Page 2 - CAUTION; RISK OF ELECTRIC SHOCK

Notice Every effort was made to ensure that the information in this manualwas complete and accurate at the time of printing. However, infor-mation is subject to change. FCC Statement (Part 1 5) - Radio Frequency Interference This unit generates and uses radio frequency energy and if not in-stalled a...

Page 3 - Theory of Operation

Loop Start Interfacing: The TAMB2 provides a 24V DC talk battery on its T (tip) andR (ring) terminals. When it detects a DC loop current flowthrough these terminals, it will activate. Upon activation, it willproduce an announcement tone and connect in the pagingamplifier through an isolation transfo...

Page 4 - 00-ohm Balanced Input; Hi-Z Unbalanced Input; Balanced Input Wiring:; IMPORTANT; Keep Amp turned off until all; PBX Ground Start Trunk; PBX Loop Start Trunk Port

Connections to Paging Amplifier Input Connections to Telephone Equipment STATION/ TRUNK PAGE OUT PT PR G/S T R 600-ohm Balanced Input STATION/ TRUNK PAGE OUT PT PR G/S T R Hi-Z Unbalanced Input Impedance-Matching Transformer WMT1A Balanced Input Wiring: The TAMB2 was designed to connect to a 600-ohm...