Page 4 - SAFETY INSTRUCTIONS - CONTINUED
7) Installation and repair should be done by a qualified service person. The heater should be inspected before useand at least annually by a professional service person. More frequent cleaning may be required due to excessivelint from carpeting, bedding, material, etc. It is imperative that control ...
Page 5 - INSTALLATION; FIGURE 9
STEP 4. Compare the total Btu the area can support (from Step 2) to the total Btu in the area the heater will be installed(from Step 3). If the total from Step 2 is larger this is considered an unconfined space, if Btu total from Step 3 is larger thisis considered a confined space and provisions mus...
Page 6 - INSTALLATION - CONTINUED; FIGURE 2; CLEARANCES; GAS INLET LOCATION
3) Protect heater from wind, high traffic areas, and drafts (such as doorways, locations that get direct air from a ceilingfan, etc.) as this will cause nuisance pilot outage. 4) All models may be wall mounted using the factory supplied (standard) wall mounting bracket. Additionally allmodels may be...
Page 7 - NA
Nominal Iron Pipe Internal Size, Diameter , Inches Inches 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 1 2 5 150 1 7 5 2 0 0 ¼ 0.364 43 29 24 20 18 16 15 14 13 12 11 10 9 8 3 /8 0.493 95 65 52 45 40 36 33 31 29 27 24 22 20 19 ½ 0.622 17 5 12 0 97 82 73 66 61 57 53 50 44 40 37 35 ¾ 0.824 360 250 200 170...
Page 8 - PROPANE GAS
TABLE 1 – first stage pipe sizing 10 PSIG Inlet with a 1 PSIG Pressure DropMaximum capacity of pipe or tubing, in thousands of BTU/hr. of L.P. Gas Size of Pipe LENGTH OF PIPE OR TUBING, FEET* Or CopperTubing, Inches 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 3 / 8 5 5 8 3 8 3 3 0 9 2 6 5 2 3 5 2 1 3 ...
Page 9 - FIGURE 3; INSTALLING VF-FSK FLOOR BASE KIT
INSTALLING HEATER WALL MOUNT (BFT10) STEP 1. Remove wall mounting bracket from back ofheater.STEP 2. Locate wall stud.STEP 3. Attach wall mounting bracket to wall studwith top at desired height, using (2) screws provided.Make sure top of bracket is level. See Figure 3.STEP 4. Hang top of heater on w...
Page 10 - GAS CONNECTION; FIGURE 6; FIGURE 6A; BURNER ORIFICE
GAS CONNECTION STEP 1. Make the gas connection between the manual shut off valve and regulator located insideheater cabinet. Hold regulator when tightening connection to prevent damage to regulatorand internal tubing. See Figure 6 for completed installation. NOTE: All piping and connection must be c...
Page 12 - PROPER OPERATION; CORRECT; LOW PRESSURE; CORRECT FLAME
PROPER OPERATION ODS / PILOT FLAME The pilot pressure has been pre-set at the factory and with proper supply pressure will provide a safe, reliable ignition source. See Figure 7. CORRECT INCORRECT - LOW PRESSURE INCORRECT - OXYGEN LEVEL DROPPING BURNER FLAME All orificing and pressure setting was do...
Page 13 - Apply Air; STEP 3 - PILOT CLEANING; MAINTENANCE; Burner may be cleaned by using a low pressure air hose, or soft brush.
Apply Air STEP 3 - PILOT CLEANING MAINTENANCE The entire heater should be checked and cleaned by a qualified service person before the start of eachheating season. More frequent cleaning may be required due to excessive lint conditions from carpeting,bedding material, etc. CABINET To clean the cabin...
Page 14 - BLOWER INSTRUCTIONS; WIRING DIAGRAM / VFB BLOWER
BLOWER INSTRUCTIONS INSTALLING THE VFB BLOWER (BFT201 / BFT202, BFT301 / BFT302 MODELS ONLY) STEP 1. Remove blower assembly from shipping carton.STEP 2. Insert blower assembly into upper back of heater (See Figure 11).STEP 3. Secure blower to heater using three #8 screws (provided) through holes pre...
Page 17 - MODEL NUMBERS NAT BFT101 BFT201 BFT301
REPLACEMENT PARTS LIST. TO ORDER REPLACEMENT PARTS YOU MUST GIVE MODEL NUMBER, SERIALNUMBER, TYPE OF GAS USED, PART DESCRIPTION AND PART NUMBER. MARCH 2005 Page 17 Mr. Contractor, we only sell parts through our wholesalers,but the prices listed are for your convenience. For promptparts service, cont...
Page 18 - TAMPERING IS DANGEROUS; IF YOU SMELL GAS, DON’T LIGHT IT; Do not try to light any appliance.
YOUR GAS CONTROL AND PILOT LIGHT SYSTEM Your gas control and pilot light system has asafety device whose purpose is to shut-off thegas supply to the appliance if the pilot light goesout. If you have trouble lighting the pilot orkeeping it lit, it may mean that this safety deviceis warning you that t...
Page 19 - LOUISVILLE TIN & STOVE COMPANY; LIMITED WARRANTY; TABLE A
LOUISVILLE TIN & STOVE COMPANY P.O. BOX 2767 - LOUISVILLE, KENTUCKY 40201-2767 LIMITED WARRANTY The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the periods p e c i f i e d h e r e i n , p r o v i d e d s a i d p r o d u c t i s i n s t a l l e d ,ope...