Page 2 - ii; FCC and Industry Canada RF Interference Statements; Reorient or relocate the receiving antenna.; CAUTION
ii FCC and Industry Canada RF Interference Statements Class A This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been...
Page 3 - iii; Normas Oficiales Mexicanas (NOM) Electrical Safety Statement; Instrucciones de Seguridad
iii This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Product Description Version FCC Class A FCC Class B Dual AC 9 Dual DC 9 20-Slot Rackmount Chassis ACDC 9 AC 9 Dual AC 9 DC 9 ...
Page 4 - iv; Servicio por personal calificado deberá ser provisto cuando:
iv 11. El aparato eléctrico deberá ser conectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra física y la polarización del equipo no sea eliminada. 13. Los cables de la fuente ...
Page 5 - Table of Contents
v Table of Contents FCC and Industry Canada RF Interference Statements ................................. ii Normas Oficiales Mexicanas (NOM) Electrical Safety Statement ..................iii Part Numbers ............................................................................................. 1 ...
Page 6 - DC Power Supply Wiring Instruction
vi DC Power Supply Wiring Instruction s .............................................................. 14 User-Replaceable Power Supplies ............................................................... 14 Fans .............................................................................................
Page 8 - SNMP Management Module includes Black Box and iView2
2 3-Slot Desktop Chassis Part Number Power Supply 2 LMC5233A 3-Slot, w/AC Power LMC5234A 3-Slot, w/Dual AC Power LMC5235A 3-Slot, w/DC Power LMC5236A 3-Slot, w/Dual DC Power LMC5237A 3-Slot, w/ ACDC Power Back Up, Spares, Sold Separately Part Number Description LMC5200A SNMP Management Module includ...
Page 9 - Power Supply Modules
3 About the 20-Slot Rackmount Chassis The 20-Slot Rackmount Chassis series is a modular chassis platform designed for use with Black Box Simple Network Management Protocol (SNMP) manageable series of modules. The 20-Slot Rackmount Chassis is a 3U high, Rackmountable chassis that features 20 slots fo...
Page 10 - status of; NOTE; Leave this switch in the; SNMP Management Module LEDs
4 Reset Alarm Button When one power supply module malfunctions, an audible alarm sounds indicating the loss of the power module. The alarm can be silenced by pressing the Alarm Reset Button, located next to the power connector on the power supply module. If this occurs, remove and replace the power ...
Page 11 - PS; Glows yellow when one module malfunctions.; Installing the 20-Slot Rackmount Chassis; Plug the chassis into a reliable, filtered power source.
5 LNK/ACT FDX/COL TEMP PS FAN A / FAN B Glows green when a link is established on port. Blinks green when data activity occurs. Glows yellow when port is in Full-Duplex mode. Blinks yellow when port is operating in Half-Duplex mode and collisions occur. Glows yellow when temperature of unit surpasse...
Page 12 - chassis will not function, but no damage will occur.
6 7. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring. 8. Reliable Grounding - Reliable grounding of Rackmounted equipment should be mai...
Page 13 - Installing SNMP Management and Application Modules; To install a module:; media conversion and mode conversion modules in this slot.
7 Installing SNMP Management and Application Modules To install a module: 1. Remove the blank bracket (if present) covering the slot where the module will be installed. Black Box recommends installing blank brackets in unused module slots. 2. Slide the module into the chassis using the card guides. ...
Page 14 - To replace a power supply module:
8 Replacing Power Supply Modules User-Replaceable Power Supply Modules While power supply modules are redundant, failed power supply modules should promptly be replaced to maintain network integrity and prevent data loss. To replace a power supply module: 1. Disconnect the power source from the powe...
Page 15 - Do not mix AC and DC power supply modules.
9 Dual DC, Part Number LMC5208A-R2 NOTE Do not mix AC and DC power supply modules.
Page 16 - ACDC, Part Number LMC5228A; 0-Slot Rackmount Chassis Specifications
10 ACDC, Part Number LMC5228A NOTE For LMC5228A 20-Slot Rackmount Chassis, all models in that model number series can support Dual AC, Dual DC or ACDC. The power supply modules for that model number series are interchangeable. 20-Slot Rackmount Chassis Specifications Input Specifications Dual AC 100...
