Page 2 - Important Safeguards
EN | 2 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Important Safeguards Important Safeguards 1. Read, Follow, and Retain Instructions - All safety and operating instructions should be read andfollowed before operating the unit. Retain instructionsfor future reference. ...
Page 3 - For Indoor Product; - Do not use this unit near; For Outdoor Product; - An outdoor system should not be; For Rack-mount Product; - This unit should not be placed in a; Safety Precautions
EN | 3 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Safety Precautions For Indoor Product 1. Water and Moisture - Do not use this unit near water - for example, in a wet basement, in anunprotected outdoor installation or in any areaclassified as a wet location. 2. Objec...
Page 4 - Sécurité; FCC & ICES INFORMATION; This device may not cause harmful interference, and
EN | 4 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | FCC & ICES Information Sécurité Attention : l'installation doit exclusivement être réalisée par dupersonnel qualifié, conformément au code national d'électricitéaméricain (NEC) ou au code d'électricité local en vig...
Page 5 - Veiligheidsmaatregelen
EN | 5 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Safety Precautions Veiligheidsmaatregelen Attentie: het apparaat mag alleen door gekwalificeerd personeelworden geïnstalleerd. De installatie dient in overeenstemmingmet de nationale elektrische richtlijnen of de van t...
Page 6 - Table of Contents
EN | 6 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Table of Contents Table of Contents Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FCC & ICES Infor...
Page 7 - UNPACKING; Parts List; SERVICE; Service Centers; DESCRIPTION; Compatibility Information; communicating; Qty
EN | 7 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Unpacking 1.0 UNPACKING This equipment should be unpacked and handled withcare. If an item appears to have been damaged inshipment, notify the shipper. Verify that all parts shown in the Parts List have been included. ...
Page 8 - Series Cameras manufactured; INSTALLATION; Enclosure Mounting and Location; Section; Connections to AC Power; termnation. The unit accepts; Interface Unit; Figure 1 Typical Video Connections to Interface Unit
EN | 8 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Installation • Any Dinion XF Series Cameras manufactured after April 2004. • Any controller device generating Allegiantbiphase P/T/Z control code protocol. 4.0 INSTALLATION The Allegiant Bilinx Data Interface Unit shou...
Page 9 - Switch Setting Use; Figure 2 Interface Unit Used with Other Video
EN | 9 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Installation NOTE: The video signal and Bilinx controldata require unobstructed two-waycommunication. Do not place active video devices in the coax line, because it will blockthe control data signals. Passive devices, ...
Page 12 - Video Connections to; termination. Unless a; Series Digital Video; LTC 8200 Allegiant Series Switcher; Controller Type; DVR Series
EN | 12 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Installation 4.5 Video Connections to the Controller Unit Video connections from the Interface Unit vary basedon the type of video connections available on thecontroller, and the distance between the controllerand the...
Page 13 - physical
EN | 13 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Installation 1 m (3 ft)LTC 8508/01 Ribbon-to-BNC Cable (Purchased Separately) PC INPUTS 15 16 13 14 11 12 9 10 8 6 5 3 4 2 LOOPING VIDEO 1-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1 RS-...
Page 14 - Allegiant Series Switcher Data; Allegiant Interface Configurations; Supported Ports; IntuiKey; Typical Allegiant; Allegiant Data; Figure 6 Allegiant On-screen Setup Procedure for
EN | 14 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Installation 4.6 Allegiant Series Switcher Data Interface 4.6.1 Allegiant Interface Configurations When using the Allegiant data interface protocol, upto 31 Interface Units can be connected to a singlelarge Allegiant ...
Page 15 - Data Connection to a Biphase
EN | 15 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Installation 4.6.2 Allegiant Data Connections Using a Single Interface Unit Use the supplied 3 m (10 ft) data interface cable toconnect the Allegiant to the Interface Unit. Connectone end of the cable to the Allegiant...
Page 16 - Figure 10 Biphase Data Interface Connection Detail; Figure 11 Biphase RS-232 Data Interface Connection Detail; Data Connections Using Biphase
EN | 16 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Installation LTC 8016 Interface Unit PC INPUTS 15 16 13 14 11 12 9 10 8 6 5 3 4 2 LOOPING VIDEO 1-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1 RS-232 RS-485 IN RS-485 OUT DATA ETHERNET 10...
Page 17 - Series Digital; DVR to the LTC 8016 Interface; Typical DVR or Other biphase-; Allegiant Bilinx; Figure 12 Typical Interface Unit Connected to DVR Control Unit; TYPICAL CONFIGURATION
EN | 17 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Typical Configuration Diagrams 4.8.1 Connecting to DiBos Digital Video Recorders A RS-232 grade data cable (not supplied) is requiredto connect the DiBos DVR to the LTC 8016 InterfaceUnit. A Bosch Security System’s S1...
Page 19 - Figure 15 Large Allegiant System with Several Interface Units; Allegiant System
EN | 19 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Typical Configuration Diagrams ALLEGIANT Video Matrix BOSCH BOSCH BOSCH Video + Data IntuiKey Keyboard Video System Monitors Large Allegiant Matrix System BOSCH POWER / DATA Allegiant Bilinx Data Interface Interface D...
Page 20 - DEVICE OUTLINE; Figure 18 Rear Panel; Figure 17 Front Panel
EN | 20 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Operation 7.0 DEVICE OUTLINE 8.0 CONNECTOR AND CABLE PINOUTS 8.1 LTC 8016 Connector Pinouts 1 Pins are not numbered; the numbers represent the pin sequence from left to right. 2 Pinouts used on units manufactured befo...
Page 21 - Supplied Serial Data Cable Pinouts; MAINTENANCE; Pin
EN | 21 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Maintenance 8.2 Supplied Serial Data Cable Pinouts 8.3 Miscellaneous Cables (Not supplied) Bosch S1385 or Industry standard Null modem RS-232 Data Cable (Required if connecting the LTC 8016 directly to the COM port on...
Page 22 - TROUBLESHOOTING
EN | 22 LTC 8016/90 | Instruction Manual | Troubleshooting 10.0 TROUBLESHOOTING 11.0 LED INDICATORS The Allegiant Bilinx Data Interface Unit incorporatesseveral LEDs that indicate various status conditions.These LEDs are helpful when troubleshooting aproblem. 12.0 REPLACEMENT PARTS Description Part ...
Page 23 - APPENDIX A - Group ID Settings for Large Systems
EN | 23 Bosch Security Systems | 18 August 2005 LTC 8016/90 | Instruction Manual | Appendix A 065 1025 to 1040 066 1041 to 1056 067 1057 to 1072 068 1073 to 1088 069 1089 to 1104 070 1105 to 1120 071 1121 to 1136 072 1137 to 1152 073 1153 to 1168 074 1169 to 1184 075 1185 to 1200 076 1201 to 1216 07...