Page 2 - P a g e; CONTENTS; INSTALLATION AND GAS CONNECTION
P a g e | 2 web: brohn.com.au CONTENTS 1. PACKAGE ................................................................................................................................................................. 4 IMPORTANT - CHECK FOR ANY DAMAGE OR MARKS ...............................................
Page 4 - IMPORTANT - CHECK FOR ANY DAMAGE OR MARKS; at the delivery time; HANDLING
P a g e | 4 web: brohn.com.au 1. PACKAGE IMPORTANT - CHECK FOR ANY DAMAGE OR MARKS Please thoroughly inspect your goods at the delivery time , if you notice any damage to your goods: Please notify the delivery team at the time of delivery and do NOT accept damaged product . Please notify us imme...
Page 5 - IMPORTANT INFORMATION; This appliance is designed for domestic household use.; CHILD SAFETY; It is recommended for children not to play with the appliance.
P a g e | 5 web: brohn.com.au 2. SAFETY WARNINGS IMPORTANT INFORMATION Your safety is of the utmost importance to us. Please make sure that youread this instruction booklet before attempting to install or use theappliance. If you are unsure of any of the information contained in thisbooklet, please ...
Page 6 - GENERAL SAFETY
P a g e | 6 web: brohn.com.au GENERAL SAFETY The appliance should only be installed and connected by a licensed qualifiedprofessional. Care should be taken to ensure that the units and work surfaces that you build theappliance into, meet with the relevant standards. DURING USE Care should be t...
Page 7 - Product specifications:; Front control operation
P a g e | 7 web: brohn.com.au 3. SPECIFICATIONS 3.1 BRGC3001BLK Product specifications: A = 1 x 14.4 MJ/h triple crown (wok) burner (NG)B = Control panel o Front control operation o Automatic ignition o Metal pan stands o Flame failure safety device on each burner 31 0 49 0 26 8
Page 8 - Side control operation
P a g e | 8 web: brohn.com.au 3.2 BRGC6040DSS Product specifications: A = 1 x 10.8 MJ/h rapid burner (NG)B = 2 x 6.5 MJ/h semi-rapid burners (NG)C = 1 x 3.6 MJ/h auxiliary burner (NG)D = Control panel o Side control operation o Automatic ignition o Metal pan stands o Flame failure safety device on e...
Page 13 - ELECTRICAL DETAILS
P a g e | 13 web: brohn.com.au ELECTRICAL DETAILS Rated Voltage: 220 - 240 Vac 50 / 60 Hz Supply Connection: 3A Max Rated Inputs: 0.0008 kW Mains Supply Lead: 3 core x 0.75mm² (Type RR-F <HAR> marked) GAS DETAILS Connection: Rp ½ (ISO R7) Type: Natural Gas (1.0 KPa) LPG (2.75KPa)
Page 14 - BEFORE FIRST USE; be removed before use.; SWITCHING THE HOB ON; Gas off; AUTOMATIC IGNITION WITH FLAME FAILURE SAFETY DEVICE
P a g e | 14 web: brohn.com.au 4. USING THE GAS HOB BEFORE FIRST USE IMPORTANT: Any film or stickers that are present on the cooktop surface should be removed before use. The cooktop surface should be cleaned regularly (see “Care and Maintenance” section). SWITCHING THE HOB ON The following symbols ...
Page 15 - ENERGY SAVING TIPS; Wok
P a g e | 15 web: brohn.com.au You should hold down the control knob for 20 seconds after the flame on the burnerhas lit. After this 20 second interval, turn the control knob to your required setting betweenthe maximum and minimum setting symbols. To switch the burner off, turn the control kno...
Page 16 - CLEANING THE HOB TOP
P a g e | 16 web: brohn.com.au 5. CLEANING Cleaning operations must only be carried out when the hob is cool. The appliance should be disconnected from your mains supply beforecommencing any cleaning process. CLEANING THE HOB TOP Any residues that remain on the hob top surface from cleaning agents w...
Page 17 - MAINTAINING THE CAST IRON PAN STANDS; attempt to touch them.
