Page 2 - To; ensure proper closing, install the bypass valve; q 2pJ

UNITS and (See Fig. 1.) Line Connect the field-supplied line to the factory-provided stubs in the discharge line the circuit no. 1 compressor and in the no. line, between expansion valve and cooler (stubs are sealed from factory). Bypass Valve Install the valve in the line as close to the cooler as ...

Page 3 - Wires between field-installed components and unit; Two

Step 3 Dehydrate and Recharge Circuit W h e n piping has been completed, leak test the assemblyand replace the filter drier, or core(s) for circuit no. 1.On single-compressor chillers 15,025 and 030 for 60 Hz, 020,025 for 50 Hz; 30GT) the filter drier itself must be replaced. After core (or drier) r...

Page 4 - A . C O N N E C T I O N S F O R S I N G L E - C O M P R E S S O R; Hot Gas Bypass Field Wiring; OPERATION AND ADJUSTMENT; Hot Gas Bypass; COMBINED LEGEND

ALL FLOTRONIC UNITS Units require control r e l a y s tained R) and Time Delay Module. They may be ob- rom your Carrier distributor under the following Carrier Part Numbers: and R2 R 3 Time Delay Module 115-v 24-v DPDTDPDT H N 6 1 K K 0 4 0 DPDT UNITS T H R O U G H 060 ( E x c e p t 020, 60 Hz, and ...

1 Page 1
2 Page 2
3 Page 3
4 Page 4

Summary

Page 2 - To; ensure proper closing, install the bypass valve; q 2pJ

UNITS and (See Fig. 1.) Line Connect the field-supplied line to the factory-provided stubs in the discharge line the circuit no. 1 compressor and in the no. line, between expansion valve and cooler (stubs are sealed from factory). Bypass Valve Install the valve in the line as close to the cooler as ...

Page 3 - Wires between field-installed components and unit; Two

Step 3 Dehydrate and Recharge Circuit W h e n piping has been completed, leak test the assemblyand replace the filter drier, or core(s) for circuit no. 1.On single-compressor chillers 15,025 and 030 for 60 Hz, 020,025 for 50 Hz; 30GT) the filter drier itself must be replaced. After core (or drier) r...

Page 4 - A . C O N N E C T I O N S F O R S I N G L E - C O M P R E S S O R; Hot Gas Bypass Field Wiring; OPERATION AND ADJUSTMENT; Hot Gas Bypass; COMBINED LEGEND

ALL FLOTRONIC UNITS Units require control r e l a y s tained R) and Time Delay Module. They may be ob- rom your Carrier distributor under the following Carrier Part Numbers: and R2 R 3 Time Delay Module 115-v 24-v DPDTDPDT H N 6 1 K K 0 4 0 DPDT UNITS T H R O U G H 060 ( E x c e p t 020, 60 Hz, and ...