Page 4 - Introduction on the Switch
Express Ethernet Switch: LB9017A-R3 3 About This Manual Preface This manual describes how to install and use the 16 Ports Web-based Smart Ethernet Switch. The TX ports of the switch introduced here auto-negotiates the presence of 10/100Mbps and full/half-duplex mode and auto-MDIX. In addition, it al...
Page 5 - Table of Contents
Express Ethernet Switch: LB9017A-R3 4 Table of Contents About This Manual......................................................................................................................................................3 Preface ......................................................................
Page 6 - Product Overview; Front View; Figure 1: 16 Ports Web-based Smart Ethernet Switch; Package Contents; The 16 Ports Switch; User’s Manual
Express Ethernet Switch: LB9017A-R3 5 Product Overview Front View Figure 1: 16 Ports Web-based Smart Ethernet Switch Package Contents When you unpack the product package, you shall find these items listed below. 3 The 16 Ports Switch 3 One AC power cord 3 User’s Manual Please inspect the contents, a...
Page 7 - Product Features; FX
Express Ethernet Switch: LB9017A-R3 6 Product Features ♦ P ROVIDES 16 × 10/100M BPS PORTS USING RJ-45 CONNECTORS ♦ A N OPTIONAL SINGLE - PORT FIBER MODULE ALLOWS : - 100B ASE FX MULTI - MODE FIBER WITH SC, ST, MT-RJ, VF-45 OR LC CONNECTOR - 100B ASE FX SINGLE - MODE FIBER WITH SC CONNECTOR ♦ A UTO -...
Page 8 - Front Panel Display; Figure 3: Front Panel LEDs; Power; Understanding Front Panel Design; Console
Express Ethernet Switch: LB9017A-R3 7 Front Panel Display The LED indicators on the front panel provide you with instant feedback on each port status, and help you monitor and troubleshoot the switch. Figure 3: Front Panel LEDs Power This LED comes on when the switch is properly connected to power a...
Page 9 - Port LED; Installation; Selecting a Site for the Equipment
Express Ethernet Switch: LB9017A-R3 8 Flashing Transmitting or receiving data ACT stands for ACTIVITY ACT Off Neither transmitting nor receiving data On A valid network connection LNK stands for LINK Flashing Transmitting or receiving data ACT stands for ACTIVITY LNK/ACT Off Neither connection nor a...
Page 10 - Installation and Placement Instructions; Mounted to 19-inch standard rack
Express Ethernet Switch: LB9017A-R3 9 Installation and Placement Instructions Mounted to 19-inch standard rack Locate the accessories supplied in the product package. Use the rackmount brackets and screws to install the switch into any EIA 19” standard rack. Step 1: Attach the brackets to each side ...
Page 11 - Optional Fiber Module Installation; Figure 4: Removal of cover plate Fiber module being installed
Express Ethernet Switch: LB9017A-R3 10 Optional Fiber Module Installation Consult the following illustrations before installation. Step 1: Make sure the power is switched off. The module is not hot-swappable. L It may cause electric shock or any possible damage to the switch if the power is not swit...
Page 12 - Connecting to Power; Locate the supplied AC power cord.; Figure 5: Rear view of the switch; Connecting to Your Network; Cabling
Express Ethernet Switch: LB9017A-R3 User’s Manual 11 Connecting to Power Locate the supplied AC power cord. Step 1: Connect the AC power cord to the receptacle at the back of the switch. Step 2: Attach the plug into a standard AC outlet with a voltage range from 100~240Vac. Step 3: The power LED on ...
Page 13 - Network Segmentation
Express Ethernet Switch: LB9017A-R3 User’s Manual 12 Network Segmentation The maximum segment distance between a node and a directly connected switch port on a 100BaseFX network is 75km using 10/125 (or 9/125)µm single-mode fiber optic cable. It is capable of a maximum span of 2km when 62.5/125 (or ...
Page 14 - Switch Configuration; Setting up Console Port Connection (Web-Based Browser Interface); Switch IP Address; In your web browser, specify the; default IP address; of the Ethernet Switch; User Name; Enter the factory default user name:; admin; Password; Enter the factory default password (no password,; press Enter directly
Express Ethernet Switch: LB9017A-R3 User’s Manual 13 Switch Configuration Setting up Console Port Connection (Web-Based Browser Interface) The Ethernet Switch provides a browser interface that lets you configure and manage the Ethernet Switch from a Web browser (such as Microsoft Internet Explorer o...