P a g e | 17 web: brohn.com.au MAINTAINING THE CAST IRON PAN STANDS IMPORTANT: Make sure that the hob surface and pan stands have cooled before you attempt to touch them. Wipe the pan stands over with a soft, damp cloth washed in warm soapy water. Using a paper towel, thoroughly dry the pan stan...
Page 18 - LEGAL; fitter in accordance with the local standards and regulations.; POSITIONING; of 85°C above the ambient temperature of the room it is located in.
P a g e | 18 web: brohn.com.au 6. INSTALLATION AND GAS CONNECTION LEGAL The installation must be carried out by a licensed installer and professional gas fitter in accordance with the local standards and regulations. POSITIONING The adjacent furniture must be able to withstand a minimum temperature ...
Page 19 - ALL MODELS
P a g e | 19 web: brohn.com.au 400 mm between the hob surface, providing that the underside of the horizontal surface is in line with the outer edge of the hob. If the underside of the horizontal surface is lower than 400 mm, then it must be at least 50 mm away from the outer edges of the hob. 5...
Page 21 - Ensure that the ventilation rules and regulations are followed.; DUAL GAS REGULATOR VALVE INTRODUCTION; choose other appropriate sealing methods.
P a g e | 21 web: brohn.com.au This hob is not fitted with a device for discharging the products of combustion. Ensure that the ventilation rules and regulations are followed. The walls behind and near the hob should be resistant to heat, steam and condensation. Remember that the quantity of a...
Page 22 - GAS SAFETY (INSTALLATION AND USE) REGULATIONS
P a g e | 22 web: brohn.com.au WARNING: Regulator valve outlet pressure is set at the factory, please do not adjust in order to avoid the occurrence of safety accidents. Turn off the gas source for any work on gas appliances. If you find any fault of the regulator valve operation, stop use and c...
Page 23 - pressure complies with the gas standards in force.
P a g e | 23 web: brohn.com.au Gas pressure may be checked on a semi-rapid hob burner. Remove the appropriate injector and attach a test nipple. Light the other burners and observe that the gas pressure complies with the gas standards in force. IMPORTANT: On completion carry out a gas soundness ...
Page 24 - Auxiliary; MINIMUM FLOW ADJUSTMENT FOR HOB GAS TAPS
P a g e | 24 web: brohn.com.au 0.72 Semi-rapid 6.6 3.24 0.53 Auxiliary 3.7 1.8 Reassemble all burners carefully; in particular you should ensure that the flame spreader is correctly placed on the burner. IMPORTANT: The minimum flow adjustment process must be completed before the appliance is use...
Page 25 - IMPORTANT: WHEREVER THIS APPLIANCE IS INSTALLED, AT HOME, IN MARINE; GAS TAP MAINTENANCE; rotate several times.; ELECTRICAL CONNECTION; rating plate corresponds with your mains supply voltage.
P a g e | 25 web: brohn.com.au IMPORTANT: WHEREVER THIS APPLIANCE IS INSTALLED, AT HOME, IN MARINE CRAFT OR CARAVAN, IT SHALL NOT BE USED AS A SPACE HEATER. GAS TAP MAINTENANCE These maintenance operations MUST ONLY be carried out by a licensed gas fitter.IMPORTANT: Before carrying out any maintenan...
Page 26 - REPLACING THE MAINS SUPPLY CABLE
P a g e | 26 web: brohn.com.au ○ Cable type: H05 RRF 3 core x 0.75 mm³ (Type RR-F <HAR> marked). ○ The mains supply cable and plug are supplied with this product. REPLACING THE MAINS SUPPLY CABLE If the mains supply cable is damaged, then it must be replaced by a licensed electrician and at ap...
Page 28 - keep the receipt; protection, please record installer’s details:
P a g e | 28 web: brohn.com.au 8. CUSTOMER CARE Please be advised that without the proof of purchase, your warranty may not be valid, keep the receipt . STORE NAME/CONTACT DETAILS: ............................................... PURCHASE DATE: ...........................................................