Page 2 - TABLE OF CONTENTS; INFORMATION
724-746-5500 | blackbox.com Page 2 Black Box G.SHDSL.bis EFM CPE TABLE OF CONTENTS 1. GENERAL INFORMATION ......................................................................... 9 1.1 Features .............................................................................................. 91.2 Descr...
Page 3 - Table of Contents
724-746-5500 | blackbox.com Page 3 Table of Contents 5.1 Establishing a Remote Console Session .......................................... 29 5.1.1 How to Connect ..................................................................... 29 5.1.2 How to Disconnect ............................................
Page 5 - RADIO FREQUENCY INTERFERENCE STATEMENTS
724-746-5500 | blackbox.com Page 5 RADIO FREQUENCY INTERFERENCE STATEMENTS RADIO FREQUENCY INTERFERENCE STATEMENTS FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installe...
Page 6 - INSTRUCCIONES DE SEGURIDAD; (Normas Oficiales Mexicanas Electrical Safety Statement)
724-746-5500 | blackbox.com Page 6 Black Box G.SHDSL.bis EFM CPE INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement) 4. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 5. Las instrucciones de seguridad...
Page 10 - GENERAL INFORMATION
724-746-5500 | blackbox.com Page 10 Black Box G.SHDSL.bis EFM CPE 1. GENERAL INFORMATION Thank you for your purchase of this Black Box product. This product has been thor-oughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installa...
Page 11 - POWER INPUT CONNECTOR; • Rated voltage: 5 VDC; Power connection barrel receptacle 5 VDC diagram; CAUTION
724-746-5500 | blackbox.com Page 11 Figure 1. LB510A-R2 1.3 POWER INPUT CONNECTOR The LB510A-R2 comes with an AC or DC power supply. (See Appendix A.7 on page 36.) The power connection to the CPE is a 2.5 mm barrel receptacle with the center con-ductor positive (see figure 2). • Rated voltage: 5 VDC...
Page 13 - Configuration; The table below lists the LB510A-R2’s configurable parameter.
724-746-5500 | blackbox.com Page 13 Configuration hardware (DIP-switch)-configuration mode. In DIP-switch-configuration mode the device will read the DIP-switch settings during system startup and configure itself according to the switch settings. Once you power-up the LB510A-R2 in DIP-switch mode, i...
Page 14 - CONFIGURING THE DIP SWITCHES; Underside of LB510A-R2 showing location of DIP switches
724-746-5500 | blackbox.com Page 14 Black Box G.SHDSL.bis EFM CPE 2.3 CONFIGURING THE DIP SWITCHES The LB510A-R2 is equipped with three sets of DIP switches, which you can use to configure the modem for a broad range of applications. This section describes switch locations and discusses the configur...
Page 15 - SYSTEM RESET MODE; Position
724-746-5500 | blackbox.com Page 15 Configuration The three sets of DIP switches on the underside of the LB510A-R2 are referred to as S1, S3 and S4. For basic configuration, use DIP switch S1. For testing the LB510A-R2, use DIP switch S3. To con-figure the rate, use DIP switch S4. This figure shows ...
Page 16 - S4-2 through S4-8 Data Rate DIP switch settings
724-746-5500 | blackbox.com Page 16 Black Box G.SHDSL.bis EFM CPE Table 3: LB510A-R2 S3 DIP-Switch functions (test modes and patterns) 2.5.1 Switches S4-2 through S4-8 define the DSL line rate Table 4: S4-2 through S4-8 Data Rate DIP switch settings S1-5 Ethernet Port 0 Management(Eth 0 is used for ...
Page 19 - ETHERNET MANAGEMENT PORT
724-746-5500 | blackbox.com Page 19 2.6 ETHERNET MANAGEMENT PORT The LB510A-R2 offers a 10/100 Ethernet port for configuration and management via Telnet sessions. Because the Ethernet port is configured as MDI, a crossover Ethernet cable is required when connecting directly from a local PC or laptop...
