Page 3 - Table of Contents
Installation Guide i Table of Contents Table of Contents.................................................................................................. iDatalogic Pegaso™ Powered Mobile Dock Warranty ........................................... iiiElectrical Warnings, Safety Precautions & Regu...
Page 4 - ii
ii Pegaso™ Powered Mobile Dock Technical Support ........................................................................................................ 21 Datalogic Mobile Website Support ............................................................................. 21Reseller Technical Support ......
Page 5 - iii; Datalogic PegasoTM
Installation Guide iii Datalogic Pegaso™ Powered Mobile Dock Warranty Warranty Falcon products are guaranteed against defects in materials and workmanship for the period specified at the time of sale. This warranty shall apply to FalconPortable Data Terminals (PDT's), Base Stations for the Falcon an...
Page 6 - iv; Electrical Warnings, Safety; Safety Precautions
Electrical Warnings, Safety Precautions & Regulatory Statements iv Pegaso™ Powered Mobile Dock Electrical Warnings, Safety Precautions & Regulatory Statements Safety Precautions The Datalogic Pegaso is a device suitable for both Commercial and Industrial applications, ready for installation ...
Page 7 - Chapter 1; Introduction; Manual Overview; Document Conventions
Installation Guide 1 Chapter 1 Introduction Manual Overview • Chapter 1 (this chapter) provides an introduction to the features of the Powered Mobile Dock. • Chapter 2 specifies important electrical considerations to observe when installing the unit. • Chapter 3 contains instructions for mounting. •...
Page 8 - About the Powered Mobile Dock; Features of the Powered Mobile Dock
Introduction 2 Pegaso™ Powered Mobile Dock About the Powered Mobile Dock The Powered Mobile Dock (PMD) is a rugged cradle for Pegaso PDAs, for use on mobile applications. This guide is intended to address some of the factors to consider when installing the PMD on gas, diesel, propane or electric pow...
Page 9 - Electrical Specifications:; Unpacking
Electrical Specifications: Installation Guide 3 Figure 1. Features of the Pegaso Powered Mobile Dock Electrical Specifications: • Input voltage range: +12 to +18V • Power consumption: <50 MA with no load • +5v available on COM port and as part of USB OTG Connection Unpacking Unpack the unit caref...
Page 11 - Chapter 2; Electrical Considerations; Electrostatic Build-up
Installation Guide 5 Chapter 2 Electrical Considerations Electrostatic Build-up One common characteristic of forklifts is the possibility of producing high lev-els of electrostatic voltage. Static is created by the wheels as they move about the floor and can also be generated when an operator slides...
Page 12 - Ground Contact Anti-Static Straps
Electrical Considerations 6 Pegaso™ Powered Mobile Dock Ground Contact Anti-Static Straps The recommended method of reducing static buildup is to install ground con-tacting anti-static straps or conductors to the frame of the forklift (refer to Fig-ure 3). Contact your forklift parts provider for av...
Page 13 - Electrical Accessories
Electrical Accessories Installation Guide 7 Electrical Accessories Installation of the PMD may require accessory electronic equipment for proper and safe operation. Some of this equipment may not be available through Datalogic, but could be available through your dealer, forklift parts provider, or ...
Page 14 - Electrical System Connections
Electrical Considerations 8 Pegaso™ Powered Mobile Dock Electrical System Connections This section covers electrical connection to +12V, +24V, +36V and +48V sys-tems. Connection to +12V Figure 4 illustrates a typical wiring connection for a +12 volt system. The input voltage operating range of the d...
Page 16 - NOTES
Electrical Considerations 10 Pegaso™ Powered Mobile Dock NOTES
Page 17 - Chapter 3; Mounting Options; Ram Ball Mounting Assembly
Installation Guide 11 Chapter 3 Mounting Options Ram Ball Mounting Assembly This chapter outlines the steps needed to assemble and mount the Powered Mobile Dock using the Ram Ball mount accessory. The Ram Ball and mount-ing assembly, shown in Figure 6, combine to form an extremely flexible mounting ...
