Product Reference Guide i- i Table of Contents About This Manual ............................................................................................................... 1-1 Manual Conventions .......................................................................................................
i-ii Magellan ® 1000i Wand Idle State ........................................................................................ 3-27 Signal Speed ............................................................................................ 3-28 Transmit Trailing Noise ....................................
Product Reference Guide 1-1 Chapter 1 Getting Started The Magellan ® 1000i Omni-Directional Imaging Scanner offers hands-free scanning for small, easily handled items and handheld scanning for bulkier items. Its aggressive imaging perfor-mance and intuitive operation reduces user training and speeds...
Getting Started 1-2 Magellan ® 1000i Connecting the Scanner The scanner kit you ordered to match your interface should provide a compatible cable for your installation. Use the appropriate instructions below to connect the scanner to the terminal, PC or other host device. Upon completing the connect...
Programming Product Reference Guide 1-3 Wand Emulation Connection — Connect the scanner to the appropriated port on the ter- minal/PC using the correct cable for the interface type you ordered. Reference Figure 2 . IBM Connection — Connect the scanner to the IBM port on the terminal/PC using the cor...
Getting Started 1-4 Magellan ® 1000i LED and Beeper Indicators The scanner’s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner. The tables below list these indications. One exception to the behaviors listed in the tables is that the scanner’s function...
Error Codes Product Reference Guide 1-5 Error Codes Upon startup, if the scanner flashes its indicator LED or sounds an unexpected series of beep tones (other than normal power-up indications), this means the scanner has not passed its auto-matic Selftest and has entered FRU 1 isolation mode. If the...
Product Reference Guide 2-1 Chapter 2 General Features Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession). START / END PROGRAMMING BARCODES 0.1 Second 0.2 Second 0....
General Features 2-2 Magellan ® 1000i Double Read Timeout — cont. START / END PROGRAMMING BARCODES 0.7 Second 0.8 Second 0.9 Second 1 Second
Label Gone Timeout Product Reference Guide 2-3 Label Gone Timeout This feature sets the time after the last label segment is seen before the scanner prepares for a new label. Productivity Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented...
General Features 2-4 Magellan ® 1000i Sleep Mode This feature specifies the amount of time with no barcode reads before the scanner enters sleep mode. START / END PROGRAMMING BARCODES 15 Seconds 30 Seconds 1 Minute 2 Minutes 3 Minutes 4 Minutes 5 Minutes
General Features 2-6 Magellan ® 1000i LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation. START / END PROGRAMMING BARCODES Disable Enable DEFAULT
LED and Beeper Indicators Product Reference Guide 2-7 Good Read: When to Indicate This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after trans...
General Features 2-8 Magellan ® 1000i Good Read Beep Control This feature enables/disables the scanner’s ability to beep upon a successful decode of a barcode. Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. ...
LED and Beeper Indicators Product Reference Guide 2-9 Good Read Beep Length Specifies the duration of a good read beep. START / END PROGRAMMING BARCODES 60msec 80msec DEFAULT 100msec 120msec 140msec 160msec 180msec 200msec
General Features 2-10 Magellan ® 1000i Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. START / END PROGRAMMING BARCODES Low Medium High DEFAULT
Scanning Features Product Reference Guide 2-11 Scanning Features Targeted Scanning Mode Upon pressing the button, the scanner will project an aiming pattern to assist in centering over the barcode. Scanning then takes place as soon as the button is released. Configuration options for Targeted Scanni...
General Features 2-12 Magellan ® 1000i Target Mode Linger Time Specifies the time duration the scanner remains in the targeted mode of operation after reading a barcode before reverting to Omni-directional Mode. START / END PROGRAMMING BARCODES Short Duration Medium Duration DEFAULT Long Duration
Scanning Features Product Reference Guide 2-13 Wake Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode. Lower settings provide greater sensitivity. The seelectable range for this setting is 5% to 15%. START / END PROGR...
