Avocent 1000R - Manuals
Avocent 1000R – Manual in PDF format online.
Manuals:
Manual Avocent 1000R
Summary
INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the...
Table of Contents Chapter 1: Product Overview Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Chapter 2: Installation Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Rac...
Contents Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1 Product Overview
Chapter 1: Product Overview 3 Chapter 1: Product Overview Features and Benefits The Avocent AutoView ® 1000R and 2000R model switches combine analog and digital technology to provide flexible, centralized control of data center servers. This solution delivers secure digital access and flexible serve...
4 AutoView 1000R/ AutoView 2000R Installer/User Guide The AVRIQ-SRL (serial) module is a DCE device that provides the primary interface between a serial device and the AutoView 1000R/2000R appliance. It provides VT100 terminal emulation, break suppression and port history in a convenient module form...
Chapter 1: Product Overview 5 Figure 1.2: Example AutoView 2000R Configuration Safety Precautions To avoid potential video and/or keyboard problems when using Avocent products: • If the building has 3-phase AC power, ensure that the computer and monitor are on the same phase. For best results, they ...
6 AutoView 1000R/ AutoView 2000R Installer/User Guide Rack mount safety considerations • Elevated Ambient Temperature: If installed in a closed rack assembly, the operation temperature of the rack environment may be greater than room ambient. Use care not to exceed the rated maximum ambient temperat...
Contents Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Rack Mounting Your AutoView 1000R/2000R . . . 10 Installing the AutoView 1000R/2000R . . . . . . . . . . 11 Adding Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2 Installation
Chapter 2: Installation 9 Chapter 2: Installation The AutoView 1000R/2000R appliance requires that the AVWorks software be installed prior to use. AVWorks software allows you to view and control a server attached to the AutoView 1000R/2000R appliance, configure and maintain the system and prevent un...
10 AutoView 1000R/ AutoView 2000R Installer/User Guide Setting up your network The AutoView 1000R/2000R appliance uses IP addresses to uniquely identify the appliances and the computers running AVWorks software. The AutoView appliance supports both BootP (a subset of DHCP) and static IP addressing. ...
Chapter 2: Installation 11 Installing the AutoView 1000R/2000R Figure 2.2 illustrates one possible configuration for your AutoView 1000R/ 2000R appliance. Follow the detailed set of procedures following Figure 2.2 to successfully install your appliance. 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 LAN Net...
12 AutoView 1000R/ AutoView 2000R Installer/User Guide CAUTION : To reduce the risk of elec tric shock or damage to your equipment -- Do not disable the power cord grounding plug. The grounding plug is an important safety feature.- Plug the power cord into a grounded (earthed) outlet that is easily ...
Chapter 2: Installation 13 2. Select option 1 from the Network Confi guration menu to set your network speed. When possible, you should set your connection manually without relying on the auto negotiate feature. Once you enter your selection, you will be returned to the Network Confi guration menu. ...
Chapter 2: Installation 15 5. Connect the other end of the CAT 5 cable to the appropriate AVRIQ module for the server you want to connect to the appliance. 6. Repeat steps 4-5 for all servers you wish to attach. Up to eight servers may be attached to the AutoView 1000R/2000R appliance through theAVR...
16 AutoView 1000R/ AutoView 2000R Installer/User Guide To add a legacy KVM switch: 1. Mount the legacy switch into your rack cabinet. Locate a length of CAT 5 cabling to connect your appliance to the AVRIQ for your legacy switch. 2. Attach one end of the CAT 5 cabling to the RJ-45 connector on the A...
Contents Controlling Your System at the Local Port . . . . . . 19 Viewing and Selecting Ports and Servers . . . . . . . . 19 Navigating OSCAR . . . . . . . . . . . . . . . . . . . . . . . . . 21 Configuring OSCAR . . . . . . . . . . . . . . . . . . . . . . . . 22 Assigning Server or Serial Device Na...
Chapter 3: Local Port Operation 19 Chapter 3: Local Port Operation Controlling Your System at the Local Port The AutoView 1000R/2000R includes a local port on the back of the appliance that allows you to connect a monitor and a PS/2 keyboard and mouse for direct local access. The appliance uses OSCA...
