Page 2 - TABLE OF CONTENTS
TABLE OF CONTENTS Table of Contents ................................................................................................................................... 2 Safety Instructions .................................................................................................................
Page 3 - IMPORTANT!—PLEASE READ AND FOLLOW
IMPORTANT!—PLEASE READ AND FOLLOW 1. THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION AND OPERATION. HOWEVER, WE RECOMMEND THAT YOU READ ALL SECTIONS OF THIS MANUAL BEFORE YOU BEGIN INSTALLA-TION. 2. DO NOT REMOVE PERMANANTLY AFFIXED LABELS, WARNINGS OR DATA PLATES FROM YOUR APPLIANCE. THIS MAY ...
Page 5 - The staff and team at Prizer Stove Works !
Since 1880, we have been dedicated to quality! We believe that our success can only be measured by the continuing success of our customers. We achieve customer satisfaction by ensuring that each of our employees understands, meets and exceeds customer expectations. We establish and maintain an envir...
Page 7 - HANDLING; REMOVE HOOD FROM ORIGINAL CARTON UNTIL YOU ARE READY TO IN-; UNPACKING
HANDLING REMOVE ALL WATCHES, BELT BUCKLES, JEWELRY, RINGS AND ANY CLOTHING WITH METAL BUTTONS OR SNAPS TO PREVENT DAMAGE TO THE HOOD. WHEN YOU BEGIN THE INSTALLATION PROCESS REMOVE THE HOOD FROM IT’S ORIGI-NAL CARTON AND PLACE THE HOOD ON A CLEAN, NON-ABRASIVE BLANKET. INSPECT THE HOOD CARE...
Page 8 - PACKING LIST FOR PRO LINE HOOD SERIES
PACKING LIST FOR PRO LINE HOOD SERIES PL30240——24” depth No blower (Sold and Packaged Separately) Two (2) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram PL36240, PL42240—24” depth No blower (Sold and Packag...
Page 9 - PACKING LIST FOR PYRAMID STYLE HOOD SERIES
PACKING LIST FOR PYRAMID STYLE HOOD SERIES PC30240—24” depth No blower (Sold and Packaged Separately) Two (2) Stainless Steel Baffle Filters Two (2) Pre-Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram Duct cover sold packed in separate box (2 of2) PC...
Page 11 - DIMENSIONS OF THE PRO LINE SERIES HOOD
DIMENSIONS OF THE PRO LINE SERIES HOOD INLET LOCATION FOR THE ELECTRICAL CONNECTION IS LOCATED NEAR THE REAR CENTER OF HOOD 3-3/16” FROM HOOD BOTTOM. ELECTRICAL REQUIREMENTS: 15 AMPS AT 120 VOLTS LIGHT BULBS ARE HALOGEN G9, 120V, 25W BULBS ARE OPERATED BY A DIMMER SWITCH BLOWER IS VAR...
Page 12 - SITE PREPARATION FOR PRO LINE SERIES
IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MOST USERS. IF MOUNTED AT A HEIGHT GREATER T...
Page 13 - THE CORRECT HEIGHT OF YOUR PRO LINE SERIES HOOD
THE CORRECT HEIGHT OF YOUR PRO LINE SERIES HOOD THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72" ABOVE THE FLOOR. THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN 72" ABOVE THE...
Page 14 - PRO LINE DUCT INFORMATION; IMPORTANT PLANNING INFORMATION!
PRO LINE DUCT INFORMATION MODEL BLOWER (cfm) DUCT SIZE TRANSITION BS-PL30240 BS-PLIB600 6” BS-PL30240 BS-PLIB1200 10” BS-PL36240 BS-PLIB600 6” BS-PL36240 BS-PLIB1200 10” TR6X15/10 BS-PL42240 BS-PLIB600 6” BS-PL42240 BS-PLIB1200 10” TR6X15/10 BS-PL48240 BS-PLIB1200 10” TR6X15/10 BS-PL54240 BS-PLIB120...