General Features 2-14 Magellan ® 1000i Wake Up Intensity — cont. START / END PROGRAMMING BARCODES 13% 14% 15%
Product Reference Guide 3-1 Chapter 3 Interface Related Features At the time of this writing, the Scanner supports the interfaces listed in Table 3-1 . Select the desired interface type from the table, then reference the page number given for the customizable features section associated with each in...
Interface Selection Product Reference Guide 3-3 Interface Selection START / END PROGRAMMING BARCODES RS-232 Standard RS-232 Wincor-Nixdorf IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 USB-OEM USB Keyboard Wand Emulation USB COM
Interface Related Features 3-4 Magellan ® 1000i Interface Selection — cont. START / END PROGRAMMING BARCODES Keyboard Wedge A Keyboard Wedge B Keyboard Wedge C Keyboard Wedge D Keyboard Wedge E Keyboard Wedge F Keyboard Wedge G \ Keyboard Wedge H Keyboard Wedge I Keyboard Wedge J ³ 0 0 0 1 3 2
Interface Features Product Reference Guide 3-7 Interface Features Obey/Ignore Host Commands When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface, select ...
Interface Related Features 3-8 Magellan ® 1000i Interface Features — cont. Host Transmission Buffers Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar-code, the scanner can continue to read a new barcode while the old one is being transmitted to the host...
Interface Features Product Reference Guide 3-9 RS-232 Interface Features START / END PROGRAMMING BARCODES 1200 Baud 2400 Baud 4800 Baud 9600 Baud DEFAULT 19200 Baud 38400 Baud 57600 Baud 115200 Baud ³
Interface Features Product Reference Guide 3-11 RS-232 Interface Features — cont. Hardware Flow Control Disable Hardware Control— The scanner transmits to the host regardless of any activity on the CTS line. Enable CTS Flow Control— The CTS signal controls transmission of data to the host. Enable CT...
Interface Related Features 3-12 Magellan ® 1000i RS-232 Interface Features — cont. Intercharacter Delay This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make ...
Interface Features Product Reference Guide 3-13 Intercharacter Delay — cont. Software Flow Control Disables/Enables software control using XON/XOFF characters. START / END PROGRAMMING BARCODES Interchar Delay = 80 msec Interchar Delay = 90 msec START / END PROGRAMMING BARCODES Disable Software Flow ...
Interface Related Features 3-14 Magellan ® 1000i RS-232 Interface Features — cont. Host Echo When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary. If,...
Interface Features Product Reference Guide 3-15 RS-232 Interface Features — cont. Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the barcode data that has just been scann...
Interface Related Features 3-16 Magellan ® 1000i Host Echo Quiet Interval — cont. Signal Voltage: Normal/TTL Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS. START / END PROGRAMMING BARCODES Host Echo Quiet Interval = 80msec Host Echo Quiet Interval = 90msec...
Interface Features Product Reference Guide 3-17 RS-232 Invert Enables/disables inversion of RS-232 TXD and RXD signals. Beep on ASCII BEL Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex). START / END PROGRAMMING BARCODES Disable RS-232 Invert DE...
Interface Related Features 3-18 Magellan ® 1000i Beep on Not on File Select for the host to beep (or not) when a not-on-file (host command) condition is detected by the host. START / END PROGRAMMING BARCODES Disable Beep on Not On File Enable Beep on Not On File DEFAULT
Interface Features Product Reference Guide 3-19 ACK NAK Options This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for t...
Interface Related Features 3-20 Magellan ® 1000i RS-232 Interface Features — cont. — cont. ACK Character NAK Character START / END PROGRAMMING BARCODES Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as i...
Interface Features Product Reference Guide 3-21 RS-232 Interface Features — cont. Retry on ACK NAK Timeout Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following fea-ture) has expired. ACK NAK Timeout Value START / END PROGRAMMING BARCODES Disable Retry on ACK NAK ...
Interface Related Features 3-22 Magellan ® 1000i RS-232 Interface Features — cont. ACK NAK Retry Count START / END PROGRAMMING BARCODES This feature sets the number of times for the scanner to retry a label transmission under a retry condition.000 = No retry001 - 254 = Retry for the specified number...