20 AutoView 1000R/ AutoView 2000R Installer/User Guide Viewing the status of your appliance The status of the servers in your system is indicated in the right columns of the Main dialog box. The following table describes the status symbols. OSCAR Status Symbols Symbol Description (green circle) Serv...
Chapter 3: Local Port Operation 21 To select the previous server: Press Print Screen and then Backspace . This key combination toggles you between the previous and current connections. To disengage the user from a server: Press Print Screen and then Alt+Ø . This leaves the user in a free state, with...
22 AutoView 1000R/ AutoView 2000R Installer/User Guide OSCAR Navigation Basics (continued) This Keystroke Does This Escape Closes the current dialog box without saving changes and returns to the previous one. If the Main dialog box is displayed, pressing Escape closes OSCAR and displays a status fl ...
Chapter 3: Local Port Operation 23 Setup Features to Confi gure OSCAR Feature Purpose Menu Change the server listing between numerically by port or EID number and alphabetically by name Change the Screen Delay Time before OSCAR displays after pressing Print Screen Flag Change display, timing, color ...
24 AutoView 1000R/ AutoView 2000R Installer/User Guide To access the Names dialog box: 1. If OSCAR is not open, press Print Screen . The Main dialog box will appear. 2. Click Setup - Names. The Names dialog box appears. Figure 3.3: Names Dialog Box NOTE: If new AVRIQ modules are discovered by the Au...
Chapter 3: Local Port Operation 25 5. Click OK in the Names dialog box to save your changes. -or-Click X or press Escape to exit the dialog box without saving changes. NOTE : If an AVRIQ has not been assigned a name, a combination of the EID and port is used as the default name. Assigning Device Typ...
26 AutoView 1000R/ AutoView 2000R Installer/User Guide To assign a device type: 1. In the Devices dialog box, select the desired port number. 2. Click Modify. The Device Modify dialog box appears. Figure 3.6: Device Modify Dialog Box 3. Choose the number of ports supported by your switch and click O...
Chapter 3: Local Port Operation 27 To choose the default display order of servers: 1. Select Name to display servers alphabetically by name.-or-Select EID to display servers numerically by EID number.-or-Select Port to display servers numerically by port number. 2. Click OK. To set a Screen Delay Ti...
28 AutoView 1000R/ AutoView 2000R Installer/User Guide Figure 3.8: Flag Dialog Box To determine how the status fl ag is displayed: 1. Select Name or EID to determine what information will be displayed. 2. Select Displayed to show the fl ag all the time or select Timed to display the fl ag for only f...
Chapter 3: Local Port Operation 29 Broadcasting to Servers The local user can simultaneously control multiple servers in a system, to ensure that all selected servers receive identical input. You can choose to broadcast keystrokes and/or mouse movements independently. NOTE : You can broadcast to as ...
30 AutoView 1000R/ AutoView 2000R Installer/User Guide 4. Click the Broadcast Enable checkbox to activate broadcasting. 5. From the user station, type the information and/or perform the mouse movements you want to broadcast. To turn broadcasting off: From the Commands dialog box, clear the Broadcast...
Chapter 3: Local Port Operation 31 To remove a server from the scan list: 1. In the Scan dialog box, deselect the checkbox next to the server to be removed.-or-Double-click on the server’s name or port.-or-Click the Clear button to remove all servers from the scan list. 2. Click OK. To start the sca...
32 AutoView 1000R/ AutoView 2000R Installer/User Guide Setting Console Security OSCAR enables you to set security on your local port console. You can establish a screen saver mode that engages after your console remains unused for a specified Inactivity Time. Once engaged, your console will remain l...
Chapter 3: Local Port Operation 33 3. Type the number of minutes for Inactivity Time (from 1-99) to delay activation of password protection and the screen saver feature. 4. For Mode, select Energy if your monitor is E N ERGY S TAR ® compliant; otherwise select Screen. CAUTION : Monitor damage can re...
34 AutoView 1000R/ AutoView 2000R Installer/User Guide CAUTION : Monitor damage can result from the use of Energy mode with monitors not compliant with E NERGY S TAR ® . 5. (Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you to the Security dialog box. 6. ...
