Page 2 - READ AND SAVE THESE INSTRUCTIONS; WARNING; MODEL; ALL INSTALLATIONS; PLAN THE INSTALLATION
2 READ AND SAVE THESE INSTRUCTIONS WARNING Refrigeration and Air Conditioning Engi- neers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall, or ceil- ing, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7....
Page 3 - guide hole
3 PREPARE THEINSTALLATION LOCATION ROOF INSTALLATIONS WALL INSTALLATIONS 2" 29-1/2" 2" 2 5 " 7" PREPARE THEINSTALLATION LOCATION 1. Locate the blower on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (T.V. leads, ...
Page 4 - ROOF INSTALLATIONS; INSTALL THE BLOWER; WALL INSTALLATIONS
4 INSTALL THE BLOWER ROOF INSTALLATIONS INSTALL THE BLOWER WALL INSTALLATIONS 1. Remove the cover and screws.2. Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box. 3. Remove roofing nails from shingles around the TOP and SIDES of the cut- out area only.Care...
Page 5 - WARRANTY; BROAN ONE YEAR LIMITED WARRANTY
5 WARRANTY BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRAN- TIES, EXPRESS OR IMPLIED, INCL...
Page 6 - CLEANING
6 1 2 3 4 5 6 7 8 10 11 12 13 13 14 15 16 17 18 18 19 15 20 9 SERVICE PARTS MODEL EB15 USE AND CARE Disconnect electrical power sup- ply and lock out service panel be- fore cleaning or servicing this unit. CLEANING R e m o v e c o v e r a n d c a r e f u l l y vacuum blower and inside of hous- ing. ...
Page 7 - PARA USARSE CON LAS COMPANAS
BEST BY BROAN, P.O. Box 140, HARTFORD, WI 53027 Modelo EB15 VENTILADOR DE MONTAJE EXTERIOR PARA USARSE CON LAS COMPANAS “BEST BY BROAN” DE ESTUFA, SERIES K210A O K260A
Page 8 - LEA Y CONSERVE ESTAS INSTRUCCIONES; ADVERTENCIA; INSTALADOR: Deje este manual con el usuario.; TODAS LAS INSTALACIONES; PLANEAMIENTO DE LA INSTALACION; MODELO VOLTIOS; INSTALACIÓN
8 LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA (NFPA por sus siglas en Inglés), y la Sociedadamericana de ingenieros de calefacción, refrig-eración y aire acondicionado (ASHRAE por sussiglas en Inglés), y los códigos de las autoridadeslocales. 5. Cuande corte o taladre en una pared o techo, no dañ...
Page 9 - orificio guía; INSTALACIONES DE TECHO; o r i f i c i o g u í a; diámetro
9 2 5 " 6 3 , 5 c m 2 9 2 9 ½ " 7 4 , 9 c m 1 4 1 1 / 1 6 " 3 7 , 3 c m Montante de la pared Orificio de 11" de 11" (27,9 cm) de diá. 2 0 " 5 0 , 8 c m Orificio de 1 Orificio de 1¼" (3,2 cm) de diá. 3" 7 , 6c m Ø Ø Ø Ø QUITE EL FORRO Orificio guía(centrado entre losmo...
Page 11 - GARANTIA; GARANTÍA BROAN LIMITADA POR UN AÑO
11 GARANTIA GARANTÍA BROAN LIMITADA POR UN AÑO Broan garantiza al consumidor comprador original de sus productos que dichos productos carecerán de defectos en materiales o en mano de obra por un período de un año a partir de la fecha original de compra. NO EXISTEN OTRAS GARANTÍAS, EXPRESAS O IMPLÍCI...
Page 12 - PARTES DE SERVICIO; CLAVE; USO Y CUIDADO; LIMPIEZA
12 1 2 3 4 5 6 7 8 10 11 12 13 13 14 15 16 17 18 18 19 15 20 9 PARTES DE SERVICIO MODELO EB15 CLAVE PARTE NO. NO. DESCRIPCION 1 98009538 Cubierta 2 99100531 Sello de espuma 3 98009539 Soporte del motor 4 98009541 Aleta del regulador de tiro (se req. 2) 5 99140145 Resorte del regulador de tiro (se re...
Page 13 - À UTILISER AVEC LES HOTTES “BEST BY BROAN”
BEST BY BROAN, P.O. Box 140, HARTFORD, WI 53027 Modèle EB15 VENTILATEUR À MONTAGE EXTÉRIEUR À UTILISER AVEC LES HOTTES “BEST BY BROAN” DE SÉRIE K210A OU K260A
Page 14 - LIRE ET CONSERVER CES INSTRUCTIONS; SPÉCIFICATIONS; MODÉLE; PLANNIFICATION DE L’INSTALLATION; TOUTES LES INSTALLATIONS
14 AVERTISSEMENT de la réfrigération et de la climatisation, et lesautorités localaes en matière de normes). 5.Lorsque vous coupez dans un mur ou loursque vous le percez, ne pas endommager les filsélectiques et les autres éléments utilitaires quis’y touvent. 6. Les ventilateurs à conduit doivent tou...
Page 15 - chevrons du toit; INSTALLATIONS SUR UN TOIT; trou de; INSTALLATIONS SUR UN MUR
15 2 5 p o 6 3 , 5 c m Che vr on 3 po 7 , 6c m Ø Ø Ø Ø 2 9 ½ p o 7 4 , 9 c m 2 0 p o 5 0 , 8 c m 1 4 1 1 / 1 6 p o 3 7 , 3 c m 1 4 5 / 8 p o 3 7 , 1 c m ENLEVER LES BARDEAUX Trou de 1¼ po (3,2 cm) Avant-trou(centré entre les chevrons) Trou de 11 po (27,9 cm) 1 4 1 1 / 1 6 p o 3 7 , 3 c m 2 0 p o 5 0...
Page 16 - INSTALLATIONS SUR LE TOIT; INSTALLATION DU VENTILATEUR; INSTALLATIONS SUR LE MUR
16 1. Enlevez le couvercle et les vis.2. Fixez un connecteur de câble adéquat portant l’homologation U.L. dans le trou arrière de las boîte de câblage. 3. Enlevez les clous à toiture des bardiaux entourant uniquement le HAUT et les CÔTÉS de l’ouverture. Soulevez soigneusement les bardiaux afin de po...
Page 17 - GARANTIE LIMITÉE D ́UN AN DE BROAN
17 GARANTIE LIMITÉE D´UN AN DE BROAN Broan garantit à l´acheteur consommateur original de ses produits qu´ils sont exempts de défauts dans les matières premières ou la main-d´oeuvre pour une période d´un an à compter de la date d´achat original. IL N´Y A PAS D´AUTRES GARANTIES, EXPRIMÉES OU IMPLICIT...
Page 18 - USAGE ET ENTRETIEN; NETTOYAGE; PIÈCES DE RECHANGE
18 1 2 3 4 5 6 7 8 10 11 12 13 13 14 15 16 17 18 18 19 15 20 9 N O N O REPÈRE PIÈCE DESCRIPTION 1 98009538 Couvercle 2 99100531 Joint de mousse 3 98009539 Support de moteur 4 98009541 Clapet (2 néces.) 5 99140145 Ressort de clapet (2 néces.) 6 98009537 Grille 7 99080479 Ensemble. du ventilateur 8 99...