Page 2 - INSTALLATION MANUAL
Page 3 - DS4300-XXXX, Laser Scanner and all its models
We DATALOGIC S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product DS4300-XXXX, Laser Scanner and all its models to which this declaration relates is in conformity with the following standards or other normativedocuments EN 55022, Aug...
Page 4 - iii; CONTENTS; GUIDE TO INSTALLATION
iii CONTENTS GUIDE TO INSTALLATION ............................................................... v General View ..................................................................................... vi SAFETY PRECAUTIONS ................................................................viii Laser Saf...
Page 5 - iv; READING FEATURES
iv 3 READING FEATURES ....................................................................3.1 3.1 Advanced Code Reconstruction ......................................................3.1 3.1.1 Tilt Angle for Advanced Code Reconstruction .................................3.2 3.2 Decoding Capacity in Lin...
Page 6 - NOTE; The installation is now complete.
v GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessaryfor complete installation of the DS4300 scanner. 1) Read all information in the section "Safety Precautions" at the beginning of this manual. 2) Correctly position and mount the scanner for b...
Page 7 - General View; Figure A
vi DS4300 General View 1 11 10 9 8 2 7 6 5 4 3 Figure A Cable with 25-pin connector Mounting holes Good Read LED External Trigger LED Ready LED 1 2 4 5 3 10 11 6 Data TX LED Laser beam output window 8 7 Warning Label Warning and Classification labels Accessory mounting holes 9 Laser active LED
Page 8 - vii; Figure B
vii DS4300 General View 11 10 9 8 2 1 7 6 5 4 3 Figure B Cable with junction box Mounting holes Good Read LED External Trigger LED Ready LED 1 2 4 5 3 10 11 6 Data TX LED Laser beam output window 8 7 Warning Label Warning and Classification labels Accessory mounting holes 9 Laser active LED
Page 9 - viii; SAFETY PRECAUTIONS; LASER SAFETY
viii SAFETY PRECAUTIONS LASER SAFETY The following information is provided to comply with the rules imposed byinternational authorities and refers to the correct use of the DS4300 scanner. Standard Regulations This scanner utilizes a low-power laser diode. Although staring directly at thelaser beam ...
Page 10 - ix; and; Warning and device class labels; Laser diode class label
ix W arning labels indicating exposure to laser light and the device classificationare applied onto the body of the scanner (Figure A/B, 8 and 7 ). DATALOGIC S.p.A. Via Candini, 240012 LIPPO DI CALDERARA (BO) ITALY Model No. Serial No. Volt Amp. Manufactured This product conforms to the applicable r...
Page 11 - POWER SUPPLY
x POWER SUPPLY For Model DS4300-1000: This device is intended to be supplied by a ULListed Direct Plug-In Power Unit marked "Class 2", output rated 10-30 V,minimum 0.55 A.This device may also be supplied by a UL Listed Power Unit with a "Class 2"or LPS power source which supplies pow...
Page 12 - DATALOGIC; GENERAL; ACRTM
DATALOGIC DS4300 General Features - 1.1 1 GENERAL FEATURES 1.1 INTRODUCTION The DS4300 is a compact laser scanner complete with decoder whichemploys Datalogic’s powerful ACR™ (Advanced Code Reconstruction) technology. It was designed to satisfy the most demanding requirementsassociated with omni-dir...
Page 14 - ). A green LED on the same side indicates the laser is active; READY; are to attach accessories
DATALOGIC DS4300 General Features - 1.3 Electrical connection is provided through a cable on the side of the reader;this cable is terminated with a 25-pin connector (25-pin connector models,see paragraph 1.3, Figure A, 1 ) or by a junction box (junction box models, see paragraph 1.3, Figure B, 1 ). ...
Page 15 - MODELS; Optical Resolution; Cable Termination
DS4300 DATALOGIC 1.4 - General Features 1.3 AVAILABLE MODELS The DS4300 scanner is available in versions that differ in regard to thefollowing characteristics: • Optical Resolution • Cable Termination The following models are therefore available: DS4300 - 100X Optical Resolution 1 = Standard Resolut...
