Page 2 - CONTENTS; NOTE; SERVICES AND SUPPORT; PRODUCTS; and; - Authorised Repair Centres; E-mail form and listing of Datalogic Subsidiaries
CONTENTS DS6300-100-010 MASTER/SLAVE MODEL ...........................................................................................................1 DS6300-100-011 PROFIBUS MODEL .....................................................................................................................8...
Page 3 - Optical Model; Avalanche photodiode
DS6300 MASTER/SLAVE MODEL 1 DS6300-100-010 MASTER/SLAVE MODEL Figure A Laser Beam Output Window 1 Figure B Programming Keypad 1 Phase On LED (Yellow) 3 TX Data LED (Green) 2 Power On LED (Red) 4 LCD Display 5 Figure C Main/Aux. Interface 25-pin D-sub Male Connector 1 Lonworks 9-pin Male Connector 2 ...
Page 4 - Std Models; Electrical Connections:
DS6300 MASTER/SLAVE MODEL 2 SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Operating Readable Codes Code 39 standard Temperature 0° to +40 °C (+32° to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & F...
Page 5 - -pin Local Lonworks Connectors; Network Termination:; BTK-6000 Network Terminator; Master; to; Slave
DS6300 MASTER/SLAVE MODEL 3 The details of the connector pins are indicated in the following table: 25-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Tr...
Page 6 - Pass Through Layout; Main Serial Interface
DS6300 MASTER/SLAVE MODEL 4 Connectivity: Point-to-Point Layout * P.S. (Presence Sensor) connected to External Trigger/PS input. Pass Through Layout EN T < < EN T < < 1 2 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to External Trigger/PS input. DS4...
Page 7 - Multiplexer Layout; RS485 HD Main Interface; RS232 Master/Slave Layout
DS6300 MASTER/SLAVE MODEL 5 Multiplexer Layout EN T < < EN T < < 1 RS485 HD Main Interface * P.S. (Presence Sensor) connected to External Trigger/PS input. RS232 Master/Slave Layout EN T < < EN T < < 1 Main Serial Interface 2 Auxiliary Serial Interface * P.S. (Presence Sensor...
Page 8 - Small Synchronized Network with 2 Readers; C-BOX 100 modified to accept scanner power.; C-BOX 100 modified to accept scanner power.
DS6300 MASTER/SLAVE MODEL 6 Local Lonworks Network Small Synchronized Network with 2 Readers * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 100 modified to accept scanner power. *** Encoder connected to IN2/ENC input. Local Lonworks Network Small Synchronized Network with ...
Page 9 - Large Synchronized Network; Encoder connected to ENC input.; Large Synchronized Network with DX6X00 and DS6XXX Scanners
DS6300 MASTER/SLAVE MODEL 7 Large Synchronized Network * P.S. (Presence Sensor) connected to External Trigger/PS input. ** Encoder connected to ENC input. Large Synchronized Network with DX6X00 and DS6XXX Scanners * **
Page 10 - Lonworks; lines by 16 characters LCD
DS6300 PROFIBUS MODEL 8 DS6300-100-011 PROFIBUS MODEL Figure A Laser Beam Output Window 1 Figure B Programming Keypad 1 Phase On LED (Yellow) 3 TX Data LED (Green) 2 Power On LED (Red) 4 LCD Display 5 Figure C Profibus 9-pin Female Connector (white) 1 Lonworks 9-pin Female Connector 2 Main/Aux. Inte...
Page 13 - Fieldbus; Fieldbus
DS6300 PROFIBUS MODEL 11 Connectivity: Point-to-Point Layout * P.S. (Presence Sensor) connected to External Trigger/PS input. Pass Through Layout EN T < < EN T < < 1 2 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to External Trigger/PS input. Remote...
Page 14 - Fieldbus Small Synchronized Network
DS6300 PROFIBUS MODEL 12 Local Lonworks Network Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 100 modified to accept scanner power. *** The Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder c...