Page 18 - Components, Materials and Tools; Attaching the Ram Ball to the Mobile Dock
Mounting Options 12 Pegaso™ Powered Mobile Dock Components, Materials and Tools • Four M3.5 screws for mounting Ram Ball to PMD (supplied) • Phillips head screwdriver • Ram Ball Assembly (sold separately) Attaching the Ram Ball to the Mobile Dock 1. Align the second Ram Ball with the four screw hole...
Page 19 - Final Assembly
Ram Ball Mounting Assembly Installation Guide 13 Figure 8. Ram Ball Assembly 3. Use four screws (customer supplied) to secure one of the Ram balls to the desired mounting surface. Set the other Ram ball aside to use later in the assembly process. 4. Re-attach the Ram Ball Assembly to the Ram Ball yo...
Page 20 - Inserting/Removing the Pegaso; Inserting the Pegaso in the Dock
Mounting Options 14 Pegaso™ Powered Mobile Dock Figure 9. Installing the Mobile Dock Assembly on the Mount 2. Loosen the Adjustment Knob slightly to tilt the Mobile Dock to the desired mounting angle. Re-tighten the Adjustment Knob securely. 3. Route and connect all cables (see “Power and Peripheral...
Page 21 - Removing the Pegaso from the Dock
Inserting/Removing the Pegaso Installation Guide 15 Figure 10. Inserting the Pegaso into the Powered Mobile Dock Insertion of the Pegaso in the Dock is complete. Removing the Pegaso from the Dock To remove the Pegaso from the Dock: 1. Grasp the Pegaso PDA with one hand, while pushing the Release But...
Page 23 - Chapter 4; Power and Peripheral; Connections on the Dock; Power Connection
Installation Guide 17 Chapter 4 Power and Peripheral Device Connections This chapter describes connection of peripheral devices that are provided with or available for the Pegaso PMD system. For more on power connections, see “Electrical Considerations” starting on page 5. Connections on the Dock Fi...
Page 24 - Battery Charging; COM Port Connection
Power and Peripheral Device Connections 18 Pegaso™ Powered Mobile Dock Also refer to “Electrical Considerations” starting on page 5 for complete infor-mation and wiring diagrams detailing power connection. Battery Charging The PMD provides battery charging for the Pegaso PDA when powered. COM Port C...
Page 25 - USB Connection
Installation Guide 19 USB Connection The Pegaso Powered Mobile Dock includes a USB OTG connection (shown in Figure 12 on page 17) to allow the Pegaso PDA to communicate with peripherals such as handheld scanners and printers. The USB port is automat-ically configured to function as a USB host or cli...
Page 27 - Appendix A; Hardware Troubleshooting; Issues with Power to the Dock; Technical Support; Datalogic Mobile Website Support; Reseller Technical Support
Installation Guide 21 Appendix A Troubleshooting Hardware Troubleshooting Issues with Power to the Dock • Ensure that the power connector is pushed securely into the power plug. • When power to the unit is turned on, a light will appear on the Dock. Refer to the Pegaso Quick Reference Guide (QRG) fo...
Page 29 - Appendix B; Overview
Installation Guide 23 Appendix B Accessories and Peripherals Overview Installation of the PMD may require accessory electronic equipment for proper and safe operation. Contact your reseller or Datalogic sales for informa-tion about availability. Table 3. Pegaso Mobile Dock Accessories Item Descripti...
Page 33 - Index
Installation Guide 27 Index +12V and +24V Systems 8 +36V and +48V Systems 9 A Accessories 23 Overview 23 Attaching the Pegaso to a Dock 14 D Document Conventions 1 Overview 1 E Electrical Accessories 7 AC Power Adapter 8 DC Conditioner 7 DC/DC Converter 7 Delay Timer 7 Noise Spike/RF Filter 7 Electr...