Page 2 - Trademarks and Copyrights:
FLAVORFUSION®/FLAVOROVERLOAD TRAINING MANUAL The products, technical information, and instructions contained in this manual are subject to change without notice. These instructions are not intended to cover all details or varia-tions of the equipment, nor to provide for every possible contingency in...
Page 3 - FlavorFusion®/FlavorOverload Training Manual; TABLE OF CONTENTS
FlavorFusion®/FlavorOverload Training Manual © 2004-2007, IMI Cornelius Inc. - i - Publication Number: TP01070 TABLE OF CONTENTS Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Theory of Operation . . . . . . . . . . . . . . ...
Page 6 - FlavorFusion® Training Manual; SYSTEM REQUIREMENTS; Indoor installation only
FlavorFusion® Training Manual Publication Number: TP01070 - 2 - © 2004-2007, IMI Cornelius Inc. SYSTEM REQUIREMENTS Dimensions (in): . . . . . . . . 29 x 30 x 39 (l x w x h). Height is measured to top of bin. Lid adds 3 in to height. Counter Weight (lb): . . . . . 320 (plus ice weight) Shipping Weig...
Page 7 - PROGRAMMING; Programming Mode Flashing Sequences; Dispense Type 1, Carbonated water dispense:; FIGURE 1
FlavorFusion®/FlavorOverload Training Manual © 2004-2007, IMI Cornelius Inc. - 3 - Publication Number: TP01070 PROGRAMMING NOTE: The programming mode is exactly the same for both brand and bonus keypads. To enter the programming mode, press and hold the two program buttons (see FIGURE 3) at the top ...
Page 8 - Setting Water Flow Rate; Enter programming mode for the valve; buttons until the flash pattern for all for buttons changes.
FlavorFusion® Training Manual Publication Number: TP01070 - 4 - © 2004-2007, IMI Cornelius Inc. Setting Water Flow Rate Setting the water flow rate will require a timed dispense. To accomplish this, the following procedure should be followed:1. Enter programming mode for the valve block by simultane...
Page 9 - Timed Dispense Procedure; Repeat for all syrups in valve bank.; Setting a Button to Dispense Non-carbonated Water Only
FlavorFusion®/FlavorOverload Training Manual © 2004-2007, IMI Cornelius Inc. - 5 - Publication Number: TP01070 FIGURE 3 Adjusting Syrup/Water Ratio (Brix) Timed Dispense Procedure 1. Enter programming mode for the valve block by simultaneously pressing and holding both programming buttons for 4 seco...
Page 10 - MECHANICAL; ISASSEMBLY; Control Box Components; FIGURE 4
FlavorFusion® Training Manual Publication Number: TP01070 - 6 - © 2004-2007, IMI Cornelius Inc. MECHANICAL D ISASSEMBLY Control Box Components FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 Ballast for Merchandiser Light 24 Volt Transformer (2) Starter Merchandiser Light Main Control Board/Agitator Timer Motor...
Page 11 - ALVE; FIGURE 8
FlavorFusion®/FlavorOverload Training Manual © 2004-2007, IMI Cornelius Inc. - 7 - Publication Number: TP01070 V ALVE R EMOVAL 1. Pull on retaining bracket (both sides) so the switch panel will rotate out of the way (see FIGURE 9). FIGURE 8 FIGURE 9 2. Unscrew the switch panel (one on each side). FI...
Page 14 - YSTEM
FlavorFusion® Training Manual Publication Number: TP01070 - 10 - © 2004-2007, IMI Cornelius Inc. S YSTEM P LUMBING D IAGRAM
Page 15 - LUMBING; ICE
FlavorFusion®/FlavorOverload Training Manual © 2004-2007, IMI Cornelius Inc. - 11 - Publication Number: TP01070 P LUMBING D IAGRAM 10.000 5.500 ICE CHUTE FLAVOR FUSION -16 BRAND 620920670 REV. 7 THIS EQUIPMENT M UST BE INSTALLED WITH ADEQUATE BACKFLOW PROTECTION TO COMPLY WITH APPLICABLE FEDERAL, ST...
Page 16 - CW; TO SOLENOID VALVES; INTERFACE BOARD DETAIL
FlavorFusion® Training Manual Publication Number: TP01070 - 12 - © 2004-2007, IMI Cornelius Inc. I NTERFACE B OARD AND H ARNESS P IN - OUT D ETAIL 12 11 10 9 8 7 6 5 4 3 2 1 C C C C CW C C PW S4 S3 S2 S1 CW PW S4 S3 S2 S1 TO SOLENOID VALVES INTERFACE BOARD DETAIL
Page 17 - OINT; WIRING
FlavorFusion®/FlavorOverload Training Manual © 2004-2007, IMI Cornelius Inc. - 13 - Publication Number: TP01070 P OINT -P OINT W IRING D IAGRAM 6.000 10.250 LED. ICE C UBE GRAPHIC TIME TIME WHT BLK RED 620920673 REV 5 ELECTRIC SHOCK HAZARD. DISCONNECT POWER BEFORE SERVICING UNIT. WIRING D IAGRAM FLA...
Page 18 - ADDER; WIRING LADDER SCHEMATIC 115V- FLAVOR FUSION
FlavorFusion® Training Manual Publication Number: TP01070 - 14 - © 2004-2007, IMI Cornelius Inc. L ADDER T YPE W IRING D IAGRAM L1 N BEV. X-FRMR INTERFACE BOARD-1 INTERFACE BOARD-2 INTERFACE BOARD-3 INTERFACE BOARD-4 INTERFACE BOARD-5 INTERFACE BOAR-6 24V 24V BALLAST LIGHT STARTER CARB MOTOR CARB MO...
Page 19 - ROUBLESHOOTING; system, stop dispensing, shut off the CO; If repairs are to be made to the electrical system, make sure
FlavorFusion®/FlavorOverload Training Manual © 2004-2007, IMI Cornelius Inc. - 15 - Publication Number: TP01070 T ROUBLESHOOTING IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to a product system, remove quick disconnec...