Interface Features Product Reference Guide 3-23 RS-232 Interface Features — cont. ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and com-municatio...
Interface Related Features 3-24 Magellan ® 1000i RS-232 Interface Features — cont. Transmission Failure Indication Enables/disables bad-label indication upon transmission failure. USB-OEM Interface Features USB-OEM Device usage The USB-OEM protocol allows for the scanner to be identified as one of t...
Interface Features Product Reference Guide 3-25 IBM IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 ...
Interface Related Features 3-26 Magellan ® 1000i Wand Emulation Supported Symbologies The Wand Emulation interface will transmit barcode data as a wand device would. This inter-face will transmit the following barcode symbologies: • UPC/EAN • UPC/EAN with addons • Code 39 • Full ASCII Code 39 • Inte...
Interface Features Product Reference Guide 3-27 Wand Emulation — cont. Bar/Space Polarity Low/High — Black will be transmitted as a low voltage level (0 to +0.7V) and space as high level (+2.4 to +5.25V). High/Low — Black will be transmitted as a high voltage level (+2.4 to +5.25V) and space as low ...
Interface Related Features 3-28 Magellan ® 1000i Wand Emulation — cont. Signal Speed The speed of the transmission can be set. This selects the width of the minimum narrow bar. 330 microseconds 660 microseconds Transmit Trailing Noise The transmission of noise pulses after the label may be enabled o...
Interface Features Product Reference Guide 3-29 Wand Emulation — cont. Transmit Leading Noise The transmission of noise pulses before the barcode may be enabled or disabled. Symbology Conversion Wand Emulation can convert all barcodes to a single symbology. Choices are: No Conversion Convert to Code...
Interface Related Features 3-30 Magellan ® 1000i Keyboard Wedge and USB Keyboard As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The instal-lation of the wedge is a fairly simple process that doesn’t require any changes of software or hard-ware. Keyboard Layout The ...
Interface Features Product Reference Guide 3-31 Keyboard Wedge — cont. START / END PROGRAMMING BARCODES Italy Norway Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech
Interface Related Features 3-32 Magellan ® 1000i Keyboard Wedge — cont. Caps Lock State Specifies the format in which the scanner sends character data. START / END PROGRAMMING BARCODES Slovakia Romania Croatia Poland ³ START / END PROGRAMMING BARCODES Disable Caps Lock DEFAULT Caps Lock “ON” Shift L...
Interface Related Features 3-36 Magellan ® 1000i Keyboard Wedge — cont. Intercharacter Delay USB COM Interface Set-up This interface uses the Microsoft Windows USB COM driver. Before plugging your reader into the host PC, please ensure you have already copied the DLS_EUG_CDC_ACM.inf file pro-vided b...
Product Reference Guide 4-1 Chapter 4 Data Editing Data Editing Overview When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “message string.” The features in ...
Data Editing 4-2 Magellan ® 1000i Global Prefix/Suffix Up to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/or as a suffix (in a position following the barcode data) as indicated in Figure 4-2 . Figure 4-2. Prefix and Suffix Positions Example: Setting a Pref...
Data Editing 4-4 Magellan ® 1000i AIM ID AIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list — as opposed to custom label ID characters you select yourself — and can be included with scanned barcode data. AIM label identifiers consist of thre...
Data Editing 4-12 Magellan ® 1000i Case Conversion This feature can convert scanned barcode data to either all lower case (a through z) or all upper case (A through Z) characters. NOTE Case conversion affects ONLY scanned barcode data,and does not affect Label ID, Prefix, Suffix, or otherappended da...
Character Conversion Product Reference Guide 4-13 Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second characte...
Product Reference Guide 5-1 Chapter 5 Symbologies The scanner supports the following symbologies (barcode types). Options for each symbology are included in this chapter. Factory Defaults— for the standard RS-232 interface are indicated in bold text throughout this section. Reference Appendix D, Def...
Symbologies 5-2 Magellan ® 1000i UPC-A — continued Check Digit Transmission Enable this option to transmit the check digit along with UPC-A barcode data. Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the sym-bology ID to match those required...
