Page 3 - Table of Contents; Safety
ATM/POS Bridge Table of Contents | en 3 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 Table of Contents 1 Safety 5 1.1 FCC & ICES compliance 7 2 Description 9 2.1 Parts List 9 2.2 Supported Protocols 9 3 System Overview 10 4 Installation 11 4.1 Mounting the Bridg...
Page 4 - Configuration Using HyperTerminal
4 en | Table of Contents ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 6 Configuration Using HyperTerminal 24 6.1 Connecting the Bridge 24 6.2 Initiating a HyperTerminal Session 24 6.3 Configuring Bridge Operation via HyperTerminal 26 6.3.1 Network Set...
Page 7 - FCC & ICES compliance; FCC & ICES Information; FCC Rules; residential; How to Identify
ATM/POS Bridge Safety | en 7 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 1.1 FCC & ICES compliance FCC & ICES Information (U.S.A. and Canadian Models Only) This equipment has been tested and found to comply with the limits for a Class B digital device, purs...
Page 8 - Informations FCC et ICES; section 15 du règlement; installation résidentielle; How to Identify and
8 en | Safety ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. Informations FCC et ICES (modèles utilisés aux États-Unis et au Canada uniquement) Suite à différents tests, cet appareil s'est révélé conforme aux exigences imposées aux appareils numériques ...
Page 9 - Description; Parts List
ATM/POS Bridge Description | en 9 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 2 Description The ATM/POS Bridge provides an interface between a digital recorder and either Automatic Teller Machines (ATM) or Point- of-Sale (POS) equipment such as cash registers. Both...
Page 10 - System Overview
10 en | System Over view ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 3 System Overview The following illustration shows an example of how a bridge is used in a network of digital video recorders and POS terminals. Figure 3.1 POS terminal network The ...
Page 11 - Installation; This section details the physical installation of the ATM/POS; Mounting the Bridge; Determine a location where all incoming connections can reach
ATM/POS Bridge Installation | en 11 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 4 Installation This section details the physical installation of the ATM/POS Bridge. 4.1 Mounting the Bridge Determine a location where all incoming connections can reach the ATM/POS Br...
Page 12 - Making Connections to the Bridge; Use the following illustration to make the appropriate; Ethernet RJ45 connector
12 en | Installation ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 4.2 Making Connections to the Bridge Use the following illustration to make the appropriate connections to the ATM/POS Bridge: Figure 4.1 ATM/POS Bridge connectors 1 Ethernet RJ45 conne...
Page 13 - Connector Detail, page 14
ATM/POS Bridge Installation | en 13 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 1. Connect the supplied DC power adapter unit to the DC power input connector of the bridge. 2. Connect the RJ45 connector of the bridge via a straight Ethernet CAT5 network cable to a ...
Page 14 - COM Connector Detail; Pin
14 en | Installation ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 4.3 COM Connector Detail The four COM connectors on the bridge are all 9-pin SubD-type male connectors. Figure 4.2 COM connector detail Note: The console cable has pin 9 connected to pi...
Page 15 - Configuration; Section 6 Configuration Using HyperTerminal, page 24; Using the Bridge Detector Utility
ATM/POS Bridge Configuration | en 15 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 5 Configuration You must configure the ATM/POS Bridge network settings to ensure proper communication on an existing TCP/IP network. This section provides configuration details using t...
Page 16 - Using the Direct Connection
16 en | Configuration ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 3. From a PC connected to the same network, launch the BridgeDetector.exe application, located on the CD. The PC opens the Bridge Detector window that displays the MAC Address and the ...
Page 18 - Configuring Operation via a Network; System Menu
18 en | Configuration ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 5.2 Configuring Operation via a Network After the bridge is properly configured for network access, you can configure the COM and Terminal settings via Internet Explorer. To access the...
Page 19 - Network Setup
ATM/POS Bridge Configuration | en 19 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 – Simulation Mode : Select the type of device to test the connection between the bridge and the digital recorder. Select this mode to send sample data from the bridge to the digital re...
