Page 3 - INTERNAL BLOWERS
- 3 - HL0099 RMP SERIESBACKSPLASH (S TAINLESS STEEL WALL COVERING WITH WARMING SHELVES . O PTIONAL ) M ODEL 427 (4½” X 18½” TO 10” ROUND , 6” HIGH - LATERAL M ODEL 423 (4½” X 18½” TO 10” ROUND - VERTICAL M ODEL 424 (4½” X 18½” TO 10” ROUND - HORIZ . FRONT / REAR M ODEL 454 (4½” X 18½” TO 10” ROUND -...
Page 4 - IN-LINE AND EXTERIOR BLOWERS
- 4 - HL0100 - E60000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLOWERS RMP S ERIES B ACKSPLASH (S TAINLESS S TEEL WALL COVERING WITH WARMING SHELVES . O PTIONAL ) E60000 SERIES HOOD 332KR IN - LINE AND EXTERIOR BLOWER ROUGH - IN KIT ( SUPPLIED WITH HOOD ) M ODEL 418 10” R D ADJUSTABLE ELBOW M...
Page 5 - SELECT BLOWER OPTION AND INSTALLATION TYPE
- 5 - 1. SELECT BLOWER OPTION AND INSTALLATION TYPE 1.2 D UCTED I NSTALLATION The Broan Elite E60000 Series range hood includes many configurations: hoods with single or double internal blowers(included with the hood), or hoods using external blowers. For this last category, the Broan Elite E60000 S...
Page 6 - MINIMUM AND MAXIMUM DISTANCE; CAUTION
- 6 - Remove the installation kit from inside the hood. Make sure that the following items are included: -Wood strip (attached to back of hood) -Installation manual -Accessories including: • Baffle filters: 30” and 36” hoods comes with 3 baffle filters; 42” and 48” hoods comes with 4 baffle filters ...
Page 7 - PREPARE THE INSTALLATION; INSTALL BACKSPLASH
- 7 - 3. PREPARE THE INSTALLATION (CONT’D) Cut-out the openings for duct ( A ) and power cable ( B ), in cabinet or wall, according to the direction of discharge chosen. See figures below. NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall...
Page 8 - REMOVE FILTERS AND THE GREASE DRIP RAIL; REMOVE THE ADAPTER
- 8 - 5. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY) Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below. V ERTICAL DISCHARGE H ORIZONTAL DISCHARGE 6. REMOVE FILTERS AND THE GREASE DRIP RAIL A. Remove tape on filt...
Page 10 - INSTALL WOOD MOUNTING STRIP; INSTALL AEE OPTIONAL SOFFIT CHIMNEY
- 10 - 1. Drywall2. Wood mounting strip3. Flat head screw 4. Wall anchor location5. Back of hood outline6. Wall studs 10. INSTALL WOOD MOUNTING STRIP Measure and mark a level line on wall above cooktop location for the woodmounting strip (see illustration beside and under step 2). Remove wood mounti...
Page 11 - CONNECT THE WIRING; WARNING
- 11 - 14. ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY) Run power cable to installation location. For ducting through top of hood, existingplate remains in place on inside back of hood. For ducting through back of hood, remove existing plate from inside back of hoodand remove the rough-in p...
Page 12 - REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS; INSTALL LIGHT BULBS; INSTALL THE BLOWER; Do not plug the 2 cords together.
- 12 - Reinstall grease drip rail. The illustration beside shows how to reinsert the greasedrip rail into the range hood. 17. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS HD0244 NOTE:Assemble the metal handles to the filters, using provided no. 8-32 x 1/4” screws, before installing them in the hood...
Page 14 - WARRANTY
- 14 - COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob ( 1 ) controls the halogen lights (OFF - low intensity - high intensity). BLOWER The blower is operated using two controls. Use the on/off rocker switch ( 3 ) to start and stop the blower. When turned on, the blower indicator ( 2 ) turns on ...