Page 16 - INSTALLATION; manual
DATALOGIC DS4300 Installation - 2.1 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS4300 reader and all the parts supplied with the equipmentare present and intact when opening the packaging; the list of parts includes: 1) DS4300 reader with cable 2) Installation manual 3) Barcode test chart 4...
Page 17 - INSTALLATION; Refer to paragraph 2.5 for correct positioning.
DS4300 DATALOGIC 2.2 - Installation 2.2 MECHANICAL INSTALLATION DS4300 can be installed to operate in different positions. The four screwholes (M4 x 5) on the body of the reader are for mechanical fixture (FigureA/B, 2 ). The diagram below gives the overall dimensions of the scanner and may beused f...
Page 18 - JUNCTION BOX INSTALLATION
DATALOGIC DS4300 Installation - 2.3 2.3 JUNCTION BOX INSTALLATION The junction box provides a passive connection between your scanner andthe outside world in a fast and practical way. It represents an alternative tothe 25-pin connector models. Figure 2.3 shows the basic layout of DS4300using the jun...
Page 19 - ) Open the junction box by unscrewing the 4 cover screws.
DS4300 DATALOGIC 2.4 - Installation The junction box is designed to be mounted to a panel of metal, plastic orother appropriate material using the mounting screws provided in thepackage. To do this: 1) Open the junction box by unscrewing the 4 cover screws. If necessary, using the two mounting holes...
Page 20 - Junction Box Electrical Connections; Figure 2.6 - System cable connections to the junction box
DATALOGIC DS4300 Installation - 2.5 2.3.2 Junction Box Electrical Connections The connection and wiring procedure for the junction box is described asfollows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To co...
Page 21 - Pin; Junction Box
DS4300 DATALOGIC 2.6 - Installation Figure 2.7 - Junction box connector and pinout To allow connection of an NEC Class 2Power Unit, use a correct female plugadapter. Figure 2.8 - NEC Class 2 Power unit connections * The signals on pins 24, 25 and 26 are repeatedon pins 29, 30 and 31 to facilitate ne...
Page 22 - Figure 2.9 - Scanner cable connections to the junction box; seal is fitted correctly between the parts of the housing.
DATALOGIC DS4300 Installation - 2.7 4) After wiring the junction box and while the scanner is unplugged from the power supply, place the Scanner cable so that the rubber seal fits into thecutout in the housing of the junction box and plug the 24-pin connectorinto connector J1 on the PCB inside the j...
Page 23 - ELECTRICAL CONNECTIONS FOR 25-PIN MODELS
DS4300 DATALOGIC 2.8 - Installation 2.4 ELECTRICAL CONNECTIONS FOR 25-PIN MODELS 25-pin connector models (see paragraph 1.3) are equipped with a cableterminated by a 25-pin D-sub connector for connection to the power supplyand input/output signals. The details of the connector pins are indicated int...
Page 24 - USER INTERFACE; Figure 2.12 - Power supplied using the jack connector; It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
DATALOGIC DS4300 Installation - 2.9 2.4.1 Power Supply Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host (Figure 2.11): DS4300 13 25 VS GND 1 CHASSIS Earth Ground USER INTERFACE CHASSIS GND V+ (10 - 30 Vdc) Figure 2.11 - Power...
Page 26 - Figure 2.13 - RS232 main interface connections
DATALOGIC DS4300 Installation - 2.11 RTS/CTS HARDWARE HANDSHAKING ENABLED DS4300 USER INTERFACE 7 SGND Main SGND RTS232 4 DCD CTS232 5 DTR RX232 3 TXD TX232 2 RXD Figure 2.13 - RS232 main interface connections Figure 2.14 - RS232 control signals The RTS232 and CTS232 signals control data transmissio...