Chapter 3: Local Port Operation 35 See Appendix E for information on emulating certain Sun keys using a PS/2 keyboard and special considerations for Japanese and Korean Sun USB keyboards. NOTE : Only local users can view or change keyboard country code settings. To set the keyboard country code for ...
36 AutoView 1000R/ AutoView 2000R Installer/User Guide Figure 3.15: Commands Dialog Box Viewing and Disconnecting User Connections You can view and disconnect users through the User Status dialog box. The username (U) will always be displayed; however, you can display either the server name or EID n...
Chapter 3: Local Port Operation 37 Figure 3.16: User Status Dialog Box To disconnect a user: 1. If OSCAR is not open, press Print Screen . The Main dialog box will appear. 2. Click Commands - User Status. The User Status dialog box appears. 3. Click the letter corresponding to the user to disconnect...
38 AutoView 1000R/ AutoView 2000R Installer/User Guide receive a warning indicating that all users (remote and local) will be disconnected. Click OK to confirm and begin the test. The Diagnostics dialog box appears. The top section of the dialog box displays the hardware tests. The bottom portion di...
Chapter 3: Local Port Operation 39 Figure 3.18: Diagnostics Dialog Box 5. As each test is fi nished, a pass or fail symbol appears. The test is complete when the last test’s symbol displays. 6. (Optional) If you have any Offl ine AVRIQ modules, you can click the Clear button to remove them from the ...
40 AutoView 1000R/ AutoView 2000R Installer/User Guide NOTE : This function is for Microsoft Windows - based computers only. Resetting the PS /2 on a computer running any other operating system may require that you reboot that computer. To reset the PS/2 mouse and keyboard values: 1. If OSCAR is not...
Chapter 3: Local Port Operation 41 Figure 3.21: Digital Version Dialog Box 4. Click AVRIQ (see Figure 3.20) to view individual AVRIQ version information. The AVRIQ Selection dialog box appears. Figure 3.22: AVRIQ Selection Dialog Box 5. Select an AVRIQ to view and click the Version button. The AVRIQ...
Contents Configuring the Terminal Applications Menu . . . 45 4 Terminal Operations
Chapter 4: Terminal Operations 45 Chapter 4: Terminal Operations Each individual AutoView 1000R/2000R may be configured at the appliance level through the configuration port on the back of the appliance. All terminal commands are accessed through a terminal or PC running terminal emulation software....
46 AutoView 1000R/ AutoView 2000R Installer/User Guide Enable Debug Messages This menu option allows you to configure the AutoView 1000R/2000R to display messages regarding the status of the AutoView 1000R/2000R. Once you select the level of detail to receive, the AutoView 1000R/2000R will begin to ...
Contents Appendix A: FLASH Upgrades . . . . . . . . . . . . . . . . 49 Appendix B: Using AVRIQ-SRL Modules . . . . . . . 53 Appendix C: Unshielded Twisted Pair (UTP) Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Appendix D: Technical Specifications . . . . . . . . . . 60 Appendix E:...
Appendices 49 Appendices Appendix A: FLASH Upgrades The AVRIQ is unavailable while an upgrade is in progress. When an upgrade is initiated, any current connection to the server via the AVRIQ will be terminated. If you are using AVWorks software, a server experiencing an AVRIQ firmware update may not...
50 AutoView 1000R/ AutoView 2000R Installer/User Guide d. Select TCP/IP protocol. e. Select Properties and note the IP address. 6. Assign the IP address in the AutoView 1000R/2000R, if needed: a. In the HyperTerminal window, type 1 to select Network Confi guration. b. Note the AutoView 1000R/2000R I...
Appendices 51 Figure A.1: AVRIQ Status Dialog Box 3. Select one or more types of modules to upgrade. Click Upgrade. NOTE: If your AVRIQ modules are already upgraded to the latest version of fi rmware, the Upgrade button will not appear in the AVRIQ Status dialog box. Figure A.2: AVRIQ Upgrade Dialog...
52 AutoView 1000R/ AutoView 2000R Installer/User Guide Figure A.6: AVRIQ Load Dialog Box 6. Click OK to initiate the upgrade and return to the AVRIQ Status dialog box. NOTE : During an upgrade, the AVRIQ status indicator in the Main dialog box will be yellow. The selected AVRIQ module is unavailable...
