Page 3 - Burner sight glass for viewing burner flame.
3 58MVB NOTES: 1. The 58MVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory-authorized and listed accessory conversion kit. 2. Control location and actual controls may be different than shown above. Burner sight glass for viewing burner flame. B...
Page 5 - Thermostat and Zoning Control Options
5 58MVB Carrier accessories * continued UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 ADVANCED PRODUCT MONITOR (software and hardware to link pc laptop to control board) KGAFP0201APM X X X X X X ECM CONTROL REPLACEMENT MODULE - 1/2 HP HK44EA120 X X X ECM CONTROL REPLACEMENT MODULE - 1 HP HK52E...
Page 6 - CONTROL CENTER
6 58MVB A93086 CONCENTRIC VENT (DIRECT VENT / 2-PIPE ONLY) A concentric vent kit allows vent and combustion-air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the otherallowing venting through the inner pipe and combustion air to be drawn in through the out-er ...
Page 7 - ama
7 58MVB ® A97152 ELECTRONIC OR MECHANICAL AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keep-ing carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. A97432 CONTROLS: THERMOSTATS AND ZONING Available in progr...
Page 8 - Physical data; Performance data
8 58MVB Physical data UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 DIRECT-DRIVE MOTOR Hp (ECM) 1/2 1/2 1/2 1 1 1 MOTOR FULL LOAD AMPS 7.7 7.7 7.7 12.8 12.8 12.8 RPM (Nominal) — SPEEDS Variable 250 — 1300 BLOWER WHEEL DIAMETER X WIDTH (In.) 11 x 10 10 x 7 11 x 10 11 x 10 11 x 10 11 x 10 FILTER...
Page 11 - Dimensions; CONDENSATE TRAP
11 58MVB Dimensions COMBUSTION-AIR PIPE FOR NON-DIRECT (1-PIPE) VENT APPLICATION (SIZES 040 THROUGH 120 ONLY) CONCENTRIC VENT (DIRECT VENT/2-PIPE ONLY) (ALL MODEL SIZES) CONDENSATE TRAP 1 ⁄ 2 OD INDUCER HOUSINGDRAIN CONNECTION 1 ⁄ 4 OD COLLECTOR BOX TOTRAP RELIEF PORT 5 ⁄ 8 OD COLLECTOR BOXDRAIN CON...
Page 13 - DOWNFLOW SUBBASE
13 58MVB DIMENSIONS (In.) * The plenum should be constructed 1/4-in. smaller in width and depth than the plenum dimensions shown above. FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING * FLOOR OPENING HOLE NO. FOR WIDTH ADJUSTMENT A B C D 17-1/2 Furnace with or without Cased Coil ...
Page 16 - Continued
16 58MVB Maximum Allowable Pipe Length (Ft) Continued ALTITUDE UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS Termination Type Pipe Dia (IN.)* Pipe Dia (IN.)* 1 2 3 4 5 6 5001 to 6000‡ 40,000 2 Pipe or 2-In. Concentric 1-1/2 1-1/2 3 7 3 2 27 22 17 12 2 ...
Page 19 - Clearance to combustibles; MINIMUM INCHE; IN
19 58MVB Clearance to combustibles Cle a r a nce in inche s . Vent cle a r a nce to com bus ti b le s 0". Thi s f u rn a ce i s a pproved for UPFLOW, DOWNFLOW a nd HORIZONTAL in s t a ll a tion s . * BO T T O M 0" Ø 3 " 0" § 0" T O P/ PLE N U 1" 0" § 3 0 MIN ALL PO S ITIO...
Page 20 - Typical installations; Basement — Upflow Application
20 58MVB Typical installations Basement — Upflow Application A05064 Closet — Downflow Application A05065 COMBU S TION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GA S -FIRED WATER HEATER ELECTRONICAIR CLEANER AIRFLOW FRONT OFFURNACE COMBU S TION AIR INLET(NON...
Page 21 - Attic — Horizontal Application; Crawlspace — Horizontal Application
21 58MVB COMBU S TION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDEN S ATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE A05066 DIRECT VENT/2-PIPE APPLICATION) COMBU S TION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) Attic — Horizontal Application A05066 Craw...
Page 22 - Guide specifications
Copyright 2006 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 Printed in U.S.A. edition date: 01/06 Manufacturer reserves the right to change, at any time, specifications or designs without notice and obligations Catalog No: 58MVB-1PDRev.A Replaces: 58MVB-1PD GENERALSystem Description F...