Page 15 - Ethernet
DS6300 ETHERNET MODEL 13 DS6300-100-012 ETHERNET MODEL Figure A Laser Beam Output Window 1 Figure B Programming Keypad 1 Phase On LED (Yellow) 3 TX Data LED (Green) 2 Power On LED (Red) 4 LCD Display 5 Figure C RJ45 Modular Connector for Ethernet Interface 1 Lonworks 9-pin Female Connector 2 Main/Au...
Page 20 - DeviceNet
DS6300 DEVICENET MODEL 18 DS6300-100-015 DEVICENET MODEL Figure A Laser Beam Output Window 1 Figure B Figure C Programming Keypad 1 Phase On LED (Yellow) 3 TX Data LED (Green) 2 Power On LED (Red) 4 LCD Display 5 Main/Aux. Interface 26-pin D-sub Male Connector 1 Lonworks 9-pin Female Connector 2 Dev...
Page 25 - DS6300 OSCILLATING MIRROR MODEL; Figure A; assure at least 10°; Oscillating Mirror Skew Angle
DS6300 OSCILLATING MIRROR MODEL 23 DS6300-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output Window 1 Oscillating mirror models are used when coverage of a large reading area is required, mainly in picket fence applications. The DS6300 scanner mounts a dedicated optic head with integrated o...
Page 26 - Oscillating Mirror Maximum Aperture and Asymmetry; Aperture
DS6300 OSCILLATING MIRROR MODEL 24 The mirror can be deflected up to 40°. Oscillation with respect to the output window median axis is asymmetrical (see figure below). 40° 37 .5 ° 0° -2 .5 ° Oscillating Mirror Maximum Aperture and Asymmetry By configuring the oscillating speed up to the maximum valu...
Page 27 - COMMON FEATURES
COMMON FEATURES 25 COMMON FEATURES C-BOX 100 Pinout for DS6300: The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DS6300 reader is connected in a network by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Power 1, 3, 5 VS 2, 4, 6 GND 7,...
Page 28 - Mechanical Installation:; ST-237 Mounting Bracket Overall Dimensions; DS6300 Oscillating Mirror Model Overall Dimensions
COMMON FEATURES 26 Mechanical Installation: The DS6300 reader can be positioned and installed in the best way possible as a result of the Step-A-Head TM feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and conne...
Page 29 - Typical Installations:; ATTENTION; Conveyor Direction
COMMON FEATURES 27 Typical Installations: Standard Installation The DS6300 scanner is mounted on the ST-237 106° mounting bracket which guarantees a built-in Skew angle ( S in the figure below) of 16° with respect to the frame plane (typically the Skew angle should be between 10° - 20°). This avoids...
Page 30 - WARNING; Display Visualization; xxx
COMMON FEATURES 28 Focus Adjustment: The DS6300 provides a manual adjustment of the optics to optimize the reading performance by choosing the best focus between two extreme positions. The focus adjustment is continuous and not by step; thus, allowing an optimum adjustment around the selected positi...
Page 31 - the; Focus Adjustment Screw; ANSI Grade B minimum
COMMON FEATURES 29 7) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode. Focus Adjustment Screw NOTE The reader display shows the focus position only when the las...
Page 33 - Focus
COMMON FEATURES 31 Reading Diagrams: In the following reading diagrams (0,0) is the center of the laser beam output window. DS6300-100-0XX – Resolution: 0.20 mm/8 mils CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 4 2 0 6 (in) 0 6 12 ...
Page 37 - RX; How To Build A Simple Interface Test Cable:; PC; Figure B
COMMON FEATURES 35 User Interface: RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable incl...
Page 38 - Figure C; AVOID EXPOSURE; LASER RADIATION IS EMITTED FROM THIS APERTURE; Laser Safety Label for Oscillating Mirror and Standard Models; Power Supply
COMMON FEATURES 36 Figure C Laser Safety Label 1 The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exp...
Page 39 - DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS6300-XXX-XXX, Laser Scanner; e tutti i suoi modelli and all its models et tous ses modèles ...