  • Page 3 – Burner sight glass for viewing burner flame.
  • Page 5 – Thermostat and Zoning Control Options
  • Page 6 – CONTROL CENTER
  • Page 7 – ama
  • Page 8 – Physical data; Performance data
  • Page 11 – Dimensions; CONDENSATE TRAP
  • Page 13 – DOWNFLOW SUBBASE
  • Page 16 – Continued
  • Page 19 – Clearance to combustibles; MINIMUM INCHE; IN
  • Page 20 – Typical installations; Basement — Upflow Application
  • Page 21 – Attic — Horizontal Application; Crawlspace — Horizontal Application
  • Page 22 – Guide specifications
Loading the manual

INFINITY™ 96 MODEL 58MVB
DELUXE 4-WAY MULTIPOISE VARIABLE-SPEED
CONDENSING GAS FURNACE

Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data

Comfort Heat™ technology,
the ultimate in
heating comfort . . .

The Carrier Infinity™ 96 with Com-
fortHeat™ technology achieves the opti-
mum combination of comfort and
efficency.
The Infinity™ 96 achieves industry-
leading ultra-high efficiency at up to
96.6 percent Annual Fuel Utilization Ef-
ficiency (AFUE). Efficient performance
is enhanced through the variable-speed
design. To maintain ideal comfort, Com-
fortHeat™ technology automatically ad-
justs the heating level, maximizing the
use of low heating levels that produce
near silent furnace operation while meet-
ing the exact heating needs. This unit is
designed to keep the indoor temperature
within 1 degree of the thermostat set-
point. Because it operates in low heat
most of the time, the Infinity™ 96 uses
up to 80% less power than single-capac-
ity furnaces.
In addition to providing ultimate com-
fort, the Infinity™ 96 has a sealed com-
bustion system. This system brings
combustion air to the furnace and vents
flue gases outside the furnace in a safe
manner. Because it is sealed, operational
noise is minimal. A sealed combustion
system also means fewer cold drafts and
less air infiltration.
Quality materials are the key behind the
Infinity™ 96’s outstanding perfor-
mance. Carrier stands behind quality.
We offer lifetime warranty protection*
on the heat exchangers, the heart of the
Infinity™ 96. The rest of the unit is
backed by a limited 5-year warranty.
The Infinity™ 96 is available in 6 heat/
airflow combinations. The unit has a
4-way multipoise design and can be
installed in upflow, downflow, or

A05069

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Burner sight glass for viewing burner flame.

3 58MVB NOTES: 1. The 58MVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory-authorized and listed accessory conversion kit. 2. Control location and actual controls may be different than shown above. Burner sight glass for viewing burner flame. B...

Page 5 - Thermostat and Zoning Control Options

5 58MVB Carrier accessories * continued UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20 ADVANCED PRODUCT MONITOR (software and hardware to link pc laptop to control board) KGAFP0201APM X X X X X X ECM CONTROL REPLACEMENT MODULE - 1/2 HP HK44EA120 X X X ECM CONTROL REPLACEMENT MODULE - 1 HP HK52E...

Page 6 - CONTROL CENTER

6 58MVB A93086 CONCENTRIC VENT (DIRECT VENT / 2-PIPE ONLY) A concentric vent kit allows vent and combustion-air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the otherallowing venting through the inner pipe and combustion air to be drawn in through the out-er ...