Appendices 53 Appendix B: Using AVRIQ-SRL Modules The AVRIQ-SRL module is a serial-to-VGA converter which permits VT100- capable devices to be viewed from the AutoView 1000R/2000R local port or by using the AVWorks software. The actual serial data is not accessed, but is merely displayed. All serial...
54 AutoView 1000R/ AutoView 2000R Installer/User Guide • AVR/CD Mode - This option allows you to control how the AutoView 1000R/2000R and CD lines operate. Available options are Always on and Toggle. When in Toggle mode, AutoView 1000R/2000R and CD lines are turned off for one-half second and then t...
Appendices 55 • History Key Sequence - This option allows you to defi ne the key combina-tion that enables History mode. The default key sequence is Ctrl-F9 . • Clear History Key Sequence - This option allows you to defi ne the key combination that clears the history buffer while in History mode. Th...
56 AutoView 1000R/ AutoView 2000R Installer/User Guide 5. Repeat steps 3 and 4 to confi gure additional macros. 6. When fi nished, press Enter to return to the previous screen. Using History mode History mode allows you to examine the contents of the history buffer, which contains the events that ha...
Appendices 57 AVRIQ-SRL pinouts The following table lists the pinouts for the AVRIQ-SRL module and is provided for your reference. AVRIQ-SRL Pinouts DB9-F Host Signal Signal Flow SRLSignal Pin Name/Description Name/Description 1 DCD - Data Carrier Detect Out of SRL DTR - Data Terminal Ready 2 RXD - ...
58 AutoView 1000R/ AutoView 2000R Installer/User Guide Appendix C: Unshielded Twisted Pair(UTP) Cabling The following information is intended to brief you on various aspects of con nec tion media. The performance of an AutoView1000R/2000R system depends on high quality connections. Poor quality or p...
Appendices 59 AutoView 1000R/2000R Wiring Standards (continued) Pin EIA/TIA 568A EIA/TIA 568B 7 white/brown white/brown 8 brown brown Cabling installation, maintenance and safety tips The following is a list of important safety considerations that should be reviewed prior to installing or maintainin...
60 AutoView 1000R/ AutoView 2000R Installer/User Guide Appendix D: Technical Specifications AutoView 1000R/2000R Product Specifi cations Server Ports Number 16 Types AVRIQ-PS/2, AVRIQ-USB, AVRIQ-VSN (Sun VGA),AVRIQ-WSN (Sun 13W3) and AVRIQ-SRL modules Connectors RJ-45 Sync Types Separate horizontal ...
62 AutoView 1000R/ AutoView 2000R Installer/User Guide Appendix E: Sun Advanced Key Emulation Certain keys on a standard Type 5 (US) Sun keyboard can be emulated by key press sequences on a PS/2 keyboard. To enable Advanced Sun Key Emulation mode and use these keys, press and hold Ctrl+Shift+Alt and...
64 AutoView 1000R/ AutoView 2000R Installer/User Guide Appendix F: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible servi...
590-258-002D For Technical Support: Avocent Corporation4991 Corporate DriveHuntsville, Alabama 35805-6201 USATel: +1 256 430 4000 Fax: +1 256 430 4031 Avocent International Ltd.Avocent House, Shannon Free ZoneShannon, County Clare, IrelandTel: +353 61 715 292Fax: +353 61 471 871 Avocent Asia Pacifi ...
Avocent Manuals
-
Avocent 590-222-501M
Manual
-
Avocent AutoView Wireless Switch
Manual
-
Avocent SC420
Manual
-
Avocent KVM Switches
Manual
-
Avocent ACS 6000
Manual
-
Avocent 140ES
Manual
-
Avocent CCM840
Manual
-
Avocent SM5-IF7103G3
Manual
-
Avocent 2160ES
Manual
-
Avocent 2030
Manual
-
Avocent SC100
Manual
-
Avocent DSR1020
Manual
-
Avocent DA1200D
Manual
-
Avocent PM2000
Manual
-
Avocent AMX5120
Manual
-
Avocent 5240
Manual
-
Avocent 180ES
Manual
-
Avocent SC 1x8
Manual
-
Avocent CPS1610
Manual
-
Avocent L Series
Manual