Page 15 - INSTALLATION OF YOUR PRO LINE SERIES HOOD BLOWER; INSTALLATION OF BS-PLIB600 INTERNAL BLOWER KIT
INSTALLATION OF YOUR PRO LINE SERIES HOOD BLOWER INSTALLATION OF BS-PLIB600 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM 1. REMOVE SHIPPING BRACKET (SEE ITEM 1)FROM HOOD. DO NOT DISCARD SCREWS! 2. INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET. 3. LOCATE THE TERMINAL BLOCK I...
Page 16 - INSTALLATION GUIDE FOR PRO LINE DUCT COVER
INSTALLATION GUIDE FOR PRO LINE DUCT COVER LARGE HOLE FITS OVEREXISTING RIVET IN HOOD REMOVE RIVETS THATLINE UP WITH SMALLHOLES IN DUCT COVER SMALL HOLES USED FOR FASTENING OPTIONAL ATTACHMENT HOLES REMOVE POP RIVETS FROM PRO HOOD THAT CORRESPOND WITH THE SMALL HOLES ON THE DUCT COVER. INSTALL...
Page 17 - DIMENSIONS OF THE PYRAMID STYLE SERIES HOOD
DIMENSIONS OF THE PYRAMID STYLE SERIES HOOD P/N 750306 Page 17
Page 18 - SITE PREPARATION FOR PYRAMID STYLE SERIES
SITE PREPARATION FOR PYRAMID STYLE SERIES IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MO...
Page 19 - THE CORRECT HEIGHT OF YOUR PYRAMID STYLE HOOD
THE CORRECT HEIGHT OF YOUR PYRAMID STYLE HOOD THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72" ABOVE THE FLOOR. THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN 72" ABOVE THE F...
Page 20 - PYRAMID STYLE DUCT INFORMATION; IMPORTANT PLANNING INFORMATION
PYRAMID STYLE DUCT INFORMATION MODEL BLOWER (cfm) DUCT SIZE BS-PC30240 BS-PCIB600 6” BS-PC36240 BS-PCIB600 6” BS-PC36240 BS-PCIB1200 10” BS-PC42240 BS-PCIB600 6” BS-PC42240 BS-PCIB1200 10” BS-PC48240 BS-PCIB1200 10” BS-PC54240 BS-PCIB1200 10” BS-PC60240 BS-PCIB1200 10” BS-PC66240 BS-PCIB1200 10” IMP...
Page 21 - INSTALLATION OF YOUR PYRAMID STYLE HOOD BLOWER; INSTALLATION OF BS-PCIB600 INTERNAL BLOWER KIT
P/N 750306 Page 21 INSTALLATION OF YOUR PYRAMID STYLE HOOD BLOWER INSTALLATION OF BS-PCIB600 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM 1. REMOVE SHIPPING BRACKET(SEE ITEM 1) FROM HOOD. DO NOT DISCARD SCREWS! 2. INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET. 3. LOCATE THE...
Page 22 - INSTALLATION GUIDE FOR FLUE (PYRAMID STYLE HOOD)
INSTALLATION GUIDE FOR FLUE (PYRAMID STYLE HOOD) 1. MEASURE FROM TOP OF THE CANOPY TO CEILING AND SUBTRACT 1/8" FOR CLEAR- ANCE. 2. PLACE THE DUCT COVER TOP INSIDE THE DUCT COVER BASE AND LOWER UNTIL DE- SIRED HEIGHT IS FOUND. (TO ELIMINATE SCRATCHES, MAKE A MARK ON THE DUCT COVER TOP FOR THE DE...
Page 23 - DIMENSIONS OF THE LOW PROFILE SERIES HOOD
DIMENSIONS OF THE LOW PROFILE SERIES HOOD INLET LOCATION FOR THE ELECTRICAL CONNECTION IS LOCATED ON TOP FOR STANDARD TOP EXHAUST AND ON REAR FOR OPTIONAL REAR EXHAUST. (SEE DETAIL BELOW) ELECTRICAL REQUIREMENTS: 15 AMPS AT 120 VOLTS LIGHT BULBS ARE HALOGEN G9, 120V, 25W BULBS ARE OPERAT...
