Page 2 - INSPECT EQUIPMENT; Step 2—Install on a Solid, Level Mounting Pad; Unit must be level to within; Step 3—Clearance Requirements; FURNACE COILS; Fig. 2—Connecting Tubing Installation

INSPECT EQUIPMENT File claim with shipping company prior to installation if shipmentis damaged or incomplete. Locate unit rating plate on unit servicepanel. It contains information needed to properly install unit.Check rating plate to be sure unit matches job specifications. Step 2—Install on a Soli...

Page 3 - Fig. 4—Typical TXV Installation; Fig. 5—Positioning of Sensing Bulb

4. Position sensing bulb on horizontal portion of suction tube adapter. Secure using supplied hardware. 5. Insulate bulb after installation. (See Fig. 5.) 6. Leak check all connections. FAN COILS If indoor unit (fan coil) comes factory equipped with a bi-flowhard shutoff TXV, no TXV change is requir...

Page 4 - Step 10—Make Electrical Connections; Table 2—Accessory Usage; PISTON BODY

SWEAT CONNECTION To avoid valve damage while brazing, service valves must bewrapped in a heat-sinking material such as a wet cloth. 1. Remove plastic retainer holding outdoor piston in liquid service valve. 2. Locate adapter tube shipped with unit. 3. Install strainer in adapter tube and connect tub...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8

Summary

Page 2 - Fig. 2—Connecting Tubing Installation; UNIT

INSTALLATION Step 1—Check Equipment and Job Site UNPACK UNIT Move to final location. Remove carton, taking care not to damageunit. INSPECT EQUIPMENT File claim with shipping company prior to installation if shipmentis damaged or incomplete. Locate unit rating plate on unit servicepanel. It contains ...

Page 3 - Step 7—Check Outdoor AccuRater® Piston; Fig. 4—Typical TXV Installation; Fig. 5—Positioning of Sensing Bulb; SENSING BULB; Fig. 6—Defrost Thermostat Location; FEEDER TUBE

If TXV installation is required, remove existing AccuRater® fromindoor coil. Refer to Figs. 4 and 5 and install TXV kit as follows: 1. Install suction tube adapter. 2. Install liquid flare-to-sweat adapter. 3. Connect external equalizer tube to fitting on suction tube adapter. 4. Position sensing bu...

Page 4 - Step 10—Make Electrical Connections; PISTON BODY

OUTDOOR UNIT CONNECTED TO FACTORY APPROVEDINDOOR UNIT Outdoor unit contains correct system refrigerant charge for opera-tion with indoor unit of same size when connected by 15 ft offield-supplied or factory accessory tubing. Check refrigerantcharge for maximum efficiency. REFRIGERANT TUBING Connect ...