UPC-A Product Reference Guide 5-3 UPC-A — continued Number System Transmission This feature enables/disables transmission of UPC-A System Number. UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read. START...
UPC-E Product Reference Guide 5-5 UPC-E The following options apply to the UPC-E symbology. Disable/Enable UPC-E When disabled, the scanner will not read UPC-E barcodes. Check Digit Transmission Enable this option to transmit the check digit along with UPC-E barcode data. START / END PROGRAMMING BAR...
Symbologies 5-6 Magellan ® 1000i UPC-E — continued Number System Digit The Number System Digit (NSD) which is always a zero (0) in the leading position can be optionally included (or not) with scanned barcode data. Expand to UPC-E to UPC-A Enables/disables expansion of UPC-E labels to UPC-A. Selecti...
UPC-E Product Reference Guide 5-7 UPC-E — continued Expand UPC-E to EAN13 Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also changes the symbology ID to match those required for EAN-13. Minimum Reads This feature specifies the minimum number of consecutive times a UPC-...
Symbologies 5-8 Magellan ® 1000i GTIN The following options apply to the GTIN label data format. Expand UPC/EAN to GTIN When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format. START / END PROGRAMMING BARCODES Don’t Expand to GTIN DEFAULT Expand to GTIN
EAN-13 Product Reference Guide 5-9 EAN-13 The following options apply to the EAN-13 symbology. Disable/Enable EAN-13 When disabled, the scanner will not read EAN-13 barcodes. Check Digit Transmission Enable this option to transmit the check digit along with EAN-13 barcode data. START / END PROGRAMMI...
Symbologies 5-10 Magellan ® 1000i EAN-13 — continued EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. ISBN When enabled, this feature truncates the leading three digits from labels that contain ISBN (International Standard Book Number) and appends an ISBN check ...
EAN-13 Product Reference Guide 5-11 EAN-13 — continued Minimum Reads This feature specifies the minimum number of consecutive times an EAN-13 label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT Minimum = 2 Reads Minimum = 3 Reads Minimu...
Symbologies 5-12 Magellan ® 1000i EAN-8 The following options apply to the EAN-8 symbology. Disable/Enable EAN-8 When disabled, the scanner will not read EAN-8 barcodes. Check Digit Transmission Enable this option to transmit the check Digit along with EAN-8 barcode data. START / END PROGRAMMING BAR...
Add-ons Product Reference Guide 5-15 Add-ons Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN barcodes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported opti...
GS1 DataBar Omnidirectional / Stacked Omnidirectional Product Reference Guide 5-17 GS1 DataBar Omnidirectional / Stacked Omnidirectional The following options apply to the GS1 DataBar Omnidirectional symbology. Disable/Enable GS1 DataBar Omnidirectional When this feature is disabled, the scanner wil...
Symbologies 5-18 Magellan ® 1000i GS1 DataBar Omnidirectional / Stacked Omnidirectional — continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Omnidirec-tional label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES ...
GS1 DataBar Expanded / Expanded Stacked Product Reference Guide 5-19 GS1 DataBar Expanded / Expanded Stacked The following options apply to the GS1 DataBar Expanded symbology. Disable/Enable GS1 DataBar Expanded When this feature is disabled, the scanner will not read GS1 DataBar Expanded barcodes. ...
Symbologies 5-20 Magellan ® 1000i GS1 DataBar Expanded / Expanded Stacked — continued Length Control Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding— When varia...
GS1 DataBar Expanded / Expanded Stacked Product Reference Guide 5-21 GS1 DataBar Expanded / Expanded Stacked — continued GS1 DataBar Expanded Length 1, Length 2 Programming Instructions 1. Scan the START/END barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alp...
GS1 DataBar Expanded / Expanded Stacked Product Reference Guide 5-23 GS1 DataBar Expanded / Expanded Stacked — continued Coupon Read Control This feature controls coupon reading. START / END PROGRAMMING BARCODES Disable coupon filtering Enable UPCA coupon decoding Disable GS1 DataBar coupon decoding...