Page 21 - Terminal; Name
ATM/POS Bridge Configuration | en 21 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 5.2.3 Terminal The Terminal Setup pages allow you to configure the bridge to accept transactions from the ATM/POS devices connected to the bridge. – Name : Type an optional name for th...
Page 22 - Code Page
22 en | Configuration ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. – Code Page : Select the code page (character set for a particular language) that the ATM/POS terminal uses to encode transaction data. The selections are: – PC437 (Latin 1) – PC858 (L...
Page 23 - COM Port; Comport Mode
ATM/POS Bridge Configuration | en 23 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 5.2.4 COM Port The COM Port page enables you to configure the four physical communication port settings on the bridge. – Comport Mode : Select the appropriate communication method betw...
Page 24 - Section A Updating Bridge Firmware, page 36; Connecting the Bridge
24 en | Configuration Using HyperTerminal ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 6 Configuration Using HyperTerminal You can configure the ATM/POS Bridge via a PC HyperTerminal session. The PC is connected to the COM 3 (console) port on the brid...
Page 25 - Section 6.3 Configuring Bridge Operation via
ATM/POS Bridge Configuration Using HyperTerminal | en 25 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 4. Ensure that the settings in the COM Properties dialog box match these settings: – Bits per second: 9600 – Data bits: 0 – Parity: None – Stop bits: 1 – Flow contr...
Page 28 - Communication Channels
28 en | Configuration Using HyperTerminal ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 6.3.2 Communication Channels Select the Communication Channel option to configure the four physical communication port settings on the bridge. Select the appropriat...
Page 29 - Terminal Setup
ATM/POS Bridge Configuration Using HyperTerminal | en 29 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 6.3.3 Terminal Setup The Terminal Setup pages allow you to configure the bridge to accept transactions from the devices connected to the bridge. Select a terminal n...
Page 31 - Simulation Mode
ATM/POS Bridge Configuration Using HyperTerminal | en 31 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 6.3.4 Simulation Mode Use the Simulation Mode to select the type of device to test the connection between the bridge and the digital recorder. Select this mode to s...
Page 32 - Service Menu; Restore Defaults
32 en | Configuration Using HyperTerminal ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 6.3.6 Service Menu The System Menu contains settings for bridge operation. – Restore Defaults : Resets all COM and Terminal settings to factory defaults. This butto...
Page 33 - Troubleshooting
ATM/POS Bridge Troubleshooting | en 33 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 7 Troubleshooting If you are unable to capture transaction data, follow these steps: 1. Check all cable connections. 2. Check the TCP/IP network connection with the ATM/POS Bridge. E...
Page 34 - Technical Data; Electrical
34 en | Technical Data ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. 8 Technical Data Electrical Power Supply External DC power supply (supplied) Input: 100–240 VAC, 150 mA, 50/60 Hz Output: 12 VDC, 450 mA Connector DC jack, positive center pin, 10–30 ...
Page 35 - EMC
ATM/POS Bridge Technical Data | en 35 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 EMC Requirements USA: FCC Part 15, Class B EU: EMC directive 89/336/EEC Immunity: EN50130-4 Emission: EN55022 Class B Harmonics: EN61000-3-2 Voltage Fluctuations: EN61000-3-3 Safety U...
Page 36 - Updating Bridge Firmware
36 en | ATM/POS Bridge F.01U.171.816 | 1.0 | 2010.09 Installation Manual Bosch Security Systems, Inc. A Updating Bridge Firmware Follow the steps below to update the firmware on the ATM/ POS Bridge. 1. Download the Zip file for the ATM/POS Bridge firmware from the Bosch Security Systems Web site (ww...
Page 41 - Troubleshooting Bridge Firmware Update
ATM/POS Bridge | en 41 Bosch Security Systems, Inc. Installation Manual F.01U.171.816 | 1.0 | 2010.09 Troubleshooting Bridge Firmware Update Use the following steps to correct the firmware settings If you receive the following error during the firmware update process: 1. Click OK to acknowledge the ...