Page 28 - MULTIPLEXER
DATALOGIC DS4300 Installation - 2.13 RS485 Half-Duplex The RS485 half-duplex (3 wires + shield) interface is used for polledcommunication protocols. It can be used for Multidrop connections in a master/slave layout or with aDatalogic Multiplexer, (see par. 2.6.4 and 2.6.5). The following pins of the...
Page 29 - CHASSIS; three wires; Figure 2.17 - DS4300 multidrop connection to a Multiplexer
DS4300 DATALOGIC 2.14 - Installation The figure below shows a multidrop configuration with DS4300 scannersconnected to a Multiplexer. 1 1 CHASSIS # 1 RTX485+ RTX485- SGND Main # 0 max. 1200 m. three wires + shield 7 4 2 7 4 2 120 Ohm MULTIPLEXER RTX485+ RTX485- RS485REF SHIELD 1 120 Ohm DS4300 DS430...
Page 30 - current loop output
DATALOGIC DS4300 Installation - 2.15 20 mA Current Loop (INT-24 Accessory Only) W hen the INT-24 accessory board is installed, the DS4300 is equipped witha 20 mA active current loop interface. The following pins of the 25-pin connector are used for the connections: Pin Name Function 4 CLOUT- current...
Page 31 - Figure 2.19 - RS232 auxiliary interface connections; Winhost Help On Line)
DS4300 DATALOGIC 2.16 - Installation 2.4.3 Auxiliary RS232 Interface The auxiliary serial interface is used exclusively for RS232 point-to-pointconnections. The parameters relative to the auxiliary interface (baud rate, data bits, etc.)as well as particular communication modes such as Local Echo can...
Page 32 - The pinouts are indicated below:; ), is on when the External Trigger signals the active reading phase; Figure 2.20 - Input NPN command using external power; Figure 2.21 - Input NPN command using DS4300 power
DATALOGIC DS4300 Installation - 2.17 The pinouts are indicated below: Pin Name Function 18 EXT TRIG+ external trigger + 19 EXT TRIG- external trigger - 6 IN1+ input 1 + 10 IN1- input 1 - 14 IN2+ input 2 + 15 IN2- input 2 - The EXT TRIG inputs are used in the ON-Line Operating mode and tells thescann...
Page 33 - Figure 2.22 - Input PNP command using external power; Figure 2.23 - Input PNP command using DS4300 power; The electrical features of the inputs are:
DS4300 DATALOGIC 2.18 - Installation 18/6/14 + 19/10/15 - + 5V DS4300 USER INTERFACE V Signal Ground 30 Vdc max. Vext Figure 2.22 - Input PNP command using external power 18/6/14 + 19/10/15 - USER INTERFACE DS4300 VS 9 25 GND V Signal + 5V Figure 2.23 - Input PNP command using DS4300 power The elect...
Page 34 - These outputs are both level or pulse configurable.
DATALOGIC DS4300 Installation - 2.19 2.4.5 Outputs The following pins are present on the 25-pin connector of the scanner: Pin Name Function 8 OUT1+ output 1 + 22 OUT1- output 1 - 11 OUT2+ output 2 + 12 OUT2- output 2 - The meaning of the two outputs OUT1 and OUT2 can be defined by the user(No Read, ...
Page 36 - LAYOUTS; Terminal; Main serial interface
DATALOGIC DS4300 Installation - 2.21 2.6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. Dottedlines in the figures refer to optional hardware configurations within theparticular layout. These layouts also require the correct setup of the software configuration...
Page 37 - Host
DS4300 DATALOGIC 2.22 - Installation 2.6.2 Pass Through Pass through mode allows two or more devices to be connected to a singleexternal serial interface. Each DS4300 transmits the messages received by the auxiliary interfaceonto the main interface. All messages will be passed through this chain to ...
Page 39 - Auxiliary serial interface
DS4300 DATALOGIC 2.24 - Installation 2.6.4 RS485 Master/Slave The RS485 master/slave connection is used to collect data from severalscanners to build either an omni-directional or a multi-sided reading system;there can be one master and up to 5 slaves connected together. The Slave scanners are conne...
