Page 2 - Physical Description
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Physical Description This section shows the dimensions of the CRESTRON GREEN LIGHT EXPRESS power switching cabinets. Dimensions of GLPX-HSW-FT-8 , -12, -16 Power Switching Cabinets (Front, Side and Bottom View) 24 1/4" (616 mm) 1...
Page 5 - Installed GLXP modules come with additional tie wrap holders.
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Dimensions of GLPX-HSW-FT-20, -24, -28, -32 Power Switching Cabinets (Internal View) 2 1/8” (55 mm) (2X) Ø 5/16”(Ø 8 mm) MOUNTING HOLES (2x) 11/16” (19 mm) 10 7/8” (276 mm) 2 1/4” (58 mm) GROUND LUG 38 7/8” (998 mm) 34 3/8” (873 mm) ...
Page 6 - Installation; Observe the following when installing the cabinet:; Clearance
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Installation Observe the following when installing the cabinet: • The cabinet must be mounted by a licensed electrician in accordance with all national and local codes. Refer to the diagram below for specific requirements. • The cabi...
Page 7 - Wiring; SW
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Wiring NOTE: All wiring must be installed in accordance with all local and national electrical codes. NOTE: Refer to the torque settings specified on pages 8 and 9. CRE GLXP low profile switching modules installed. The follo e cabine...
Page 8 - CAUT; AND; NEUTRAL
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Feed-Through and Load Wiring (Section A) ION: Bypass jumpers are provided on each output to allow testing and to protect the modules during CAUT installation. The jumper shorts the L and SW terminals so that the load circuit is energ...
Page 9 - Interface connectors for; TERMINAL CONNECTOR; NET
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Control Wiring (Section B) The bottom of the cabinet contains Cresnet connections for interfacing to the rest of the Crestron control systemand a power port to provide an alternate source of 24 volt power to the modules. It also prov...
Page 10 - PO; OVERRIDE Port Wiring
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT ® EXPRESS NET Port Wiring When wiring the supplied NET connectors for connection to a Crestron control system or other device on the Cresnet network, use Crestron certified wire such as CRESNET-NP or CRESNET-P. To ensure optimum performance ov...
Page 11 - Testing; Ma; Ov; Save Override Settings; System Operation and Commissioning
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Testing Ma Ligh To tand trele NO ram may change the settings if the Override mode is not enabled . nual Control ting modules can be manually controlled from the front panel. oggle the output between off and on, tap the appropriate ON...
Page 12 - Problem Solving; ituations. If further assistance is required, please; Override; Further Inquiries; user account
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Problem Solving Troubleshooting ituations. If further assistance is required, please TROUBLE The following table provides corrective action for possible trouble scontact a Crestron customer service representative. Troubleshooting POS...
Page 13 - Appendix A: Setting Module Net IDs; Setup
CRESTRON GREEN LIGHT ® EXPRESS Power Switching Cabinet GLPX-HSW-FT Appendix A: Setting Module Net IDs The following procedure will normally be performed by an authorized Crestron representative as part of the System system wiring and basic testing as described on pages 7 and 11, it is not necessary ...
Page 14 - Appendix B: Specifications; SPECIFICATION DETAILS
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Appendix B: Specifications Specifications for the GLXP modules are listed in the following table. GLXP Module Specifications SPECIFICATION DETAILS Input Voltage 100 – 277 VAC 50/60 Hz Supported Load Types Incandescent, HID, magnetic ...
Page 16 - Return and Warranty Policies; Merchandise Returns / Repair Service; ing mechanical parts, pan/tilt heads and; ns: disk drives and any other moving or rotat
Power Switching Cabinet GLPX-HSW-FT CRESTRON GREEN LIGHT ® EXPRESS Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact ...