Avocent 1500 - Manuals
Avocent 1500 – Manual in PDF format online.
Manuals:
Manual Avocent 1500
Summary
INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated danger- ous voltage within t...
AutoView ® 1400/1500/2000 Installer/User Guide Avocent, the Avocent logo, The Power of Being There, AutoView, OutLook and OSCAR are registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners. © 2006 Avocent Corporation. All rights rese...
iii Table of Contents List of Figures .................................................................................................................. v List of Tables .................................................................................................................. vii Chapter 1: ...
iv AutoView 1400/1500/2000 Installer/User Guide Chapter 4: Advanced Operations ................................................................................. 39 Using Administrator Privileges ....................................................................................................... 3...
v List of Figures Figure 1.1: Example of an AutoView Switch Configuration ............................................................. 3 Figure 2.1: AutoView Switch Horizontal Installation ...................................................................... 6 Figure 2.2: Basic AutoView Switch Con...
vii List of Tables Table 2.1: Legacy Switch Support ................................................................................................... 10 Table 3.1: OSCAR Interface Status Symbols ................................................................................... 16 Table 3.2: OSCAR...
1 C H A P T E R 1 Product Overview Features and Benefits The AutoView ® 1400/1500/2000 switches integrate Avocent field-proven analog keyboard, video and mouse (KVM) switching technology with advanced cable management, flexible access for two simultaneous users and a patented, easy-to-use interface....
Chapter 1: Product Overview 3 a class of user can access, as well as the name of the user account and password. See Chapter 4 for more information. Integrated Access Cables The AutoView 1400/1500/2000 switches also feature Integrated Access Cable (IAC) modules designed to provide the same ease of us...
4 AutoView 1400/1500/2000 Installer/User Guide Safety Precautions To avoid potential video and/or keyboard problems when using Avocent products: • Ι f the building has 3-phase AC power, ensure that the computers and monitors are on the same phase. For best results, they should be on the same circuit...
5 C H A P T E R 2 Installation Getting Started Before installing your AutoView switch, refer to the following list to ensure you have all items that shipped with the AutoView switch, as well as other items necessary for proper installation. Supplied with the AutoView switch • Power cord • One null m...
6 AutoView 1400/1500/2000 Installer/User Guide Figure 2.1: AutoView Switch Horizontal Installation CAUTION: Rack Loading - Overloading or uneven loading of racks may result in shelf or rack failure, causing damage to equipment and possible personal injury. Do not exceed your rack load rating. To ins...
Chapter 2: Installation 7 CAUTION: To reduce the risk of electric shock or damage to your equipment - - Do not disable the power cord grounding plug. The grounding plug is an important safety feature.- Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times. - Dis...
8 AutoView 1400/1500/2000 Installer/User Guide To connect a server using an AVRIQ module: 1. Locate the AVRIQ modules for your AutoView switch. 2. Attach the appropriately color-coded cable ends to the keyboard, monitor and mouse ports on the first server you will be connecting to the appliance. 3. ...
Chapter 2: Installation 9 In this configuration, the local port OSCAR interface is disabled in switches cascaded below the main AutoView switch. To cascade multiple AutoView switches: 1. Connect the cascaded AutoView switch to each server as described in the previous Installing the AutoView Switch s...
10 AutoView 1400/1500/2000 Installer/User Guide Figure 2.3: AutoView 2000 Switch Configuration with a Cascaded Switch Adding Legacy Switches You can add legacy switches to the AutoView switching system for easy integration into your existing configuration. In a cascaded system, each ARI port will ac...
Chapter 2: Installation 13 To add a legacy KVM switch: 1. Mount the primary KVM switch into your rack cabinet. 2. Connect one end of a CAT 5 cable to an available port on the back of your AutoView switch. 3. Attach the keyboard, monitor and mouse connectors of the AVRIQ module to a user port on your...
15 C H A P T E R 3 Basic Operations Controlling Your System at the Analog Ports The AutoView switch features one or two analog port sets on the back of the switch that allow you to connect a monitor and a PS/2 keyboard and mouse for direct analog access. The AutoView switch uses the OSCAR interface,...
16 AutoView 1400/1500/2000 Installer/User Guide NOTE: You can also press the Control key twice, the Alt key twice or the Shift key twice within one second to launch the OSCAR interface. See Changing the display behavior later in this chapter for further details. You can use this key sequence in any ...
Chapter 3: Basic Operations 17 To select the previous server: Press Print Screen and then Backspace . This key combination toggles you between the previous and current connections. To disconnect the user from a server: Press Print Screen and then Alt+0 . This leaves the user in a free state, with no...
Chapter 3: Basic Operations 19 Configuring OSCAR Interface Menus You can configure your AutoView switch from the Setup menu within the OSCAR interface. Select the Names button when initially setting up your switch to identify servers by unique names. Select the other setup features to manage routine...
20 AutoView 1400/1500/2000 Installer/User Guide Figure 3.2: Setup Dialog Box Assigning server names Use the Names dialog box to identify individual servers by name rather than by port number. The Names list is always sorted by port order. Names are stored in the AVRIQ or IAC module, so even if you m...
Chapter 3: Basic Operations 21 To assign names to servers: 1. In the Names dialog box, select a server name or port number and click Modify . The Name Modify dialog box displays. Figure 3.4: Name Modify Dialog Box 2. Type a name in the New Name box. Names of servers may be up to 15 characters long. ...
22 AutoView 1400/1500/2000 Installer/User Guide Figure 3.5: Devices Dialog Box When the AutoView switch discovers a cascaded switch, you will notice the port numbering change to accommodate each server under that switch. For example, if the switch is connected to ARI port 6, the switch port would be...
Chapter 3: Basic Operations 23 Changing the display behavior Use the Menu dialog box to change the display order of servers, change the key sequence to launch the OSCAR interface and set a Screen Delay Time for the OSCAR interface. The display order setting alters how servers display in several scre...
24 AutoView 1400/1500/2000 Installer/User Guide Setting a Screen Delay Time allows you to complete a soft switch without the OSCAR interface displaying. To perform a soft switch, see Soft switching in this chapter. Setting the keyboard country code The AutoView 1400/1500/2000 switch can be configure...
Chapter 3: Basic Operations 25 5. Click OK for changes to take effect. Figure 3.9: Keyboard Warning Dialog Box Controlling the status flag The status flag displays on your desktop and shows the name or EID number of the selected server or the status of the selected port. Use the Flag dialog box to c...
26 AutoView 1400/1500/2000 Installer/User Guide Figure 3.10: Flag Dialog Box To determine how the status flag is displayed: 1. Select Name or EID to determine what information will be displayed. 2. Select Displayed to show the flag all the time or select Timed to display the flag for only five secon...
Chapter 3: Basic Operations 27 Once engaged, your console will remain locked until you press any key or move the mouse. You will then need to type in your password to continue. Use the Security dialog box to lock your console with password protection, set or change your password and enable the scree...
28 AutoView 1400/1500/2000 Installer/User Guide 3. Type the number of minutes for Inactivity Time (from 1 to 99) to delay activation of password protection and the screen saver feature. 4. For Mode, select Energy if your monitor is E NERGY S TAR ® compliant; otherwise select Screen . CAUTION: Monito...
Chapter 3: Basic Operations 29 4. Choose Energy if your monitor is E NERGY S TAR compliant; otherwise select Screen . CAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant with E NERGY S TAR . 5. (Optional) Click Test to activate the screen saver test which lasts...
30 AutoView 1400/1500/2000 Installer/User Guide To turn off the screen saver: 1. In the Security dialog box, clear Enable Screen Saver . 2. Click OK . To immediately turn on the screen saver: Press Print Screen , then press Pause . Displaying Version Information The OSCAR interface enables you to di...
Chapter 3: Basic Operations 31 Figure 3.14: Target Selection Dialog Box 4. Select an AVRIQ or IAC module to view and click the Version button. The Target Version dialog box displays. For more information on loading firmware, see Appendix A. Figure 3.15: Target Version Dialog Box 5. Click X to close ...
32 AutoView 1400/1500/2000 Installer/User Guide To add servers to the scan list: 1. If the OSCAR interface is not open, press Print Screen . The Main dialog box will appear. 2. Click Setup - Scan . The Scan dialog box displays. Figure 3.16: Scan Dialog Box 3. The dialog box contains a listing of all...
Chapter 3: Basic Operations 33 Figure 3.17: Commands Dialog Box NOTE: Figure 3.17 shows the Commands screen for the administrator and local user when the Enable User Accounts feature is turned off. The restricted user will only have access to the Display Versions, Device Reset and Log Out buttons. 3...
34 AutoView 1400/1500/2000 Installer/User Guide NOTE: AVRIQ or IAC modules may appear to be offline while being upgraded. Figure 3.18: Diagnostics Dialog Box Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to the left of each item as that test finish...
Chapter 3: Basic Operations 35 Figure 3.19: Diagnostics Warning Dialog Box 3. Click OK to begin diagnostics. -or-Click X or press Escape to exit the dialog box without running a diagnostic test. 4. All users are disconnected and the Diagnostics dialog box displays. 5. As each test is finished, a pas...
36 AutoView 1400/1500/2000 Installer/User Guide Figure 3.20: Broadcast Dialog Box NOTE: Broadcasting Keystrokes - The keyboard state must be identical for all servers receiving a broadcast to interpret keystrokes identically. Specifically, the Caps Lock and Num Lock modes must be the same on all key...
Chapter 3: Basic Operations 37 Figure 3.21: Broadcast Enable Confirm/Deny Dialog Box 5. Click OK to enable the broadcast. Click X or press Escape to cancel and return to the Com- mands dialog box. 6. If broadcasting is enabled, type the information and/or perform the mouse movements you want to broa...
38 AutoView 1400/1500/2000 Installer/User Guide Figure 3.22: Switch Dialog Box 3. Select either Preemptive or Cooperative as your Switch Mode. 4. Click OK to save changes. Click X or press Escape to cancel. Setting the Share Mode feature The Share Mode feature of the AutoView 1400/1500/2000 switches...
39 C H A P T E R 4 Advanced Operations Using Administrator Privileges The AutoView 1400/1500/2000 switches allow up to four users and one administrator to log into a switch, with the administrator having the ability to restrict users from accessing the targets via the Security menu. The administrato...
40 AutoView 1400/1500/2000 Installer/User Guide Figure 4.2: Setup Menu (Administrator Only) Figure 4.3: User Setup Menu (Administrator Only) User Setup menu functions (administrator only) The User Setup menu allows the administrator to edit, access and/or delete a user account. The menu is only acce...
Chapter 4: Advanced Operations 41 3. Click Access to restrict port access for the selected user. 4. Click Delete to restore the selected user to the default state (default name, no password, no port access). 5. Click OK on the User Setup screen to save changes, or click the Exit button to escape wit...
42 AutoView 1400/1500/2000 Installer/User Guide Figure 4.5: User Access Menu (Administrator Only) The Clear All button allows the administrator to clear access to all ports for a given user instead of deleting the account. The Check All button allows the administrator to assign all available KVM por...
43 Appendices Appendix A: Flash Upgrades Upgrading the AutoView switch You can upgrade the firmware of your AutoView switch by using a special update utility provided by Avocent. This utility automatically configures the port communications settings to allow direct downloading from the connected ser...
44 AutoView 1400/1500/2000 Installer/User Guide • Verify that a null modem serial cable is used. • In the selected COM port Advanced Port settings, verify that the FIFO buffers are selected and that the receive buffer is set to High. CAUTION: While upgrading, do not use your computer for anything el...
Appendices 45 Figure A.2: AVRIQ Upgrade Dialog Box To upgrade AVRIQ module firmware individually: 1. Press Print Screen . The Main dialog box will appear. 2. Click Commands - Display Versions . The Version dialog box displays. Figure A.3: Version Dialog Box 3. Click Target to view individual AVRIQ m...
48 AutoView 1400/1500/2000 Installer/User Guide Appendix B: Technical Specifications Table B.1: Product Specifications AutoView Switch Product Specifications ARI ports Number 8 (AutoView 1400/1500 switch), 16 (AutoView 2000 switch) Types PS/2, Sun, USB and serial AVRIQ modules or PS/2 and USB IACs C...
50 AutoView 1400/1500/2000 Installer/User Guide Appendix C: Sun Advanced Key Emulation Certain keys on a standard Type 5 (US) Sun keyboard can be emulated by key press sequences on a PS/2 keyboard. To enable Sun Advanced Key Emulation mode and use these keys, press and hold Ctrl+Shift+Alt and then p...
Appendices 51 For example: For Stop + A , press and hold Ctrl+Shift+Alt and press Scroll Lock , then F1 + A . These key combinations will work with the AVRIQ-USB module (if your Sun system comes with a USB port) as well as the Sun AVRIQ-VSN and AVRIQ-WSN modules. With the exception of F12 , these ke...
52 AutoView 1400/1500/2000 Installer/User Guide Appendix D: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible service. To ...
53 Index A adding legacy switches 10 ARI port 15 AutoView 2000 switch adding legacy switches 10 cascading 8 installing bracket 6 rack loading 6 supplied with 5 AVRIQ module 1 connecting to server 8 upgrading 44 AVRIQ Selection dialog box 31 B Broadcast dialog box 36 Broadcast Enable dialog box 37 br...
Commutateurs AutoView ® 1400/1500/2000 Guide d’installation et d’utilisation Avocent, le logo Avocent, The Power of Being There, AutoView, OutLook et OSCAR sont des marques déposées d’Avocent Corporation ou de ses filiales. Toutes les autres marques sont la propriété exclusive de leurs détenteurs re...
iii Liste des Figures..............................................................................................................v Liste des Tableaux .........................................................................................................vii Chapitre 1 : Présentation du produit .....
v Figure 1.1 : Exemple de configuration du commutateur AutoView ................................................. 3 Figure 2.1 : Installation horizontale du commutateur AutoView ..................................................... 6 Figure 2.2 : Configuration de base du commutateur AutoView ..........
vii Tableau 2.1 : Compatibilité avec les commutateurs classiques ..................................................... 10 Tableau 3.1 : Symboles d’état utilisés dans l’interface OSCAR..................................................... 16 Tableau 3.2 : Concepts de base de la navigation dans OSCAR ....
1 C H A P I T R E 1 Présentation du produit Caractéristiques et avantages Les commutateurs AutoView ® 1400/1500/2000 intègrent la technologie Avocent de commutation analogique KVM (clavier, vidéo, souris) avec une fonctionnalité de gestion de câble avancée, un accès flexible pour une utilisation sim...
Chapitre 1 : Présentation du produit 3 AutoView ou OutLook ® . Il vous est alors possible de connecter jusqu’à 256 serveurs sur un seul système. Pour de plus amples informations, reportez-vous au chapitre 2. Comptes utilisateurs locaux Grâce aux commutateurs AutoView 1400/1500/2000, les administrate...
4 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Mesures de sécurité Afin d’éviter d’éventuels problèmes de vidéo ou de clavier lors de l’utilisation des produits Avocent, prenez les précautions suivantes : • Si le bâtiment est alimenté en courant alternatif triphasé,...
5 C H A P I T R E 2 Installation Démarrage Avant d’installer le commutateur AutoView, consultez la liste ci-dessous pour vous assurer que vous disposez de tous les éléments livrés avec le matériel ainsi que des autres éléments nécessaires à l’installation. Éléments livrés avec le commutateur AutoVie...
6 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Figure 2.1 : Installation horizontale du commutateur AutoView ATTENTION : Chargement du rack : une mauvaise répartition de la charge ou une surcharge risquent d’affaiblir le rack et de faire plier les étagères, entraîna...
Chapitre 2 : Installation 7 ATTENTION : Pour éviter d’endommager votre matériel et écarter tout risque d’électrocution : - Ne retirez pas la prise de terre. Celle-ci constitue un élément de sécurité important.- Branchez le cordon d’alimentation à une prise reliée à la terre et facilement accessible ...
8 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Connexion d’un serveur à l’aide d’un module AVRIQ : 1. Repérez les modules AVRIQ du matériel AutoView. 2. Branchez les connecteurs clavier, moniteur et souris du câble aux voies correspondantes du premier serveur à reli...
Chapitre 2 : Installation 9 Dans cette configuration, l’interface OSCAR de voie locale est désactivée sur les commutateurs montés en cascade en dessous du commutateur AutoView principal. Montage en cascade de plusieurs commutateurs AutoView : 1. Connectez le commutateur AutoView en cascade à chaque ...
10 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Figure 2.3 : Configuration du commutateur AutoView 2000 avec un commutateur en cascade Ajout de commutateurs classiques Vous avez la possibilité de connecter des commutateurs classiques au commutateur AutoView en vue d...
Chapitre 2 : Installation 13 Ajout d’un commutateur KVM classique : 1. Montez le commutateur KVM primaire sur votre étagère à rack. 2. Reliez une extrémité du câble CAT 5 à une voie disponible à l’arrière du commutateur AutoView. 3. Reliez les connecteurs du clavier, du moniteur et de la souris du m...
15 C H A P I T R E 3 Opérations de base Contrôle du système par les voies analogiques Le commutateur AutoView est équipé d’un ou deux groupes de voies analogiques situés à l’arrière du commutateur qui vous permettent de relier un moniteur ainsi qu’un clavier et une souris PS/2 pour un accès analogiq...
16 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 NOTA : Vous pouvez également lancer l’interface OSCAR en appuyant deux fois de suite dans l’intervalle d’une seconde sur la touche Ctrl , sur la touche Alt , ou sur la touche Maj . Reportez-vous au chapitre Modificatio...
Chapitre 3 : Opérations de base 17 Sélection du serveur précédent : Appuyez sur Impr écran , puis sur Retour arrière . Cette combinaison de touches permet de basculer entre la connexion actuelle et la connexion précédente. Déconnexion de l’utilisateur d’un serveur : Appuyez sur Impr écran puis sur A...
18 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Navigation dans l’interface OSCAR Le tableau suivant décrit comment utiliser le clavier et la souris pour naviguer dans l’interface OSCAR. Tableau 3.2 : Concepts de base de la navigation dans OSCAR Touche(s) Action Imp...
Chapitre 3 : Opérations de base 19 Fonctions de configuration de l’interface OSCAR Vous pouvez configurer votre commutateur AutoView à partir de la boîte de dialogue Configuration de l’interface OSCAR. Cliquez sur le bouton Noms lors de la configuration initiale du commutateur afin d’identifier les ...
20 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 NOTA : Seuls les écrans Menu, Indicateur et Sécurité s’affichent pour les utilisateurs ne possédant pas de droits d’administrateurs. L’administrateur a accès à tous les écrans, à l’exception de l’écran Utilisateur, lor...
Chapitre 3 : Opérations de base 21 Figure 3.3 : Boîte de dialogue Noms NOTA : Si la liste de serveurs est modifiée, le curseur de la souris se transforme en sablier pendant que la liste est automatiquement mise à jour. Aucune opération de la souris ou du clavier n’est acceptée tant que la mise à jou...
22 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Attribution des types d’équipements Le commutateur AutoView détecte automatiquement les commutateurs KVM en cascade ; vous devez cependant préciser le nombre de voies du commutateur en cascade à l’aide de la boîte de d...
Chapitre 3 : Opérations de base 23 Figure 3.6 : Boîte de dialogue Modif. équip. 3. Choisissez le nombre de voies prises en charge par le commutateur monté en cascade et cliquez sur OK . 4. Répétez les étapes 1 à 3 pour chaque voie pour laquelle un type de dispositif doit être assigné. 5. Dans la boî...
24 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Figure 3.7 : Boîte de dialogue Menu Choix de l’ordre d’affichage par défaut des serveurs : 1. Cochez la case Nom pour afficher les serveurs par nom. -ou-Cochez la case EID pour afficher les serveurs par numéro d’EID. -...
Chapitre 3 : Opérations de base 25 Configuration du paramètre régional du clavier Le commutateur AutoView 1400/1500/2000 peut être configuré de manière à reconnaître de nombreux types de claviers. Le paramètre par défaut est le clavier américain. Si vous souhaitez modifier cette configuration, la bo...
26 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Contrôle de l’indicateur d’état L’indicateur d’état s’affiche sur le bureau et indique le nom ou le numéro d’EID du serveur sélectionné ou l’état de la voie sélectionnée. La boîte de dialogue Indicateur permet de confi...
Chapitre 3 : Opérations de base 27 3. Sélectionnez une couleur dans la zone Couleur d’affichage. 4. Dans la zone Mode d’affichage, sélectionnez Opaque pour une couleur pleine ou Transparent pour que le bureau soit visible en transparence. 5. Positionnement de l’indicateur d’état sur le bureau : a. C...
28 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Figure 3.12 : Boîte de dialogue Sécurité NOTA : La figure 3.12 représente l’écran Sécurité de l’administrateur et de l’utilisateur local lorsque la case Activer Comptes utilisateurs locaux est décochée. Seule la foncti...
Chapitre 3 : Opérations de base 29 Connexion à la console : 1. Appuyez sur n’importe quelle touche du clavier ou déplacez la souris. 2. La boîte de dialogue Mot de passe s’affiche. Saisissez le mot de passe puis cliquez sur OK . 3. La boîte de dialogue Principal s’affiche si le mot de passe saisi es...
30 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 NOTA : L’activation du mode d’économiseur d’écran déconnecte automatiquement l’utilisateur d’un serveur ; aucun serveur n’est activé. L’indicateur d’état affiche Libre . Sortie du mode d’économiseur d’écran : Appuyez s...
Chapitre 3 : Opérations de base 31 Figure 3.14 : Boîte de dialogue Sélec. Équip. 4. Sélectionnez le module AVRIQ ou IAC que vous souhaitez visualiser et cliquez sur le bouton Version . La boîte de dialogue Version Équip. s’affiche. Pour plus d’informations concernant le chargement du firmware, consu...
32 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Ajout de serveurs à la liste de balayage 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran . La boîte de dialogue Principal s’affiche. 2. Cliquez sur Config. – Balayage . La boîte de dialogue Balayage s’...
Chapitre 3 : Opérations de base 33 Figure 3.17 : Boîte de dialogue Commandes NOTA : La figure 3.17 représente l’écran Commandes de l’administrateur et de l’utilisateur local lorsque la case Activer Compte Utilisateur est décochée. Seuls les boutons Affichage Version, Réinitialiser équip. et Déconnex...
Chapitre 3 : Opérations de base 35 Lancement des tests de diagnostic : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran . La boîte de dialogue Principal s’affiche. 2. Cliquez sur Commandes - Lancer le diagnostic . Un message d’alerte s’affiche pour vous signaler que tous les utilisat...
36 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Figure 3.20 : Boîte de dialogue Diffusion NOTA : Diffusion des entrées clavier : pour que les serveurs destinataires interprètent les entrées clavier de manière identique, l’état du clavier doit être le même pour tous ...
Chapitre 3 : Opérations de base 37 Figure 3.21 : Boîte de dialogue Activer diffusion 5. Cliquez sur OK pour activer la diffusion. Cliquez sur X ou appuyez sur Echap pour retourner à la boîte de dialogue Commandes. 6. Si la diffusion est activée, saisissez les données ou effectuez les mouvements de s...
38 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Figure 3.22 : Boîte de dialogue Commutateur 3. Sélectionnez au choix le mode Préemption ou le mode Coopération comme mode de commutation. 4. Cliquez sur OK pour enregistrer les modifications. Cliquez sur la case de fer...