Page 24 - SITE PREPARATION FOR LOW PROFILE SERIES HOOD
IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MOST USERS. IF MOUNTED AT A HEIGHT GREATER T...
Page 25 - THE CORRECT HEIGHT OF YOUR LOW PROFILE SERIES
THE CORRECT HEIGHT OF YOUR LOW PROFILE SERIES THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72" ABOVE THE FLOOR. THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN 72" ABOVE THE F...
Page 26 - LOW PROFILE HOOD WIRING
LOW PROFILE DUCT INFORMATION TRC8/6 TRANSITION IS AVAILABLE TO INCREASE THE DUCT SIZE TO 8” FOR OPTIMAL PERFORMANCE IMPORTANT PLANNING INFORMATION! PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM. ALL CFM’S ARE BASED ON TESTS AT 0...
Page 27 - DIMENSIONS OF THE RE-CIRCULATING HOOD
DIMENSIONS OF THE RE-CIRCULATING HOOD INLET LOCATION FOR THE ELECTRICAL CONNECTION IS LOCATED ON TOP OR REAR. (SEE DETAIL BELOW) ELECTRICAL REQUIREMENTS: 15 AMPS AT 120 VOLTS LIGHT BULBS ARE HALOGEN G9, 120V, 25W BULBS ARE OPERATED BY A DIMMER SWITCH BLOWER IS VARIABLE SPEED P/N 75030...
Page 28 - SITE PREPARATION FOR RE-CIRCULATING HOOD
IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD, TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING. A HEIGHT OF 30", MINIMUM HEIGHT OFF OF COOKING SURFACE, TO 36" MAXIMUM HEIGHT OFF OF THE COOKING SURFACE, WILL SUIT MOST USERS. IF MOUNTED AT A HEIGHT GREATER T...
Page 29 - THE CORRECT HEIGHT OF YOUR RE-CIRCULATING HOOD; RE-CIRCULATING HOOD WIRING
THE CORRECT HEIGHT OF YOUR RE-CIRCULATING HOOD THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" TO 72" ABOVE THE FLOOR. THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN 72" ABOVE THE ...
Page 30 - CLEANING AND MAINTENANCE; YOUR HOOD MUST BE KEPT CLEAN AND MAINTAINED PROPERLY!!; CANOPY
CLEANING AND MAINTENANCE YOUR HOOD MUST BE KEPT CLEAN AND MAINTAINED PROPERLY!! BAFFLE FILTERS BAFFLE FILTERS SHOULD BE EXAMINED PERIODICALLY TO ASSURE THAT ALL SUR-FACES AND PARTS ARE CLEAN THE FILTERS ARE DISHWASHER SAFE OR IN A SINK WITH HOT, SOAPY WATER EASY PERIODIC CLEANING WILL ASSUR...
Page 31 - Failure to send a complete; WARRANTY
WHAT IS COVERED? Prizer-Painter provides the following limited warranties to the original retail purchasers of Products sold and installed in the continental United States and Canada on or after February 22, 2002: Initial Seven (7) Day Limited Warranty. Prizer-Painter warrants that all cosmetic comp...
Page 32 - WHAT IS NOT COVERED?
WHAT IS NOT COVERED? This Limited Warranty is the sole and exclusive warranty provided for the Product and extends only to original retail purchasers in the continental United States and Canada. This Limited Warranty is not trans-ferable to any subsequent purchasers or users. If any implied warranti...
Page 33 - PERFORMANCE CHECKLIST
This checklist has been developed to assure proper installation of your appliance To validate your warranty you must mail or fax this form and a copy of your receipt to: Warranty Department, Prizer-Painter, 600 Arlington Street, Reading, PA 19611, Fax (610) 376-2596 Customer Information (Please Prin...