Page 2 - Copyright Notice; Bosch; Notice of Liability; not
CC408 | Operators Guide | Notices EN | 2 Bosch Security Systems | 5/04 | 920050O.OG.112 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd (“ Bosch ”). All rights are reserved. You may download a single copy of this publication. By downlo...
Page 3 - Contents; Figures
CC408 | Operators Guide | Contents EN | 3 Bosch Security Systems | 5/04 | 920050O.OG.112 Contents 1. Introduction ...................................................... 5 2. Specifications .................................................... 5 3. Features ...............................................
Page 4 - Tables
CC408 | Operators Guide | Contents EN | 4 Bosch Security Systems | 5/04 | 920050O.OG.112 Tables Table 1: Specifications ............................................. 5 Table 2: Zone Indicator ........................................... 6 Table 3: AWAY Indicator .........................................
Page 5 - EN; Introduction; Specifications; Section 17 Testing; Features
CC408 | Operators Guide | 1. Introduction EN | 5 Bosch Security Systems | 5/04 | 920050O.OG.112 1. Introduction Congratulations on selecting the Solution 880 Model CC408 Control Panel to protect you and your property. To obtain the most from your unit, take the time to read through this manual and f...
Page 6 - Operators Guide | 4. Codepad Indicators; Codepad Indicators; Indicators; Disarmed
CC408 | Operators Guide | 4. Codepad Indicators EN | 6 Bosch Security Systems | 5/04 | 920050O.OG.112 4. Codepad Indicators Figure 1: CP5 Eight Zone LED Codepad Figure 2: CP5 Eight Zone LCD Codepad The codepad is the communications interface between you and your alarm system. Use the codepad to issu...
Page 7 - MAINS Indicator; Off Indicator/Zone Sealed; Section 12. Fault Analysis Mode; Indications; Table 7; Arming the System; Table 8
CC408 | Operators Guide | 5. Arming the System EN | 7 Bosch Security Systems | 5/04 | 920050O.OG.112 4.5 MAINS Indicator The MAINS indicator displays the systems AC mains supply is normal or failed. Table 5: MAINS Indicator MAINS Indicator Definition On AC mains power normal. Flashing AC mains suppl...
Page 8 - Section 6. Disarming; Arming in STAY Mode 1
CC408 | Operators Guide | 5. Arming the System EN | 8 Bosch Security Systems | 5/04 | 920050O.OG.112 Forced Arming The feature of arming the system when a zone is not sealed is known as forced arming. If the system does not arm and a long beep is heard, forced arming is not permitted. If this is the...
Page 9 - Operators Guide | 6. Disarming the System; Programming STAY Mode 2 Zones; Enter the zone number to be automatically; Disarming the System; Adding User Codes; Enter the digits required for the new code; Adding Radio Remote User Codes; Enter the radio remote user code number (9 to
CC408 | Operators Guide | 6. Disarming the System EN | 9 Bosch Security Systems | 5/04 | 920050O.OG.112 Arming in STAY Mode 2 Hold down the [0] button until two beeps sound. The STAY indicator lights and exit time starts counting. Any zones programmed to be automatically isolated in STAY Mode 2 flas...
Page 10 - Alarms; Alarm
CC408 | Operators Guide | 8. Radio Transmitter Operations EN | 10 Bosch Security Systems | 5/04 | 920050O.OG.112 8. Radio Transmitter Operations Figure 3: RE012/E – 2 Channel Keyfob Transmitter 1 2 3 1 – Button 1: Arm or disarm in AWAY Mode 2 – Button 2: Arm or disarm STAY Mode 3 – Buttons 1 and 2: ...
Page 11 - Isolating Zones; Isolating; How to Isolate a Zone; Code to Isolate; Section 10.1 Standard Isolating; Setting the Date and Time; How to Program Date and Time
CC408 | Operators Guide | 10. Isolating Zones EN | 11 Bosch Security Systems | 5/04 | 920050O.OG.112 9.3 Fire Alarm The horn speaker emits a distinct fire sound when both the [4] and [6] keys are pressed simultaneously. Contact your installer to disable the ability to activate the codepad fire alarm...