Page 17 - About the 6-Slot Rackmount/Desktop Chassis; The; -Slot Rackmount/Desktop Chassis Features
11 About the 6-Slot Rackmount/Desktop Chassis The 6-Slot Rackmount/Desktop Chassis, is a modular chassis platform designed for use with Black Box Simple Network Management Protocol (SNMP) manageable series of modules. The 6-Slot Rackmount/Desktop Chassis is 1U high, Rackmountable, and supports optio...
Page 18 - of features
12 • Both power supply modules malfunction • Both power supply modules are powered down • When the AC line fails Temperature Gauge The 6-Slot Rackmount/Desktop Chassis includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis. Users define a threshold for chassis tem...
Page 19 - Glows yellow when a fan malfunctions.; Installing the 6-Slot Rackmount/Desktop Chassis
13 LNK/ACT FDX/COL TEMP PS FAN A / FAN B Glows green when a link is established on port. Blinks green when data activity occurs. Glows yellow when port is in Full-Duplex mode. Blinks yellow when port is operating in Half-Duplex mode and collisions occur. Glows yellow when temperature of unit surpass...
Page 20 - DC Power Wiring, Replacing Power Supply and Fans; User-Replaceable Power Supplies; To install a second power supply:; Fans
14 8. Reliable Grounding - Reliable grounding of Rackmounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips). 9. All AC and DC versions are intended for use in a Restricted Acce...
Page 23 - About the 3-Slot Desktop Chassis; The 3-Slot Desktop Chassis series; is a modular chassis platform designed for use with Black Box; Desktop Chassis; modules, and supports a SNMP Management Module.; -Slot Desktop Chassis Features; Both power supply modules are powered down
17 About the 3-Slot Desktop Chassis The 3-Slot Desktop Chassis series is a modular chassis platform designed for use with Black Box Simple Network Management Protocol (SNMP) manageable series of modules. The 3-Slot Desktop Chassis is a 1U high, a Rackmountable, capable of offering redundant power su...
Page 24 - Install the 3-Slot Desktop Chassis by placing it on a flat surface.
18 Temperature Gauge The 3-Slot Desktop Chassis includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis. Users define a threshold for chassis temperature via SNMP. If the chassis’ temperature rises above the specified level, the SNMP agent sends a trap (configured ...
Page 25 - Negative ground system configuration (default position); Incorrect wiring will result in chassis malfunction.
19 7. A readily accessible disconnect device shall be incorporated in the building installation wiring. 8. A suitable listed circuit breaker shall be provided in the building installation as the unit’s disconnect device. The branch circuit rating (i.e. minimum 15A listed circuit breaker, etc.). DC P...
Page 26 - -Slot Desktop Chassis; includes temperature-triggered fans. When the temperature of the; Installing Management and Application Modules
20 Fans The 3-Slot Desktop Chassis includes temperature-triggered fans. When the temperature of the chassis reaches 40° C, the two fans activate to cool the chassis. The fans’ operation can be tested by holding the Alarm Reset Button down for 4 to 5 seconds. The fans will activate and then they will...
Page 27 - SNMP Write Lock; features
21 SNMP Write Lock The SNMP Write Lock switch is located on the back of the 3-Slot Desktop Chassis. The SNMP Write Lock switch prevents a new management board from re-configuring the application module settings (e.g., the status of features such as LinkLoss, FiberAlert, Force mode, etc.) made via SN...
Page 29 - Black Box Corporation; WARNING; Disconnect all power supplies before servicing.
23 Black Box Customer Service Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) Free technical support , 24 hours a day, 7 days a week. Call: 724-746-5500 or Fax: 724-746-0746 Mail order: Black Box Corporation 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.black...
Page 30 - Integrated circuits and fiber optic components are
24 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber p...
Page 31 - Certifications
25 Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. European Directive 2002/96/EC (WEEE) requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste. This symbol ...