iii CONTENTS 1 GENERAL INFORMATION ................................... 1 1.1 F732 W IZARD™ Terminal Description ................. 1 1.2 Downloading EasyGen™ Demo............................ 3 1.3 Application Development Programs ...................... 3 1.4 Purpose of the Manual .......................
Page 6 - iv
Page 7 - GENERAL INFORMATION; GENERAL; F732 WIZARDTM TERMINAL DESCRIPTION
GENERAL INFORMATION 1 Ed.: 06/01 1 1 GENERAL INFORMATION 1.1 F732 WIZARD™ TERMINAL DESCRIPTION For vast majority of small businesses and retailers, thecomplete Formula W izard™ package represents thesimplest and most cost-effective solution for entering theworld of bar code data acquisition. The For...
Page 9 - DOWNLOADING EASYGENTM DEMO
GENERAL INFORMATION 1 Ed.: 06/01 3 The F732 terminal has an LCD graphic display of 16characters by 4 lines plus a line in the upper part of thedisplay for the programmable icons: FORMULA 732 WIZARDPOCKET LASER TERMDATALOGIC S. P. A.4 LINESx16 CHARS Time The battery charge status The icons which can ...
Page 10 - EasyGenTM Application Generator; PURPOSE OF THE MANUAL; For the everyday user:
F732 WIZARD™ 1 4 Ed.: 06/01 EasyGen™ Application Generator By using the EasyGen™ software, developers can easilyand quickly build personalized applications of averagecomplexity in a W indows environment. • EasyGen™ (Easy Application Generator Package)* order nr. 94A104850. * 32-bit software for Micr...
Page 11 - CONTENTS OF PACKING; The F732 terminal package includes:; CAUTION
GENERAL INFORMATION 1 Ed.: 06/01 5 1.5 CONTENTS OF PACKING The F732 terminal package includes: − nr. 1 F732 terminal complete with batteries; − nr. 1 cradle F952 with power supply; − nr. 1 cable 90A054000 for serial connection; − nr. 1 user's manual − nr. 1 test chart CAUTION Remove all components f...
Page 12 - IDENTIFICATION
F732 WIZARD™ 1 6 Ed.: 06/01 1.6 TERMINAL IDENTIFICATION SE R 12 345 67 89 CO D 9 414 04 020 M O D F 732 /B 12 8K D at al og ic S pA 00 /0 1 CA U TIO N SER 123456789 COD 941404020 MOD F732/B 128K Datalogic SpA 00/01 Serial number Production Code Model identification
Page 13 - SAFETY REGULATIONS; SAFETY; NOTE; GENERAL SAFETY RULES; Do not submerge the F732 terminal in liquid products.
SAFETY REGULATIONS 2 Ed.: 06/01 7 2 SAFETY REGULATIONS NOTE Read this manual carefully beforeperforming any type of connection or repairon the F732 terminal. The user is responsible for any damagescaused by incorrect use of the equipment orby inobservance of the indication suppliedin this manual. 2....
Page 14 - SAFETY; Laser beam output window
F732 WIZARD™ 2 8 Ed.: 06/01 2.2 LASER SAFETY The laser light is visible to the human eye and is emittedfrom the window indicated in the figure. S E R 12 345 67 89 C O D 9 414 040 20 M O D F 73 2/ B 128 K D at alo gi c Sp A 00 /0 1 CA UT IO N AVOID EXPOSURE-LASER LIGHT IS EMITTED FROM THIS APERTURE 6...
Page 15 - ENGLISH
SAFETY REGULATIONS 2 Ed.: 06/01 9 I D F E LUCE LASERNON FISSAREIL FASCIOAPPARECCHIOLASER DICLASSE 2MASSIMAPOTENZAD'USCITA:LUNGHEZZAD'ONDAEMESSA:CONFORME AEN 60825(1993) LASERSTRAHLUNGNICHT IN DENSTRAHL BLICKENPRODUKT DERLASERKLASSE 2MAXIMALEAUSGANGSLEISTUNG:W ELLENLÄGE:ENTSPR. EN 60825(1993) RAYON L...
Page 16 - ITALIANO; ATTENZIONE; DEUTSCH
F732 WIZARD™ 2 10 Ed.: 06/01 ITALIANO Le seguenti informazioni vengono fornite dietro direttivedelle autorità internazionali e si riferiscono all’uso correttodel terminale.NORMATIVE STANDARD PER LA SICUREZZA LASERQuesto prodotto risulta conforme alle normative vigenti sullasicurezza laser alla data ...
Page 17 - ACHTUNG; FRANÇAIS; ATTENTION
SAFETY REGULATIONS 2 Ed.: 06/01 11 ACHTUNG Jegliche Änderungen am Gerät sowieVorgehensweisen, die nicht in dieserBetriebsanleitung beschreiben werden,können ein gefährliches Laserlichtverursachen. Das Produkt benutzt eine Laserdiode. Obwohl zur Zeitkeine Augenschäden von kurzen Einstrahlungen bekann...
Page 18 - ESPAÑOL; ATENCIÓN
F732 WIZARD™ 2 12 Ed.: 06/01 ESPAÑOL Las informaciones siguientes son presentadas enconformidad con las disposiciones de las autoridadesinternacionales y se refieren al uso correcto del terminal.NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSEREste aparato resulta conforme a las normativas vigentes desegu...
Page 19 - THE USER
SAFETY REGULATIONS 2 Ed.: 06/01 13 2.3 FCC COMPLIANCE - INFORMATION FOR THE USER CAUTION This device complies with PART 15 of theFCC Rules. Operation is subject to thefollowing two conditions: (1) This devicemay not cause harmful interference, and(2) this device must accept anyinterference which may...