Page 40 - RS485 HD Main interface
DATALOGIC DS4300 Installation - 2.25 NOTE The auxiliary serial interface of the slave scanners can be usedin Local Echo communication mode to control any singlescanner (visualize collected data) or to configure it using theWinHost utility or Host Mode Programming procedure. The termination resistors...
Page 42 - READING; ADVANCED CODE RECONSTRUCTION
DATALOGIC DS4300 Reading Features - 3.1 3 READING FEATURES 3.1 ADVANCED CODE RECONSTRUCTION The traditional way of barcode reading could be called "Linear Reading". Inthis case, the laser beam crosses the barcode symbol from its beginning toits end as shown in Figure 3.1. Laser Beam Figure 3...
Page 43 - Tilt Angle for Advanced Code Reconstruction; max
DS4300 DATALOGIC 3.2 - Reading Features 3.1.1 Tilt Angle for Advanced Code Reconstruction The most important parameter in Advanced Code Reconstruction is thevalue of the maximum tilt angle ( α maximum) under which the code reconstruction process is still possible. W e define the Tilt angle as the an...
Page 44 - DECODING CAPACITY IN LINEAR MODE
DATALOGIC DS4300 Reading Features - 3.3 3.2 DECODING CAPACITY IN LINEAR MODE W hen in Linear Reading mode, the number of reads performed by theDS4300 and therefore the decoding capacity, is influenced by the followingparameters: • number of scans per second • code motion speed • label dimensions • s...
Page 45 - These symbols signify:
DS4300 DATALOGIC 3.4 - Reading Features For example, the DS4300 (800 scans/sec.), for a 25 mm high code movingat 1250 mm/s performs: [(25/1250) * 800] - 2 = 14 effective scans. 3.2.2 Picket Fence Mode FW LW Code motion moving at LS speed Laser Beam DS4300 Figure 3.6 - "Picket Fence" scanning...
Page 46 - C ambient temperature, depending on the conditions in the
DATALOGIC DS4300 Reading Features - 3.5 3.3 PERFORMANCE The DS4300 scanner reads codes with densities from 0.20 mm (8 mils) to1.00 mm (40 mils) in the zone between 50 mm (1.9 in) and 400 mm (15.7 in)from the emission window. DS4300 can be optimized for reading high density codes (between 0.20 mm(8 m...
Page 47 - DIAGRAMS; Test Codes used
DS4300 DATALOGIC 3.6 - Reading Features 3.4 READING DIAGRAMS The following diagrams show the reading distance for barcodes with differentdensities. DS4300-100X (Code Resolution Standard) (31 mils) 0.50 mm ≥ 0.80 mm (20 mils) (24 mils) 0.60 mm NOTE: (0,0) is the center of the laser beam output window...
Page 50 - MAINTENANCE; WARNING
DATALOGIC DS4300 Maintenance - 4.1 4 MAINTENANCE 4.1 CLEANING Clean the laser beam output window periodically for continued correctoperation of the reader. Dust, dirt, etc. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft m...
Page 52 - TECHNICAL; ELECTRICAL FEATURES; Power; OPTICAL FEATURES
DATALOGIC DS4300 Technical Features - 5.1 5 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply voltage 10 to 30 Vdc Power consumption max. 5.5 W Serial Interfaces Main RS232, RS485 full-duplex, RS485 half-duplex (20 mA C.L. only with INT-24 accessory ) Auxiliary RS232 Baud rates 1200 to 115200 Inpu...
Page 53 - SOFTWARE FEATURES; ENVIRONMENTAL FEATURES
DS4300 DATALOGIC 5.2 – Technical Features SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC • Code 93 • 2/5 Interleaved • Code 128 • Code 39 • EAN 128 • Codabar • Pharmacode CODE SELECTION up to six codes during one reading phase DECODING SAFETY can enable multiple good reads of same code HEADER...