Page 2 - Fig. 2—Damper Motor Positioning; Fig. 4—Round Metal Ductwork

NOTE: Use No. 18 AWG color-coded, insulated (35°C min) wire. If thermostats are to be located more than 100 ft from theWeatherMaker Two-Zone Center as measured along the controlvoltage wires, use 16 AWG colored-coded wires to avoid exces-sive voltage drop. All wiring is run back to the WeatherMakerT...

Page 4 - Table 1—Available Heating and Cooling Stages Versus System Type; Energized

Failure to properly install the bypass damper can causepermanent damage to the HVAC equipment. For single-speedfurnace applications, the bypass air must never exceed 25percent. Step 6—Install Duct Temperature Sensor Locate the duct temperature sensor in the main supply trunk afterthe bypass damper a...

Page 5 - Fig. 12—WeatherMaker Two-Zone Circuit Board

Fig. 12—WeatherMaker Two-Zone Circuit Board A93524 3 ThermostatZone 2 Y 2 Y 1 RW 1 W 2 C G ThermostatZone 1 Y 2 Y 1 R W 1 W 2 C Sensors DX Duct Equipment R c B O Y 2 Y 1 W 1 W 2 G R h 24 VACPower 24 v CLOPC Zone 1 Damper Zone 2 Damper CLOPC G B D 1 F A E C K J I H L M N 2 3 ZONE 1 I/O CENTER CONNECT...