Page 20 - that still allows for BER of less than 1x 10–; • DSL Error Counters: The following error counters are available:
724-746-5500 | blackbox.com Page 20 Black Box G.SHDSL.bis EFM CPE • DSL Sync State: Out of Sync, Acquiring Sync, In Sync, or Losing Sync. NOTE: DSL Link State vs. DSL Sync State—The DSL link state describes whether the DSL is training (in progress), linked (success), deactivated (we don’t have an op...
Page 23 - Safety When Working With Electricity
724-746-5500 | blackbox.com Page 23 Safety When Working With Electricity losw: 0 LB301A-R2> system show status configuration mode: software dsl test mode: loopback: off pattern: off errors: 0 dsl link state: idle interface dsl efm: mii txpackets: 0 mii rxpackets: 1 efm txpackets: 0 efm rxpackets:...
Page 24 - CONNECTING THE DSL INTERFACE; Two things are essential:
724-746-5500 | blackbox.com Page 24 Black Box G.SHDSL.bis EFM CPE 3. INSTALLATION Once the LB510A-R2 is properly configured, it is ready to connect to the DSL interface and to the power source. This section explains how to make these connections. Figure 4. LB510A-R2 rear panel 3.1 CONNECTING THE DSL...
Page 25 - Installation; CONNECTING THE ETHERNET INTERFACE; on the universal input power supply.; Connect the barrel plug to the Power connector on the LB510A-R2.
724-746-5500 | blackbox.com Page 25 Installation The RJ-45 DSL connector on the LB510A-R2’s twisted pair interface is polarity insen-sitive and is wired for a two-wire interface. 3.2 CONNECTING THE ETHERNET INTERFACE This section describes how to connect the Ethernet ports to your network equipment....
Page 26 - DC Power Supply; LED STATUS MONITORS; WARNING
724-746-5500 | blackbox.com Page 26 Black Box G.SHDSL.bis EFM CPE 3.3.2 DC Power The 36-60 VDC DC to DC adapter is supplied with the DC version of the LB510A-R2. The black and red leads plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel power supply jack on th...
Page 27 - Operation
724-746-5500 | blackbox.com Page 27 Operation Figure 6. LB510A-R2 front panel 4.2.1 Power (Green) The Power LED glows solid during normal operation. At startup, during the POST, the LED blinks once every second. If the POST fails, the unit does not enter normal opera-tion, and the LED blinks once ev...
Page 29 - Remote console operation; Remote digital loopback diagram; REMOTE CONSOLE OPERATION
724-746-5500 | blackbox.com Page 29 Remote console operation Figure 9. Remote digital loopback diagram The RDL causes the remot unit to loop the data received from the DSL line back tow the DSL line. 4.3.2 Patterns The LB510A-R2 can generate and detect 511 patterns. These can be initiated either by ...
Page 30 - Remote control session diagram; ESTABLISHING A REMOTE CONSOLE SESSION
724-746-5500 | blackbox.com Page 30 Black Box G.SHDSL.bis EFM CPE Figure 10. Remote control session diagram 5.1 ESTABLISHING A REMOTE CONSOLE SESSION 5.1.1 How to Connect The following steps are to establish a connection to the remote LB510A-R2 (far-end) via Remote Console Session (RCS): 1. Connect ...
Page 31 - Opening a typical remote console session
724-746-5500 | blackbox.com Page 31 Remote console operation NOTE: The passwords for a local console session of the LB510A-R2 (near-end) and the remote console session of the LB510A-R2 (far-end) should be different for the pur-pose of security. 7. You should now be logged into the remote LB510A-R2 (...
Page 32 - • The user enters the command logout; • The DSL link drops.; Console: Remote console connection established.; Differences in local and remote control session behavior
724-746-5500 | blackbox.com Page 32 Black Box G.SHDSL.bis EFM CPE 5.1.2 How to Disconnect The remote console session ends under any of the following conditions: • The user enters the command logout • A timeout period of 5 minutes elapses since the user has entered a command to the console. • The DSL...
