Page 3 - Table of Contents
Global View Station 1000 Table of Contents | en 3 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 Table of Contents 1 Safety 5 1.1 Important safety instructions 5 1.2 Safety precautions 7 1.3 Important notices 7 1.4 Customer Support and Service 11 2 Standard Operations 1...
Page 5 - Safety; Important safety instructions; sufficient magnitude to constitute a risk of shock.
Global View Station 1000 Safety | en 5 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 1 Safety 1.1 Important safety instructions DANGER! The Lightening Flash with arrowhead symbol within an equilateral triangle indicates the presence of uninsulated dangerous voltages wi...
Page 7 - Safety precautions; Electronic Surveillance -
Global View Station 1000 Safety | en 7 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 1.2 Safety precautions 1.3 Important notices All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at least 3 mm in each pole, into the electrical ...
Page 8 - Grounding and polarization -
8 en | Safety Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid electrostatic discharge. NOTE: Wear required grounded wrist straps and observe proper ESD safety ...
Page 9 - FCC Rules
Global View Station 1000 Safety | en 9 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To m...
Page 10 - . Cette brochure est; Copyright; trademarks and must be treated accordingly.; More information
10 en | Safety Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. Toute modification apportée au produit, non expressément approuvée par la partie responsable de l'appareil, est strictement interdite. Une telle modification est susceptible d'entraîn...
Page 11 - Customer Support and Service; authorization to return and shipping instructions.
Global View Station 1000 Safety | en 11 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 1.4 Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service C...
Page 12 - Standard Operations; Zoom and Focus Control
12 en | Standard Operations Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 2 Standard Operations 2.1 Pan/Tilt Standard pan and tilt operations are available - left, right, up, and down. The system is capable of variable speeds, and features hard...
Page 13 - Soft Limits
Global View Station 1000 Standard Operations | en 13 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 2.4 Soft Limits The soft limits are used to set programmed limits on the pan and tilt range. To adjust the soft limits, perform the following steps: – Program preset 34. ...
Page 14 - Auxiliary Functions
14 en | Standard Operations Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. – To program Tour 2 follow this command sequence: – Program Preset 82(Enter programming mode) – Call Preset 01 (Position 1 of the camera) – Call Preset 04 (Dwell time at ...
Page 15 - Aux 3: Illuminator Control
Global View Station 1000 Standard Operations | en 15 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 Aux 3: Illuminator Control Aux3 ON or Call preset 53 : photocell control mode Aux3 OFF or Call preset 54 : manual control mode Default: manual control mode When in photoc...
Page 17 - Code Translator Unit; Pelco Support; The Pelco code translator box has four (4) status LEDs as shown below:
Global View Station 1000 Code Translator Unit | en 17 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 3 Code Translator Unit The code translator unit, with the auxiliary and camera control boards act as receivers for the GVS1000 unit. During operation, LED indicators on ...
Page 18 - Biphase Support; translator has four status LEDs, but only two are operational.
18 en | Code Translator Unit Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 3.2 Biphase Support A unit with Biphase support is installed with two code translator units, as shown in Figure 3.2 , the Pelco P/D code translator and the Biphase trans...
Page 19 - Camera Default Configuration; Left Key
Global View Station 1000 Camera Default Configuration | en 19 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 4 Camera Default Configuration The camera is factory set for optimum performance. The following is for reference. For complete information on the cameras setting...
Page 21 - Installer Menu; Lens Type
Global View Station 1000 Camera Default Configuration | en 21 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 Installer Menu The table below shows the Installer Menu default camera settings for the camera. Submenu Function Value Lens Wizard Lens Type Video Alarm I/O Alar...
Page 22 - Troubleshooting; General; Section 5.2 Troubleshooting with Diagnostic Mode, page 23
22 en | Troubleshooting Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 5 Troubleshooting 5.1 General Symptom Possible Solution No Pan/Tilt movement when using a keyboard to control the unit Check that the main power is on. Main power is on when ...
Page 23 - Troubleshooting with Diagnostic Mode
Global View Station 1000 Troubleshooting | en 23 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 5.2 Troubleshooting with Diagnostic Mode In the auxiliary control board, change DIP1, Switch 6 to ON. The GVS1000 diagnostics mode is now active. The GVS1000 will cycle throu...
Page 24 - Test Software; PTCR-20 Software Operation; Install the PTCR-20 Remote Emulator using the supplied CD.
24 en | Test Software Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 6 Test Software A test program, PTCR-20, is provided for system maintenance. It is strongly advised that this program is used only when necessary. The user can validate operati...
Page 25 - Using the PTCR-20 Software; from computer to computer.; and the PC has been established.
Global View Station 1000 Test Software | en 25 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 Using the PTCR-20 Software 1. Run PTCR-20. The PC shows the display below. Figure 6.2 PTCR-20 Main Screen 2. Verify COM port and Baud rate (9600 bps), and then click START. The...
Page 26 - Default Parameters; Click the CAMERA button. The default parameters are as shown below.; Using PTCR-20 to Set Soft Limits and Camera Control; Disengage the SL Override before exiting the software.
26 en | Test Software Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 6.1.1 Default Parameters 1. Click the SETUP button. The default setup parameters are as shown below. Figure 6.5 Default Setup Set tings 2. Click the CAMERA button. The default ...
Page 27 - circle will be green.
Global View Station 1000 Test Software | en 27 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 Figure 6.7 PTCR-20 Soft Limit Configuration The colored circles on the right side of the software screen show a yellow or red color if a positional soft limit or hard limit has...
Page 28 - Inverting Tilt Controls; Other Menus
28 en | Test Software Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 6.1.3 Inverting Tilt Controls To invert the tilt settings, change the tilt settings: – Uncheck Tilt Mtr Reverse – Uncheck Tilt Res Invert – Click Set Normal/Reverse – Click Get...
Page 29 - Component Description
Global View Station 1000 Test Software | en 29 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 6.2 Auxiliary Control Board Figure 6.11 Auxiliary Control Board Component Description SW1 Board reset button JP6 T1 telemetry jumper JP7 T2 telemetry jumper T1 RS485/422 teleme...
Page 31 - Auxiliary Controls
Global View Station 1000 Test Software | en 31 Bosch Security Systems, Inc. Operations Manual F.01U.173.867 | 2.0 | 2010.11 6.3 Auxiliary Controls 6.3.1 Aux 1 2x Doubler Function – LED1 – doubler function indicator – LED1 ON = doubler on – LED1 OFF = doubler off – Default: OFF 6.3.2 Aux 2 Wiper Func...
Page 32 - Voltage Touch Points; T3 SLED Power Input Indicator
32 en | Test Software Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 6.4 Voltage Touch Points 6.4.1 T3 SLED Power Input Indicator – LED11 – indicates SLED controller power (not actual on/off state of illuminators) – LED11 ON = SLED controller po...
Page 34 - GSV1000 Installation Manual
34 en | Test Software Global View Station 1000 F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc. 6.5.1 Reset Button – SW1 – resets the board to default settings – Resetting should be used when changing the system address or communication protocol when the unit is powered. ...