Base Station by using the Visual Basic example provided in the STAR-Link™ CD-ROM and based upon the STAR-Link ActiveX. The procedure assumes the STARGATE™ RF Base Station ...
Page 35 - NOTES FOR THE PROGRAMMER
STAR H GATE™ 4 4.5 NOTES FOR THE PROGRAMMER STARGATE™ does not carry out continuous polling, but it is only enabled each time an RF device sends it a sequence of data. This means the radio channel is always free when the RF devices are not transmitting. The media access procedure used to manage the ...
Page 37 - TROUBLESHOOTING; PROBLEMS CAUSES; Set the address correctly.
STAR H GATE™ 5 5 TROUBLESHOOTING PROBLEMS CAUSES REMEDY STARGATE™ is not powered. Supply STARGATE™. The connecting cable is broken or it is not correctly connected. Check the cable is in good condition and connected correctly. During configuration a wrong communication interface has been selected. S...
Page 38 - TECHNICAL FEATURES; Electrical Features; Environmental Features
TECHNICAL FEATURES 6 6 TECHNICAL FEATURES Electrical Features Micro-controller 16bit CMOS Program memory 128 Kb Data memory 128 Kb Supply voltage 9..30 Vdc Power consumption 600 mW Radio Features European Models USA Models Working frequency 433.92 Mhz 910 Mhz Bit rate 19200 baud 36800 baud Effective...