Page 12 - Operators Guide | 12. Fault Analysis Mode; Fault Analysis Mode; Fail; for the list of; Descriptions; Section 11. Setting the Date
CC408 | Operators Guide | 12. Fault Analysis Mode EN | 12 Bosch Security Systems | 5/04 | 920050O.OG.112 12. Fault Analysis Mode If a fault occurs, the FAULT or MAINS indicators flash and the codepad beeps once every minute. 12.1 AC Fail If the AC mains supply fails, the MAINS indicator flashes unti...
Page 13 - Telco Arm Sequence; Telco Disarm Sequence; Enter your four-character Master Code followed
CC408 | Operators Guide | 13. Telco Arm/Disarm Sequence (Call Forward On/Off) EN | 13 Bosch Security Systems | 5/04 | 920050O.OG.112 13. Telco Arm/Disarm Sequence (Call Forward On/Off) Use this feature to program the Telco Arm Sequence and Telco Disarm Sequence (Call Forward On/Off). 13.1 Telco Arm ...
Page 14 - Reset Latching Outputs; How To Reset Latching Outputs; Change; Horn Speaker Test
CC408 | Operators Guide | 14. Turning Outputs On/Off EN | 14 Bosch Security Systems | 5/04 | 920050O.OG.112 14. Turning Outputs On/Off This feature only applies if your installer set up an output that can be turned on or off by the codepad. The output programmed by your installer can control a pool ...
Page 15 - Event Memory Recall; How to Enter Event Memory; Remote Arming By; Call the telephone number connected to your
CC408 | Operators Guide | 18. Event Memory Recall EN | 15 Bosch Security Systems | 5/04 | 920050O.OG.112 18. Event Memory Recall Use this function to replay the last 40 events that occurred to the system. The event memory history replays all alarms and arming/disarming of the system in AWAY Mode, ST...
Page 16 - Domestic Dialling; Acknowledging Domestic Calls; Table 12: Domestic Dialling Telephone Digits; Programming Domestic Telephone; How to Program Telephone Numbers; Disable Domestic Dialling
CC408 | Operators Guide | 21. Domestic Dialling EN | 16 Bosch Security Systems | 5/04 | 920050O.OG.112 21. Domestic Dialling Domestic dialling is used to call your mobile phone or a relative/friend in the event your control panel activates an alarm. Up to three different telephone numbers can be pro...
Page 18 - Operators Guide | 23. Basic Pager Reporting; Basic Pager Reporting; describes what each number; Figure 7
CC408 | Operators Guide | 23. Basic Pager Reporting EN | 18 Bosch Security Systems | 5/04 | 920050O.OG.112 23. Basic Pager Reporting This feature only applies if your system reports to a pocket pager. Basic pager reporting requires some interpretation of the numbers that appear on the display. It is...
Page 20 - Glossary of Terms; Table 15: Glossary of Terms
CC408 | Operators Guide | 24. Glossary of Terms EN | 20 Bosch Security Systems | 5/04 | 920050O.OG.112 24. Glossary of Terms Table 15: Glossary of Terms Term Description 24-Hour Zones A monitored input programmed to trigger an alarm condition when violated when the system is armed or disarmed 24 hou...
Page 22 - Installation Notes; Service Notes
CC408 | Operators Guide | 25. Installation Notes EN | 22 Bosch Security Systems | 5/04 | 920050O.OG.112 25. Installation Notes Company Name Technician’s Name Technician’s Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes
Page 23 - Operators Guide | 25. Installation Notes; Zone Description
CC408 | Operators Guide | 25. Installation Notes EN | 23 Bosch Security Systems | 5/04 | 920050O.OG.112 Zone Description Describe each zone and mark the zones that are programmed to be automatically isolated in STAY Mode 1 or are programmed for day alarm operation. Isolated In STAY Mode 1 Day Alarm ...
Page 24 - Arming Options
CC408 | Operators Guide | 25. Installation Notes EN | 24 Bosch Security Systems | 5/04 | 920050O.OG.112 Entry/Exit Times Entry Timer 1 Exit Time Entry Timer 2 Entry Guard Time Arming Options Single Button Arming YES NO Forced Arming YES NO Single Button Disarming YES NO Remote Arming By Telephone YE...
Page 25 - Index
CC408 | Operators Guide | Index EN | 25 Bosch Security Systems | 5/04 | 920050O.OG.112 Index 24-Hour Zones 20 A AC Mains Fail 12 Adding Radio User Codes 9 Adding User Codes 9 Alarm Condition 20 Alarms Duress .................................................................... 10 Fire ..................