GENERAL UNCRATING AND HANDLING OF HEATER The Chromalox FXTH Flexible Tank Heater is designed for heat- ing viscous liquids in large steel, concrete or fibrous glass tanks withnormal manhole entry. Standard equipment with every heaterincludes flexible pipe and 14’ riser(s), two lifting cables, 4” hig...
PREPARATION OF TANK TO RECEIVE HEATER INSTALLATION OF HEATER ASSEMBLY IN TANK Manhole Cover 3/8” Min. 8 - 3/8” - 11 Drilled andTapped Equally SpacedHoles on 11-3/4” B.C. 22-1/2” 9-1/2” ± 1/4” Dia. HoleBy Customer ConduitOpening 13” Dia.(See Note 1)By Customer Figure B Figure C Machining of Manhole C...
INSTALLATION OF HEATER ASSEMBLY IN TANK (cont’d.) 5. Begin lowering heater into tank as per Figure G, Step 1 thru 3(end manhole) or Figure H, Step 4 thru 7 (center manhole). Oncethe heater has touched bottom, use pulling wire (front liftingcable) to pull heater toward far end of tank. 6. Before lowe...