Page 15 - Main Menu; The; System Change; parameters can be displayed by clicking the; System Change; button in the; Please restart
Express Ethernet Switch: LB9017A-R3 User’s Manual 14 Main Menu System Change The System Change parameters can be displayed by clicking the System Change button in the left sub-menu. z Switch Name: Type a switch name and replace the current switch name with a new one. ( Please restart your Computer o...
Page 16 - button and apply the new System settings.; IP Configuration; Refresh; button and refresh back to the last saved IP Configurations.; Apply; button and apply the new IP Configurations.
Express Ethernet Switch: LB9017A-R3 User’s Manual 15 z Password: Enter a user-defined password and change the factory default password. <Note> ( Only “ a-z “, “A-Z”, “0-9”, “under line” & “Space” can be acceptable, totally can not exceed 16 characters ). z Apply: Click the Apply button and...
Page 17 - Port
Express Ethernet Switch: LB9017A-R3 User’s Manual 16 Port z Refresh: Click the Refresh On or Refresh Off button to or not to refresh back to the last saved settings of the ports. <Note> It is recommended to change the Refresh On button to Refresh Off while you change the settings of the ports....
Page 18 - VLAN; VLAN: Click and choose the ports to be added into the VLAN groups.; button and apply the new settings of the VLAN groups.
Express Ethernet Switch: LB9017A-R3 User’s Manual 17 VLAN z VLAN: Click and choose the ports to be added into the VLAN groups. z Apply: Click the Apply button and apply the new settings of the VLAN groups. <Note> All Ports have to be selected to one of the VLAN Groups, those Port/Ports were no...
Page 19 - Trunking; 6 Ports Ethernet Switch:
Express Ethernet Switch: LB9017A-R3 User’s Manual 18 Trunking 16 Ports Ethernet Switch: z Disable: Click and choose the Disable to disable the Trunking Group 1 or Trunking Group 2. z Trunking Group 1: Click and choose the Port 1, 2 to be added into the Trunking Group 1. z Trunking Group 2: Click and...
Page 20 - Save Configuration
Express Ethernet Switch: LB9017A-R3 User’s Manual 19 Save Configuration z Click Save Configuration . z Click the Ok or Cancel button to or not to save the configurations. <Note> The Cancel button will discard any data you have changed since the last "Save" operation. Without clicking O...
Page 21 - Load Default; Technical Specifications; 6 Ports Web-based Smart Ethernet; Sixteen ports for the 16-Port Switch
Express Ethernet Switch: LB9017A-R3 User’s Manual 20 Load Default z Click Load Default . z Click the Ok or Cancel button to or not to load the default settings. < Note > Once the Ok button is selected, all last saved Port , VLAN , and Trunking setting will revert back to the default settings. ...
Page 22 - Physical Specifications
Express Ethernet Switch: LB9017A-R3 User’s Manual 21 Physical Specifications 16 Ports Web-based Smart Ethernet Switch Dimensions 17.3 x 8.2 x 1.74 in. ( W440 × D207 × H44 mm ) 19” rack mount size, 1U high Weight Approximately 6.2 pounds ( 2.8kg ) Power Input 100 ~ 240 VAC, 50~60 Hz Input Fuse 16 Por...
Page 23 - Connector Pinouts; Figure 6: RJ-45 Connector and Cable Pins; The following table lists the pinout of 10/100BaseT/TX ports.
Express Ethernet Switch: LB9017A-R3 User’s Manual 22 Connector Pinouts Pin arrangement of RJ-45 connectors: Figure 6: RJ-45 Connector and Cable Pins The following table lists the pinout of 10/100BaseT/TX ports. Connector Pin-Out Pin Regular Ports Uplink port 1 Input Receive Data + Output Transmit Da...
Page 24 - Express Ethernet Switch; Ordering Information; 6 Fixed Ports
Express Ethernet Switch 23 Ordering Information 16 Fixed Ports Single-Port Module Cable Connector Distance Speed Cable (/125µm) Connector Distance 3 100BaseFX MMF (50µm or 62.5µm) SC 2km 100BaseFX MMF (50µm or 62.5µm) ST 2km 100BaseFX MMF (50µm or 62.5µm) MT-RJ 2km 100BaseFX MMF (50µm or 62.5µm) VF-...