Page 20 - CONNECTION
F732 WIZARD™ 3 14 Ed.: 06/01 3 CONNECTION 3.1 CRADLE To make the F732 terminal operative, it is necessary toinsert it in the Formula 952 Transceiver charger cradlewhich has previously been connected to the power supplyand to a host computer with an available RS-232 serial line.
Page 21 - CONNECTION; The following figure describes the F952 cradle:; RJ connector for connection to the host computer
CONNECTION 3 Ed.: 06/01 15 The following figure describes the F952 cradle: A B P OW E R + 9V RS -2 32 P ORT S/N 2019500252 Mod. F952 Code n. 140901450 Datalogic SpA 99/10 C D E Key:A) Cradle on/off switch B) Two color LED: Continuous green = F732 terminal not inserted orcharge level being maintained...
Page 22 - CONNECTION TO THE HOST COMPUTER; Connection; - Connect the serial port of the host computer to cable
F732 WIZARD™ 3 16 Ed.: 06/01 3.2 CONNECTION TO THE HOST COMPUTER CAUTION Before proceeding with this phase, makesure that both the computer and the F732terminal are switched off. 3.2.1 RS-232 Connection To connect the F952 cradle to the host computer, proceedas indicated below: 1- Connect the serial...
Page 23 - Host computer
CONNECTION 3 Ed.: 06/01 17 Power Supply 94A054000 ( 94A054010) A B C Key: A) Host computer B) Single cradle F952 C) Power supply
Page 24 - CABLES
F732 WIZARD™ 3 18 Ed.: 06/01 3.3 CONNECTION CABLES Several types of cables are available depending on the typeof computer and connection.The following cables are listed with their order number. RS-232 Connection with PC/AT or compatible:cable 94A054000 (included with terminal) TX RTS GND CTS RX 1 ...
Page 25 - USE AND OPERATION
USE AND OPERATION 4 Ed.: 06/01 19 4 USE AND OPERATION W hen an EasyGen™ application program is loaded ontothe F732 terminal (either a Demo example or an applicationdeveloped with EasyGen™ for Formula) to launch it, it isnecessary to extract the F732 terminal from the cradle andpress <SHIFT> an...
Page 26 - , and the time icon will
F732 WIZARD™ 4 20 Ed.: 06/01 4.1 LOADING APPLICATION PROGRAMS If you are using application programs for EasyGen™ (seepar. 1.2 or par. 1.3) refer to chapter 6 of the EasyGen™User's Manual. If you are using applications developed with DS for Formula(see par. 1.3) refer to the "Tools" paragraph...
Page 27 - DESCRIPTION OF KEYS; “Select” mode
USE AND OPERATION 4 Ed.: 06/01 21 4.3 DESCRIPTION OF KEYS Although EasyGen™ for Formula allows assigningcustomized functions to function keys, there are somestandard functions common to all applications because theyare implemented in the interpreter software. ATTENTION Refer to chapter 6 "EasyGe...
Page 30 - DOWNLOADING DATA TO HOST
F732 WIZARD™ 4 24 Ed.: 06/01 4.4 DOWNLOADING DATA TO HOST Data can be downloaded from the terminal to the host PC indifferent ways, depending on the application loaded: − automatically, by simply inserting the terminal into thecradle; − by direct operator intervention on the terminal or hostcomputer...
Page 31 - MAINTENANCE; CHARGING THE BATTERIES; . The information provided
MAINTENANCE 5 Ed.: 06/01 25 5 MAINTENANCE NOTE Rechargeable battery packs (NiCd) are notinitially charged. Therefore the firstoperation to perform is to charge them inthe appropriate cradle. See chapter 3 andthe following paragraph "Charging theBatteries". 5.1 CHARGING THE BATTERIES Battery ...
Page 33 - REPLACING THE BATTERIES; To replace the batteries correctly, proceed as follows.
MAINTENANCE 5 Ed.: 06/01 27 5.2 REPLACING THE BATTERIES ATTENTION Before proceeding, ensure that theterminal is switched off and that the datait contains has been downloaded ontothe host computer. To replace the batteries correctly, proceed as follows. 1- Turn over the F732 terminal and removethe tw...
Page 34 - CLEANING THE TERMINAL
F732 WIZARD™ 5 28 Ed.: 06/01 3- Replace the battery pack, making sure thebatteries are inserted inthe right direction asindicated on the cover. 4- Close the battery cover and tighten the screws. NOTE Dispose of used batteries in accordancewith the relevant laws in force. 5.3 CLEANING THE TERMINAL Cl...
Page 35 - TROUBLESHOOTING; PROBLEM; and
TROUBLESHOOTING 6 Ed.: 06/01 29 6 TROUBLESHOOTING PROBLEM CAUSE REMEDY Flat batteries. Rechargeterminal. W hen the<SCAN> buttonis pressed theterminal does notcome on. Batteriescompletely flat orbroken. Replacebatteries. Flat batteries. Rechargeterminal. W hen the<SCAN> buttonis pressed, ...
Page 37 - TECHNICAL FEATURES; TECHNICAL; Optical
TECHNICAL FEATURES 7 Ed.: 06/01 31 7 TECHNICAL FEATURES Optical Light source laser scanner, VLD source,670 nm Scan rate 36 ± 3 scan/sec Minimum resolution 0.15 mm (5.90 mils) Skew angle ± 65° Pitch angle ± 55° Depth of field 3 to 70 cm (1.18 to 27.55 in)(depends on code density) Electrical Micro-con...
Page 39 - Programming
TECHNICAL FEATURES 7 Ed.: 06/01 33 Programming Operating modes bootstrap loader applicationprogram Transmission F952 interface via optical transceiver with serialprotocol Cradle-Host interface RS-232 Transmission speed 300 to 19200 bit/sec Transmission protocol program-definable Transmission modes f...