Page 2 - TABLE OF CONTENTS; Monitoring...................................................................; Appendix 1. IP Address Settings of CyberPower Network
TABLE OF CONTENTS INTRODUCTION…………………………………...………………… 1 INSTALLATION GUIDE…………………………………...………… 4 CONFIGURATION GUIDE…………………...………………...…… 7 Monitoring…………………………………………………………. 7 Current Status..………………………………………………… 7 UPS Information...………………..……………………………. 8 Control….…………………………………………………………. 9 UPS Contro...
Page 3 - INTRODUCTION; Features
Cyber Power Network Management System 1 INTRODUCTION Overview The CyberPower Network Management Card is an external card that allows remote monitoring and control of a UPS on a network. After installing the hardware and configuring an IP address, the user can access, monitor and control the UPS from...
Page 4 - Unpacking; CyberPower Network Management Card
Cyber Power Network Management System 2 Unpacking Inspect the Network Management Card upon receipt. The package should contain the following: z CyberPower Network Management Card z PowerPanel ® Shutdown Service Software and user manuals CD z AC adapter ( For select UPS models only )
Page 5 - Description; indicates the status of connection between UPS and the Network
Cyber Power Network Management System 3 z Description 1) Serial Port provides a connection for communication between the UPS and the Network Management Card 2) Reset Button is used to reset the settings. When the Reset Button is pushed for 3 seconds, all settings except for the IP address for Networ...
Page 6 - INSTALLATION GUIDE; Step 1. Hardware Installation; is optional to use the serial cable included.; Method 1 : Use SNMP Card Configuration Tool Setting; Install the SNMP Card Configuration Tool from the included CD
Cyber Power Network Management System 4 INSTALLATION GUIDE Step 1. Hardware Installation 1. Connect the Ethernet cable to the LAN port of the CyberPower Network Management Card. 2. Connect the CyberPower Network Management Card to the UPS communication port. It is optional to use the serial cable in...
Page 7 - new addresses into the corresponding fields.
Cyber Power Network Management System 5 Figure 2. The SNMP card setting window. 6. First, choose either IP or MAC address from the device address option. 7. Then click on each checkbox to modify the IP, subnet mask or gateway address. Enter the new addresses into the corresponding fields. 8. You wil...
Page 8 - Method 2 : Use DOS Mode Setting; has the MAC address; Ente; and press; Enter; Configuration to establish the IP address.
Cyber Power Network Management System 6 Figure 4. Setup IP Address successfully message. Method 2 : Use DOS Mode Setting 1. Obtain the MAC address indicated on the label of the Network Management Card rear panel. (Each Management Card has a unique MAC address). 2. Use the ARP commend to set you IP a...
Page 9 - CONFIGURATION GUIDE
Cyber Power Network Management System 7 CONFIGURATION GUIDE [Monitoring] menu contains [Current Status] page and [UPS Information] page [Current Status] displays basic information of UPS current status. Status Field Definition Input Line Voltage Shows the current input voltage of the utility power O...
Page 14 - Retype the password to confirm the password was keyed properly.
Cyber Power Network Management System 12 [System] menu contains, [System Time] page [User Accounts] page and [Identification] page. [System Time] allows users to configure the internal time of the Network Management Card 。 1. Enter the date and time and choose either Celsius or Fahrenheit for the te...
Page 15 - assign the system’s name, contact, and location of the system.
Cyber Power Network Management System 13 [Identification] assign the system’s name, contact, and location of the system. [Network] menu contains [TCP/IP] page, [Access Control] page and [Trap Notification] page. [TCP/IP] This option allows you to enable or disable DHCP and define the IP Address, Sub...
Page 17 - Red
Cyber Power Network Management System 15 1. Input the receivers IP address. This address will identify the receiver of traps. The default value 0.0.0.0 or 255.255.255.255 defines all NMS as receivers. 2. Input the community (functioned as password, maximum of 15 characters). 3. Select one option [En...
Page 18 - Information; indicates an event that requires no action.; Warning; indicates an event that requires immediate attention.
Cyber Power Network Management System 16 Information indicates an event that requires no action. Warning indicates an event that does not require immediate attention, but this condition should be monitored. Severe indicates an event that requires immediate attention. 1. Determine the severity levels...
Page 20 - Overview; The computer will display network information as below:; Select an IP Address for CyberPower Network Management Card
Cyber Power Network Management System 18 Appendix 1 IP Address Settings of CyberPower Network Management Card Overview All devices on a computer network need to have an IP address. Each device’s IP address is unique. The same address cannot be used twice. In order to assign an IP address to the Cybe...