Page 2 - optional; MECHANICAL SPECIFICATIONS; Depth; ON; the brewer is ready to brew the next batch of coffee.
2 SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. BC1 BC301 BC120 BC240 BC2 BC302 Volts 120/240 120/240 120 240 120/240 120/240 Watts 4100 4100 1800 3120 6200 6280 Amps 18 18 15 13 27 27 Wall Outlet (Receptacle) Power Cord CE202 – 30A optional 6-20R 6-20R 5-15R 6-15R 6-30R 6-30R All Brew Centers ...
Page 3 - INSTALLATION AND OPERATING INSTRUCTIONS
3 INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer. ASSEMBLY AND SET-UP...
Page 4 - INITIAL PRIMING
4 INITIAL PRIMING – Filling of Tank The BC Brewers are shipped with the Thermostat in the OFF position. Do not turn Thermostat to the ON position until the Brewer has been fully primed. a. Turn water supply on and check for leaks at the water inlet connections. Tighten compression fitting if necessa...
Page 5 - ADJUSTMENTS; After 15 seconds, push warmer/cycle stop switch to stop cycle.; clockwise; will; decrease; The BY-PASS valve is activated only when the; DUAL BYPASS VALVE
5 ADJUSTMENTS 1. BY-PASS FLOW VALVE ADJUSTMENTS Depending on the model number, the BC Brewers have been factory set to brew 12, 24 and/or 36 cups of coffee, with the BY-PASS adjusted for a 20% BY-PASS flow of brewing water for the 36 cup, brew output only. Since water hardness, the brand of coffee, ...
Page 7 - SPECIAL COMPONENTS TEST
SPECIAL COMPONENTS TEST 1) CHECK DISPENSE VALVES FOR LIME BUILD-UP ( Located inside top cabin ) Drain the water tank to just below the level of the Dispense Valves. Remove the Valves and clean. You can take these valves apart by hand as shown. Replace the assembly as needed. Replace the valve into t...
Page 8 - TROUBLESHOOTING GUIDE; proper; PROBLEM
8 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE ...
Page 9 - CLEANING AND SANITIZING; To prepare a sanitizing solution:; Carrier liners should be cleaned daily.; OFF; and the Warmer Deck has cooled down to room temperature.; CARE OF STAINLESS STEEL:
9 CLEANING AND SANITIZING SANITIZING: All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F). Note: Al...
Page 10 - PARTS IDENTIFICATION; DESCRIPTION; BC302 FRONT OPEN VIEW
10 PARTS IDENTIFICATION [ * RECOMMENDED SPARE PARTS] SINGLE UNITS BC1, BC301, BC120, BC240 TWIN UNITS BC2, BC302 ITEM P/N QTY P/N QTY DESCRIPTION 1 SF26A 1 SB49A 1 CABINET TOP COVER 2 --- N829A N892A N822A -- 1 1 1 ---- --- N815A N823A -- -- 1 1 SWITCH PANEL LABELS: BC120 & BC240 BC1 / BC2 BC301...
Page 11 - ITEM SPARE
11 TOP CABIN OPEN VIEW TOP CABIN - PARTS IDENTIFICATION [ * RECOMMENDED SPARE PARTS] ITEM SPARE PARTS SINGLE UNITS P/N QTY TWIN UNITS P/N QTY DESCRIPTION 1 * L656A 1 L656A 1 HI-LIMIT 2 * L499A M532A 1 1 L499A M523A 1 1 FLOAT SENSOR WITH RUBBER GASKET 3 * G367A G369A G286A 1 G367A G369AG286A 2 HEATER...
Page 12 - RECOMMENDED SPARE PARTS]; QTY
12 BOTTOM CABIN OPEN VIEW BOTTOM CABIN - PARTS IDENTIFICATION [ * RECOMMENDED SPARE PARTS] SPARE PARTS BC301-IT BC2-IT BC302-IT ITEM P/N QTY P/N QT Y DESCRIPTION 1 * L069A 1 L069A 1 POWER SWITCH 2 B083A 1 B083A 1 TERMINAL BLOCK 3 * CD257 1 CD257 1 WATER INLET VALVE 4 * C396A C395A 1 1 C396A C395A 1 ...
Page 13 - CARRIER ASS’Y
13 CARRIER ASS’Y 97208 [ * RECOMMENDED SPARE PARTS] Item Description Part # 1 * Handle, black 3” 02015 2 2 * * Hold Down Bracket Thumb Screw U833A M299A 3 * * Carrier Cover S.S. Gasket, Cover Carrier U811A M294A 4 Label NG47A 5 Screw P808A 6 * Faucet Guard U812A 7 * Faucet & Shank Ass’y 8” 99461...
Page 14 - RED; HI LIMIT; FAUCET & SHANK ASS’Y 99461
14 WHITE RED BLACK BREW CIRCUIT BREW VALVE R W B L L2 N FUSE 6 AMP. RED BLK GND L1 L1 LOAD REFILL CIRCUIT PROBE N HI LIMIT BLK D C.G. BC-1E 120/240 3 WIRES + GROUND 3100 WATTS 14A 1 PH 60Hz C.G. - D FAUCET & SHANK ASS’Y 99461
Page 15 - CUP
15 BC120E 2 WIRES+GRD 1800W 15A 1PH A C.G. BC240E 2 WIRES+GRD 3120W 13A 1PH C.G. - A BLACK WHITE BC-240E DUAL BREWTIME BC-120E DUAL BREWTIME RED WARMER L2 S L1 SW2 SW3 I2 I1 12 CUP 24 CUP BREW INDICATOR LIGHT HI LIMIT FUSE 6 AMP. BLK BLK GND L1 N FLOAT SWITCH L1 LOAD PROBE N
Page 16 - REFILL CIRCUIT; BC-301E TRIPLE BREW TIME; BREW CIRCUIT
16 N L1 REFILL CIRCUIT HI LIMIT BLK RED WHITE BLACK 8 9 11 FUSE 6 AMP. RED BLK BLK N L2 GND L1 INLET VALVE PROBE LOAD C C.G. BC-301E 120/240 3 WIRES+GND 4140W 18A 1PH 60HZ BC-301E TRIPLE BREW TIME BREW CIRCUIT 10 12 24 36 C.G. - C
Page 17 - BC-2E SINGLE BREW TIME
17 C C.G. BC-2E 120/240 3 WIRE+GRD 6230W 26A 1PH 60HZ C.G. - C PROBE PROBE L1 LOAD N HI LIMIT BLK BLACK WHITE RED L BC-2E SINGLE BREW TIME W R B GND RED BLK L2 N L1 L B W R