Page 2 - Contents; Description; APPENDIX; Module Assembly
Zone #’s S 1 S2 S3 S4 Master 1 -9 0 0 0 0 Satellite 1 1 0- 1 8 1 0 0 0 2 1 9-27 0 1 0 0 3 28-36 1 1 0 0 4 37-45 0 0 1 0 5 46-54 1 0 1 0 6 55-63 0 1 1 0 7 64-72 1 1 1 0 8 73-8 1 0 0 0 1 9 82-90 1 0 0 1 1 0 9 1 -99 0 1 0 1 Contents SECTION I - APPLICATON CONFIGURATIONS ...................................
Page 3 - BOGEN; PBX; BOGEN P; SECTION I: APPLICATION CONFIGURATIONS; SETUP FOR CONFIGURATION
Time Trigger 6 Zone Group *86 Zone Numbers No Zones Inhibit 1 60 Inhibit Enable 1 6 1 HHMM (See Note 3 - below) 2-Second Tone 1 62 3-Second Tone 1 63 3-Second Tone 4-Second Tone 1 64 5-Second Tone 1 65 6-Second Tone 1 66 7-Second Tone 1 67 8-Second Tone 1 68 Chime 1 69 Time Trigger 7 Zone Group *87 ...
Page 6 - SECTION II - PROGRAMMING
SECTION II - PROGRAMMING SYSTEM PROGRAMMING System programming lets you set certain PCM options and tone features using the DTMF keys of a telephone. It also lets you program pag-ing zone groups and signaling zone groups.All programming is accomplished through the TEL LINE jack on the PCMTIM module ...
Page 7 - CONFIGURATION
Each PCMZPM module has three relay driver outputs - RD A, RD B, and RD C - one for each speaker zone.When a zone is activated, its relay driver is shorted to RD COM through an open collector transistor. These drivers can be used to activateexternal relays to provide greater power capacity or to oper...
Page 8 - Music Source
CONFIGURATION 3: LOOP START TRUNK - 3-ZONE - ONE-WAY PAGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk battery and loop current detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the loop start trunk in the telephone system...
Page 10 - SHURE
CONFIGURATION 4: GROUND START TRUNK - 3-ZONE - ONE-WAY PAGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit supplies a 48V talk battery and loop current detection from pins 3 & 4 of the TEL LINE jack on the PCMTIM module to the ground start trunk in the telephone sy...
Page 12 - PR
CONFIGURATION 5: STATION LEVEL/CENTREX - 3-ZONE - ONE-WAY PAGING - SINGLE AMPLIFIER - 25/70V AC SPEAKERS In this configuration, the PCM unit responds to a 90V AC 20Hz ringing signal in pins 3 & 4 of the TEL LINE jack on the PCMTIM module andanswers after the first full ring. As soon as it answer...
Page 13 - SA; SETUP FOR CONFIGURATION 6: EXTENDED PAGING SYSTEM
CONFIGURATION 1 2: DFT 1 20 & TAMB WIRING DIAGRAM - LOOP START TRUNK, GROUND START TRUNK, OR STATION LEVEL In this configuration, the telephone output is connected to the Bogen Telephone Access Module model TAMB; the TAMB module is connectedto the Bogen Digital Feedback Terminator model DFT 1 20...
Page 14 - AM B
CONFIGURATION 6: EXTENDED PAGING SYSTEM This illustration shows the wiring between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging. As described previously, the required setup for one-way basic configuration includes: PCMTIM, PCMCPU, PCMZPM, an...