39 C H A P I T R E 4 Opérations avancées Utilisation des privilèges d’administrateur Les commutateurs AutoView 1400/1500/2000 permettent à quatre utilisateurs et un administrateur de se connecter à un même commutateur. Cet administrateur peut empêcher l’accès des utilisateurs à certains équipements ...
40 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Figure 4.2 : Menu Configuration (administrateur uniquement) Figure 4.3 : Menu Utilisateur (administrateur uniquement) Fonctions du menu Utilisateur (administrateur uniquement) Depuis le menu Utilisateur, l’administrate...
Chapitre 4 : Opérations avancées 41 Modification d’un utilisateur : 1. Cliquez sur le nom de l’utilisateur à modifier. 2. Cliquez sur Modifier pour modifier le nom et/ou le mot de passe de l’utilisateur sélectionné. 3. Cliquez sur Accès pour restreindre l’accès de l’utilisateur sélectionné à certain...
43 Annexe Annexe A : Mises à jour Flash Mise à jour du commutateur AutoView Avocent fournit un utilitaire spécifique vous permettant de mettre à jour le firmware du commutateur AutoView. Cet utilitaire configure automatiquement les paramètres de communication de la voie pour permettre un téléchargem...
44 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 • Vérifiez qu’une seconde exécution du programme ApplianceUpdate.exe n’est pas en cours. • Vérifiez que le câble utilisé est un câble série null modem. • Vérifiez dans les paramètres avancés de la voie COM que les mémo...
Annexe 45 Figure A.2 : Boîte de dialogue Mise à jour AVRIQ Mise à jour du firmware d’un module AVRIQ particulier : 1. Appuyez sur Impr écran . La boîte de dialogue Principal s’affiche. 2. Cliquez sur Commandes - Affichage Version . La boîte de dialogue Version s’affiche. Figure A.3 : Boîte de dialog...
48 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Annexe B : Spécifications techniques Tableau B.1 : Spécifications du produit Spécifications produit du commutateur AutoView Voies ARI Nombre 8 (commutateur AutoView 1400/1500), 16 (commutateur AutoView 2000) Types Modu...
50 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Annexe C : Émulation des touches avancées du clavier Sun Il est possible d’émuler certaines touches d’un clavier Sun (US) de type 5 standard en utilisant des combinaisons de touches sur un clavier PS/2. Pour activer le...
Annexe 51 Par exemple : Pour Arrêt + A , maintenez les touches Ctrl+Maj+Alt enfoncées et appuyez sur Arrêt défil , puis sur F1 + A . Ces combinaisons de touches fonctionnent avec le module AVRIQ-USB (si votre système Sun est équipé d’une voie USB) ainsi qu’avec les modules AVRIQ-VSN et AVRIQ-WSN Sun...
52 Guide d’installation et d’utilisation des commutateurs AutoView 1400/1500/2000 Annexe D : Assistance technique Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencon...
Installer/User Guide/Guide d’installation et d’utilisation For models: 1400, 1500 and 2000Pour les modèles 1400, 1500 et 2000 AutoView ® Switch 590-507-616 C For Technical Support: Avocent Corporation4991 Corporate DriveHuntsville, Alabama 35805-6201 USATel: +1 256 430 4000 Fax: +1 256 430 4031 Avoc...
Avocent Manuals
-
Avocent 590-222-501M
Manual
-
Avocent AutoView Wireless Switch
Manual
-
Avocent SC420
Manual
-
Avocent KVM Switches
Manual
-
Avocent ACS 6000
Manual
-
Avocent 140ES
Manual
-
Avocent CCM840
Manual
-
Avocent SM5-IF7103G3
Manual
-
Avocent 2160ES
Manual
-
Avocent 2030
Manual
-
Avocent SC100
Manual
-
Avocent DSR1020
Manual
-
Avocent DA1200D
Manual
-
Avocent PM2000
Manual
-
Avocent AMX5120
Manual
-
Avocent 5240
Manual
-
Avocent 180ES
Manual
-
Avocent SC 1x8
Manual
-
Avocent CPS1610
Manual
-
Avocent L Series
Manual