Page 2 - PRODUCTS
DS2100N QUICK GUIDE 2 UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo m...
Page 3 - STEP 1 – CONNECT THE SYSTEM
DS2100N QUICK GUIDE 3 STEP 1 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 1. In this layout the data is transmitted to the Host on the main serial interface. In Local Echo communication mode, the RS232 auxiliary interface can be...
Page 5 - STEP 2 – MOUNT AND POSITION THE SCANNER; shown in the figures below.; Tilt 0° and Pitch 0°; scanner should be positioned at.
DS2100N QUICK GUIDE 5 STEP 2 – MOUNT AND POSITION THE SCANNER 1. To mount the DS2100N, use the mounting bracket to obtain the most suitable position for the reader as shown in the figures below. Figure 3 - Positioning with Mounting Bracket 2. When mounting the DS2100N take into consideration these t...
Page 6 - STEP 3 – X-PRESSTM CONFIGURATION; NOTE; AUTO LEARN; green; place
DS2100N QUICK GUIDE 6 STEP 3 – X-PRESS™ CONFIGURATION X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance. Status and diagnostic information are clearly presented by means of the five colored LEDs, whereas the single push button gives immediate ...
Page 7 - If your application has been configured using X-PRESSTM, go to STEP 5.; RESET SCANNER TO FACTORY DEFAULT (OPTIONAL)
DS2100N QUICK GUIDE 7 3. Exit the process by pressing the X-PRESS™ push button once. The scanner will restart at the end of the process, and then the detected barcodes are automatically configured in scanner memory. NOTE If the barcode cannot be read because of low contrast or excessive ambient ligh...
Page 8 - STEP 4 – INSTALL GENIUSTM CONFIGURATION PROGRAM; Wizard approach for new users; WIZARD FOR QUICK READER SETUP; the
DS2100N QUICK GUIDE 8 STEP 4 – INSTALL GENIUS™ CONFIGURATION PROGRAM Genius ™ is a Datalogic scanner configuration tool providing several important advantages: • Wizard approach for new users; • Multi-language version; • Defined configuration directly stored in the reader; • Communication protocol i...
Page 11 - STEP 5 – TEST MODE; By default, the Test Mode exits automatically after two minutes.
DS2100N QUICK GUIDE 11 STEP 5 – TEST MODE Use a code suitable to your application to test the system. Alternatively, you can use the Datalogic Test Chart (Interleaved 2/5 or Code 39). 1. Enter the Test mode function by holding the X-PRESS™ push button pressed until the TEST LED is on. 2. Release the...
Page 12 - ADVANCED SCANNER CONFIGURATION; HOST MODE PROGRAMMING; ALTERNATIVE LAYOUTS
DS2100N QUICK GUIDE 12 ADVANCED SCANNER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Manual on the installation CD-ROM or downloadable from the web site through this link: www.automation.datalogic.com/ds2100n . The following are alternative or ...
Page 13 - APPENDIX; READING DIAGRAMS
DS2100N QUICK GUIDE 13 APPENDIX READING DIAGRAMS DS2100N-1200 (Standard Resolution) CONDITIONS Optic Version = Linear Code = Interleaved 2/5 Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Reading Conditions = Standard *Scan Speed = 500 scans/sec * Parameter selectable in Geniu...
Page 14 - High Performance (Standard Resolution)
DS2100N QUICK GUIDE 14 DS2100N-1204 High Performance (Standard Resolution) CONDITIONS Optic Version = Linear Code = Interleaved 2/5 Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Code Resolution: High - for 0.30 mm (12 mils) codes and smaller Standard - for 0.50 mm (20 mils) c...
Page 16 - MECHANICAL INSTALLATION; mm
DS2100N QUICK GUIDE 16 MECHANICAL INSTALLATION 23.3* 0.92 14 0.55 84 3.31 4 0.16 10.3 0.41 40 1.57 0.41 10.3 40 1.57 14.7 0.58 M 4 n° 4 1.29 32.7 mminch 68 2.68 46 1.81 SETUP LEARN TEST READY GOOD TRIGGER COM STATUS DS2100N X PRESS INTERFACE * The quote refers to the scan line Figure 10 – DS2100N Ov...
Page 17 - LASER SAFETY; POWER SUPPLY; which case the user may be required to take adequate measures.
DS2100N QUICK GUIDE 17 PATENTS This product is covered by one or more of the following patents: U.S. patent: 5,992,740 European patent: 789,315 B1 COMPLIANCE LASER SAFETY The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product accordin...
Page 18 - DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS2100N Laser Scanner; e tutti i suoi modelli and all its models et tous ses modèles und sein...