Symbologies 5-24 Magellan ® 1000i GS1 DataBar Limited The following options apply to the GS1 DataBar Limited symbology. Disable/Enable GS1 DataBar Limited When this feature is disabled, the scanner will not read GS1 DataBar Limited barcodes. GS1-128 Emulation When enabled, GS1 DataBar Limited barcod...
GS1 DataBar Limited Product Reference Guide 5-25 GS1 DataBar Limited — continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label must be decoded before it is accepted as good read. START / END PROGRAMMING BARCODES Minimum = 1 Read DEFAULT Min...
Symbologies 5-26 Magellan ® 1000i Code 39 The following options apply to the Code 39 symbology. Disable/Enable Code 39 When this feature is disabled, the scanner will not read Code 39 barcodes. Check Character Calculation When enabled, the scanner will calculate the check character of the labels. Tu...
Code 39 Product Reference Guide 5-27 Check Character Transmit Enable this option to transmit the check character with scanned barcode data. Start/Stop Characters Enables/disables transmission of Code39 start and stop characters. START / END PROGRAMMING BARCODES Disable Check Char Transmission Enable...
Symbologies 5-28 Magellan ® 1000i Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters . START / END PROGRAMMING BARCODES Disable Code 39 Full ASCII DEFAULT Enable Code 39 Full ASCII
Code 39 Product Reference Guide 5-29 Code 39 — continued Length Control Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding— When variable length decoding is enable...
Symbologies 5-30 Magellan ® 1000i Code 39 Length 1, Length 2 Programming Instructions 1. Scan the START/END barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the length in decimal notation...
Code 39 Product Reference Guide 5-31 Code 39 — continued Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 barcode are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s soft-ware, and the data will be decod...
Symbologies 5-32 Magellan ® 1000i Pharmacode 39 The following options apply to the Pharmacode 39 symbology. Disable/Enable Pharmacode 39 When this feature is disabled, the scanner will not read Pharmacode 39 barcodes. Start/Stop Characters Enables or disables transmission of Pharmacode 39 start/stop...
Symbologies 5-34 Magellan ® 1000i Code 128 The following options apply to the Code 128 symbology. Disable/Enable Code 128 When this feature is disabled, the scanner will not read Code 128 barcodes. Disable/Enable EAN 128 When this feature is disabled, the scanner will not read EAN 128 barcodes. STAR...
Code 128 Product Reference Guide 5-37 Code 128 — continued Code 128 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the leng...
Interleaved 2 of 5 Product Reference Guide 5-39 Interleaved 2 of 5 The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology. Disable/Enable Interleaved 2 of 5 When this feature is disabled, the scanner will not read Interleaved 2 of 5 barcodes. Check Digit Calculation When enabled,...
Symbologies 5-40 Magellan ® 1000i Interleaved 2 of 5 — continued Check Digit Transmit Enable this option to transmit the check digit with scanned barcode data. START / END PROGRAMMING BARCODES Disable Check Digit Calculation DEFAULT Enable Check Digit Calculation
Symbologies 5-42 Magellan ® 1000i Interleaved 2 of 5 — continued Interleaved 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represe...
Interleaved 2 of 5 Product Reference Guide 5-43 Interleaved 2 of 5 — continued Interleaved 2 of 5 Stitching Enables/disables stitching for Interleaved 2 of 5 labels. When parts of an Interleaved 2 of 5 bar-code are presented to the scanner with this feature enabled, the barcode parts will be assembl...
Codabar Product Reference Guide 5-45 Codabar The following options apply to the Codabar symbology. Disable/Enable Codabar When this feature is disabled, the scanner will not read Codabar barcodes. Check Character Verification When enabled, the scanner will verify the check character of the labels. S...
Codabar Product Reference Guide 5-47 Codabar — continued Length Control Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding— When variable length decoding is enable...
Symbologies 5-48 Magellan ® 1000i Codabar — continued Codabar Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the length in ...