Page 33 - Software Upgrade; Remote control session with LAL diagram; and far-end LB510A-R2 NTU’s can no longer communicate over the RCS.; SOFTWARE UPGRADE; Enter the system show info command to view the unit’s MAC address.; to begin the upgrade.; Alternatively, you may enter the system upgrade
724-746-5500 | blackbox.com Page 33 Software Upgrade Figure 12. Remote control session with LAL diagram • dsl set loopback lal: do not issue this command over the RCS to the far-end LB510A-R2. if the far-end goes into Local Analog Loopback (LAL), the near-end and far-end LB510A-R2 NTU’s can no longe...
Page 34 - RESET CONFIGURATION TO FACTORY DEFAULTS
724-746-5500 | blackbox.com Page 34 Black Box G.SHDSL.bis EFM CPE 7. RESET CONFIGURATION TO FACTORY DEFAULTS The configuration can be reset to factory defaults using DIP switch S1. A factory reset allows a user to recover from a forgotten password. To reset to the configuration: 1. Turn the LB510A-R...
Page 35 - Reset configuration to factory defaults; Internal, external or receive recovered; A.3 ETHERNET INTERFACE
724-746-5500 | blackbox.com Page 35 Reset configuration to factory defaults A. SPECIFICATIONS A.1 CLOCKING MODES Internal, external or receive recovered A.2 DTE RATE All 64k steps from 64 to 5696 kbps A.3 ETHERNET INTERFACE • Four RJ-45 • 10/100base-t • IEEE802.3 Ethernet A.4 DIAGNOSTICS V.52 compli...
Page 36 - A.7 POWER AND POWER SUPPLY SPECIFICATIONS; The CPE comes with either an AC or DC power supply; Power connections barrel receptacle 5 VDC diagram; AC; UNIVERSAL; • Output from power supply 5 VDC, 2A
724-746-5500 | blackbox.com Page 36 Black Box G.SHDSL.bis EFM CPE The Activity LED shows that there is data being transferred over that port. During a software upgrade procedure, if the Activity LED is on for extended time, a problem with the upgrade has occured and the device should be restarted. T...
Page 37 - XTERNAL; A.8 TRANSMISSION LINE
724-746-5500 | blackbox.com Page 37 Reset configuration to factory defaults A.7.2 E XTERNAL 48 VDC POWER SUPPLY • Input -Rated voltage 36–60 VDC -Rated current 0.25 A DC • Output -Rated voltage 5 VDC 5%, 5W -Rated current 1 A DC -6-inch cable terminated with 2.5 mm barrel plug, center positive • Iso...
Page 38 - B. FACTORY DEFAULT VALUES; Parameter
724-746-5500 | blackbox.com Page 38 Black Box G.SHDSL.bis EFM CPE A.13 TEMPERATURE RANGE 32–122°F (0–50°C) A.14 HUMIDITY 5–95% non-condensing A.15 ALTITUDE 0–15,000 feet (0–4,600 meters) A.16 DIMENSIONS 6.22 W x 1.25 H x 4.75 D in. (157 W x 318 H x 120 D mm) A.17 THIRD PARTY SOFTWARE LICENSES NOTE: ...
Page 39 - C. INTERFACE PINOUTS; SOCKET
724-746-5500 | blackbox.com Page 39 Reset configuration to factory defaults C. INTERFACE PINOUTS C.1 LINE PORT C.1.1 RJ-45 • Pin 4: Tip • Pin 5: Ring • Pins 1, 2, 3, 6, 7, 8: no connection C.2 ETHERNET PORT C.2.1 RJ-45 SOCKET 10/100B ASE -T • Pin 1: TX+ • Pin 2: TX- • Pin 3: RX+ • Pin 6: RX- NOTE: P...