Bosch Security Systems | 08 May 2013 LTC 5136 Series | Instruction Manual | Important Safeguards EN | 2 Important Safeguards 1. Read Instructions - All safety and operating instructions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should ...
Page 3 - LTC 5136 Series | Instruction Manual | FCC Information; FCC & ICES Information; THIS IS A CLASS A PRODUCT. IN A DOM ESTIC
Bosch Security Systems | 08 May 2013 LTC 5136 Series | Instruction Manual | FCC Information EN | 3 17. Damage Requiring Service - Unplug the unit from the outlet and refer servicing to qualified service personnel under the following conditions: a. When the power supply cord or plug is damaged. b. If...
Page 4 - LTC 5136 Series | Instruction Manual | Safety Precautions; Safety Precautions; CAUTION: TO REDUCE THE RISK OF
Bosch Security Systems | 08 May 2013 LTC 5136 Series | Instruction Manual | Safety Precautions EN | 4 Safety Precautions CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash...
Page 5 - LTC 5136 Series | Instruction Manual | Contents; Table of Contents
Bosch Security Systems | 08 May 2013 LTC 5136 Series | Instruction Manual | Contents EN | 5 Table of Contents Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FCC Information . . . . . . . . . . ...
Page 6 - LTC 5136 Series | Instruction Manual | Unpacking; UNPACKING; Check for the following items:; SERVICE; daisy chain; Service Centers
Bosch Security Systems | 08 May 2013 LTC 5136 Series | Instruction Manual | Unpacking EN | 6 1 UNPACKING This electronic equipment should be unpacked and handled carefully. Check for the following items: • LTC 5136/61 or LTC 5136/51 Desktop Controller. • Interface unit. • Power supply. • Power suppl...
Page 7 - LTC 5136 Series | Instruction Manual | Installation; INSTALLATION; Installation Using Biphase Code
Bosch Security Systems | 08 May 2013 EN | 7 LTC 5136 Series | Instruction Manual | Installation 4 INSTALLATION 4.1 General The desktop Controller unit should be installed in a location convenient to the operator. The Controller contains a single RJ-11 connector, which is used for both power and data...
Page 8 - Direct to Camera Site; Figure 2 Junction Box Supplied with
Bosch Security Systems | 08 May 2013 EN | 8 LTC 5136 Series | Instruction Manual | Installation polarity sensitive. Plug the power supply into a suitable AC power source. Connect the supplied 3 m (10 ft) data cable with two RJ-11 connectors, between the Controller unit and the junction box. The orie...
Page 9 - Installation Using an RS-232 Data; Data
Bosch Security Systems | 08 May 2013 EN | 9 LTC 5136 Series | Instruction Manual | Installation 4.4 Installation Using an RS-232 Data Transmission Link to a Biphase Camera Site (See Figure 6) In this application, the RS-232 data that is generated by the Controller is connected directly to an RS-232 ...
Page 10 - LTC 5136 Series | Instruction Manual | Setting Fast Address; AutoDome Camera or; Figure FA1
Bosch Security Systems | 08 May 2013 LTC 5136 Series | Instruction Manual | Setting Fast Address EN | 10 4.5 AutoDome Camera or Receiver/Driver Site Configuration Follow the standard installation instructions provided with the AutoDome Camera or Allegiant Series Receiver/Driver unit to connect the d...
Page 11 - CONTROLLER OPERATION; peed
Bosch Security Systems | 08 May 2013 EN | 11 LTC 5136 Series | Instruction Manual | Controller Operation 5. Press ON-1-ENTER and the address is set. Once the Fast Address is set, the switch address (thumbwheel) is ignored. The Fast Address is stored to non-volatile memory, and will not change if pow...
Page 13 - LTC 5136 Series | Instruction Manual | Technical Reference; TECHNICAL REFERENCE; Figure 3 Typical Camera Site Using Biphase Control Code; Controller
Bosch Security Systems | 08 May 2013 EN | 13 LTC 5136 Series | Instruction Manual | Technical Reference 7 TECHNICAL REFERENCE Video Monitor Power Supply Adapter Video Signal Video Signal DVR or Video Switcher Data Converter Unit Up to 16 biphase control code outputs RS-232 Data & Power Typical A...
Page 14 - Communication Link
Bosch Security Systems | 08 May 2013 EN | 14 LTC 5136 Series | Instruction Manual | Technical Reference Video Monitor Video Signal Power Supply Adapter Controller RS-232 Data & Power LTC 8557 Junction Box RS-232 Cable or Communication Link Typical AutoDome Camera or Allegiant Receiver/Driver uni...
Page 15 - Pin 6; Figure 8 Rear Panel Controller Connector Detail; Figure 9 Mounting Dimensions of Supplied Interface Box
Bosch Security Systems | 08 May 2013 EN | 15 LTC 5136 Series | Instruction Manual | Technical Reference Pin 6 Pin 1 Pin 1 Pin 6 Figure 7 Supplied 6- Conductor 3 m (10 ft) Data Cable Detail Connector Pinouts: 1. 12V 2. Not used 3. Rx (Not used) 4. Tx 5. Signal Ground 6. 12V Pin 6 Pin 1 Figure 8 Rear ...
Page 16 - LTC 5136 Series | Instruction Manual | Data Converter Pinouts; DATA CONVERTER PINOUTS
Bosch Security Systems | 08 May 2013 LTC 5136 Series | Instruction Manual | Data Converter Pinouts 8 DATA CONVERTER PINOUTS Data In - 9-Pin Connector (Male) Pin Connection 1 No Connection 2 Rx 3 No Connection 4 No Connection 5 Ground 6 No Connection 7 No Connection 8 No Connection 9 No Connection KB...