Codabar Product Reference Guide 5-49 Codabar — continued Start/Stop Character Type Codabar has four pairs of Start/Stop patterns. Select one pair to match your application. Start/Stop Character Transmission The transmission of start and end characters of Codabar is selected below. START / END PROGRA...
Symbologies 5-50 Magellan ® 1000i Start/Stop Character Match This feature enables/disables the requirement that start and stop characters match . Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to the scanner with this feature enabled, the...
Symbologies 5-52 Magellan ® 1000i Code 93 The following options apply to the Code 93 symbology. Disable/Enable Code 93 When this feature is disabled, the scanner will not read Code 93 barcodes. START / END PROGRAMMING BARCODES Disable Code 93 DEFAULT Enable Code 93
Code 93 Product Reference Guide 5-53 Code 93 — continued Length Control Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding— When variable length decoding is enable...
Symbologies 5-54 Magellan ® 1000i Code 93 — continued Code 93 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the length in ...
Code 93 Product Reference Guide 5-55 Code 93 — continued Code 93 Stitching Enables/disables stitching for Code 93 barcodes. When parts of a Code 93 label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s soft-ware, and the data will be decod...
Symbologies 5-56 Magellan ® 1000i MSI/Plessey The following options apply to the MSI/Plessey symbology. Disable/Enable MSI/Plessey When this feature is disabled, the scanner will not read MSI/Plessey barcodes. Check Digit Verification This feature specifies whether one or two check digits are to be ...
MSI/Plessey Product Reference Guide 5-57 MSI/Plessey — continued Check Digit Transmit When this option is enabled, the scanner will transmit one-digit or two-digit check digits, depending upon the setting for check digit verification. Number of Check Characters Specifies number of MSI/Plessey check ...
MSI/Plessey Product Reference Guide 5-59 MSI/Plessey — continued MSI/Plessey Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing...
Symbologies 5-60 Magellan ® 1000i MSI/Plessey — continued MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey barcodes. When parts of an MSI/Plessey label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software, and the data ...
Symbologies 5-62 Magellan ® 1000i Standard 2 of 5 The following options apply to the Standard 2 of 5 symbology. Disable/Enable Standard 2 of 5 When this feature is disabled, the scanner will not read Standard 2 of 5 barcodes. Check Digit Verification When enabled, the scanner will verify the check d...
Standard 2 of 5 Product Reference Guide 5-63 Standard 2 of 5 — continued Check Digit Transmit When this option is enabled, the scanner will transmit the check digit. START / END PROGRAMMING BARCODES Disable Check Digit Transmission Enable Check Digit Transmission DEFAULT
Standard 2 of 5 Product Reference Guide 5-65 Standard 2 of 5 — continued Standard 2 of 5 Length 1, Length 2 Programming Instructions 1. Scan the START barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) re...
Symbologies 5-66 Magellan ® 1000i Standard 2 of 5 — continued Standard 2 of 5 Stitching Enables/disables stitching for Standard 2 of 5 barcodes. When parts of a Standard 2 of 5 label are presented to the scanner with this feature enabled, the barcode parts will be assembled by the scanner’s software...
Product Reference Guide 6-1 2D Symbologies & Advanced Decoding Features NOTE The features in this section are available ONLY for models with 2D featuresactivated.
2D Symbologies & Advanced Decoding Features 6-2 Magellan ® 1000i 2D Symbologies The scanner supports the following 2D symbologies (barcode types): PDF 417 and Datamatrix . Options for each symbology are included in this addendum. Factory Defaults— for the std. RS-232 interface are indicated in b...
2D Symbologies & Advanced Decoding Features 6-6 Magellan ® 1000i Datamatrix Disable/Enable Datamatrix When disabled, the scanner will not read Datamatrix barcodes. START / END PROGRAMMING BARCODES Disable Datamatrix Enable Datamatrix
2D Symbologies Product Reference Guide 6-7 Datamatrix — continued Length Control Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding— When variable length decoding ...
