Carrier WEATHER MARKER 58VCA- Manuals
Carrier WEATHER MARKER 58VCA– User Manual in PDF format online.
Manuals:
User Manual Carrier WEATHER MARKER 58VCA
Summary
NOTE: Use No. 18 AWG color-coded, insulated (35°C min) wire. If thermostats are to be located more than 100 ft from theWeatherMaker Two-Zone Center as measured along the controlvoltage wires, use 16 AWG colored-coded wires to avoid exces-sive voltage drop. All wiring is run back to the WeatherMakerT...
Failure to properly install the bypass damper can causepermanent damage to the HVAC equipment. For single-speedfurnace applications, the bypass air must never exceed 25percent. Step 6—Install Duct Temperature Sensor Locate the duct temperature sensor in the main supply trunk afterthe bypass damper a...
Fig. 12—WeatherMaker Two-Zone Circuit Board A93524 3 ThermostatZone 2 Y 2 Y 1 RW 1 W 2 C G ThermostatZone 1 Y 2 Y 1 R W 1 W 2 C Sensors DX Duct Equipment R c B O Y 2 Y 1 W 1 W 2 G R h 24 VACPower 24 v CLOPC Zone 1 Damper Zone 2 Damper CLOPC G B D 1 F A E C K J I H L M N 2 3 ZONE 1 I/O CENTER CONNECT...