2D Symbologies & Advanced Decoding Features 6-10 Magellan ® 1000i Image Capture How to Capture an Image To initiate an Image Capture, scan the IMAGE CAPTURE label below, and press the button. A targeting “pointer” will be illuminated while the button is pressed. Upon release of the button, the i...
Product Reference Guide A-1 Chapter A Product Specifications Optical and Read Performance Parameters Scanner Dimensions Parameter Specification Scan Volume 70 cubic inches Scan Pattern 100 lines Scan Rate 1,100 digital scan lines Minimum Resolution 5 mil Depth of Field(100% UPC Labels) 0 - 6” Minimu...
A-2 Magellan ® 1000i Physical Properties Electrical Parameters Environmental Parameters Other Parameters Parameter Specification Dimensions (Scanner only): 3.3” x2.8” x3.7” Dimensions (Scanner w/Base Station): 5.5” x2.9” x3.8” Weight (Scanner) 7.0 oz. Weight (Base Station) 6.6 oz. Parameter Specific...
Product Reference Guide B-1 Chapter B Cable Pinouts Standard Cable Pinouts (Primary Interface Cables) RS-232 IBM Port 5B/9B/17 12 CTS34 RTS5 RXD6 TXD78 VCC IN9 GND10 1234 DATA -56 DATA +78 VCC_IN9 GND10 Pin 1 10 Position RJ (Scanner End) Pin 1 10 Position RJ (Scanner End)
Product Reference Guide C-1 Chapter C Alpha-Numeric Pad A B C D E F
Product Reference Guide D-1 Appendix D Default Settings Defaults by Symbology The following is a partial list of key settings for each symbology type. Code Type Read Enable Checksum Verification Enable Checksum Transmission Enable Label ID UPC-A ✓ ✓ ✓ A UPC-E ✓ ✓ ✓ E EAN-13 ✓ ✓ ✓ F EAN-8 ✓ ✓ ✓ FF GS...
D-2 Magellan ® 1000i Interface Default Exceptions The factory default settings indicated in the programming sections (in bold text) reflect factory configuration for the RS-232 standard interface. The following tables list default exceptions by interface for the remaining available interfaces. IBM I...
Interface Default Exceptions Product Reference Guide D-3 Interface Default Exceptions — continued RS-232 Wincor/Nixdorf Parameter Default Setting Interface Type RS-232-WN Number of Host Transmit Buffers One Buffer RS-232 Parity Odd RS-232 Hardware Control CTS Flow Control UPC-E Check Character Conve...
D-4 Magellan ® 1000i Interface Default Exceptions — continued Wand Emulation Keyboards Keyboard interfaces include USB Keyboard and Keyboard Wedge A-Y. Parameter Default Setting Interface Type Wand Emulation Code 39 Start/Stop Character Transmission Enable Parameter Default Setting Keyboard Wedge In...
Product Reference Guide E-1 Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Table E-1 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of th...
Product Reference Guide F-1 Chapter F Host Commands Accepting RS-232 Commands The scanner responds to the following RS-232 commands: If one of the above commands is received, the scanner will perform the steps indicated for the command. Host commands for other interfaces are also available. Contact ...
Product Reference Guide G-1 Chapter G Sample Symbols 0 1234567890 1234567890 Code 128 9 780330 290951 BC321 123456-9$ 123456 UPC-A Code 128 Code 39 Code 93 Interleaved 2 of 5 EAN-13 Code 2 of 5 A13579B Codabar 0 5
G-2 Magellan ® 1000i Sample Symbols (01)00123456789012 GS1 DataBar Omni- 0100123456789050 GS1 DataBar Expanded
Datalogic Manuals
-
Datalogic CBX100
Manual
-
Datalogic F725-E/RF
Manual
-
Datalogic XLR
Manual
-
Datalogic QS2500
Manual
-
Datalogic DS4800
Manual
-
Datalogic DS1100 SH2347
Manual
-
Datalogic Matrix-2000
Manual
-
Datalogic DS2200
Manual
-
Datalogic SR
Manual
-
Datalogic I GD4100
Manual
-
Datalogic Universal Keyboard Wedge Connectivity