Page 2 - INSTALLATION INSTRUCTIONS; Tools and Parts; Location Requirements; You will need; WARNING; Explosion Hazard
2 INSTALLATION INSTRUCTIONS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Parts supplied: Remove parts package from dryer drum. Check that all parts were included. 4 leveling legs Parts needed: ...
Page 3 - Companion appliance spacing should also be considered.; Mobile Home - Additional Installation Requirements; To contact a qualified electrical installer.
3 Installation Clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions *Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.” Installation spacing for recessed area or...
Page 4 - Electrical Connection; If using a power supply cord:; A UL listed strain relief.; If your outlet looks like this:; GROUNDING INSTRUCTIONS; For a permanently connected dryer:
4 Electrical Connection To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ■ If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection...
Page 5 - Electrical Requirements - Canada; It is your responsibility; Electrical Shock Hazard; Improper connection of the equipment-
5 Electrical Requirements - Canada It is your responsibility ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may b...
Page 6 - Remove the screws from a; Power Supply Cord
6 Electrical Connection - U.S.A. Only 1. Disconnect power.2. Remove the hold-down screw and terminal block cover. 3. Install strain relief.Style 1: Power supply cord strain relief ■ Remove the screws from a ³⁄₄ " (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the tabs of the...
Page 7 - Style 2: Direct wire strain relief; of electrical connection:; Electrical Connection Options; *If local codes do not permit the connection of a cabinet-ground; Go to Section; Power supply cord
7 ■ Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point. Sty...
Page 8 - Connect ground wire (green or bare) of power supply cord to; external ground conductor screw. Tighten screw.; Connect the other wires to outer terminal block screws.; “Venting Requirements.”
8 1. Remove center silver-colored terminal block screw.2. Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw. 3. Connect ground ...
Page 9 - Connect ground wire (green or bare) of power supply cable to; Place the hooked ends of the other power supply cable wires; Connect the other wires to outer terminal block screws.
9 3. Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw. 4. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. 5. Tighten strain...
Page 10 - Optional 3-wire connection; ground conductor screw to an adequate ground.
10 1. Loosen or remove center silver-colored terminal block screw.2. Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw. 3. Place the hooked ends of the other p...
Page 11 - Venting Requirements; To reduce the risk of fire, this dryer MUST BE; If using an existing vent system; Use a heavy metal vent. Do not use plastic or metal foil vent.; Rigid metal vent; 5° elbows provide better airflow than 90° elbows.; Clamps; Use clamps to seal all joints.; Exhaust; Recommended hood styles are shown here.; Fire Hazard
11 Venting Requirements WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.IMPORTANT: Observe all governing codes and ordinances.The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building. If using an existing vent sys...
Page 12 - Do not use an exhaust hood with a magnetic latch.; Plan Vent System; Choose your exhaust installation type; Special provisions for mobile home installations; Determine vent path; Bend vent gradually to avoid kinking.; Housecleaning problems and health problems.
12 ■ An exhaust hood should cap the vent to keep rodents and insects from entering the home. ■ Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.). ■ Do not use an exhaust hood with a...
Page 13 - Shorten the life of the dryer.; Vent system chart; Install Vent System; wall opening around exhaust hood.; Install Leveling Legs; Excessive Weight Hazard
13 Determine vent length and elbows needed for best drying performance ■ Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those spec...
Page 14 - the bottom of the hinge.
14 Reverse Door Swing (Optional) You can change your door swing from a right-side opening to a left-side opening, if desired. Reversible Large Side-Swing Door 1. Place towel (A) on top of dryer to protect surface.2. Open dryer door. Remove bottom screws from cabinet side of hinges (C). Loosen (do no...
Page 15 - Complete Installation
15 Complete Installation 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped. 2. Check that you have all of your tools. 3. Dispose of/recycle all packaging materials. 4. Check the dryer’s final location. Be sure the vent is no...
Page 16 - INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE; SÉCURITÉ DE LA SÉCHEUSE; Outillage et pièces; Votre sécurité et celle des autres est très importante.; AVERTISSEMENT; Voici le symbole d’alerte de sécurité.
16 INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE ÉLECTRIQUE DE 29" (73,7 CM) SÉCURITÉ DE LA SÉCHEUSE INSTRUCTIONS D’INSTALLATION Outillage et pièces Rassembler les outils et pièces nécessaires avant de commencer l’installation. Lire et suivre les instructions fournies avec les outils indiqués ...
Page 17 - Exigences d’emplacement; On a besoin de; Un circuit séparé de 30 ampères.; Dégagements de séparation à respecter; *La plupart des installations requièrent un espace minimum de
17 Exigences d’emplacement On a besoin de ■ Un emplacement avec un conduit d’évacuation à proximité. Voir “Exigences concernant l'évacuation”. ■ Un circuit séparé de 30 ampères. ■ Une prise électrique avec liaison à la terre située à moins de 2 pi (61 cm) de l’un des côtés de la sécheuse. Voir “Spéc...
Page 18 - L’installation dans une maison mobile exige :; Spécifications électriques- Canada; C’est à l’utilisateur qu’incombe la responsabilité de; Communiquer avec un électricien qualifié.; Risque de choc électrique; Pour une sécheuse reliée à la terre et connectée par; INSTRUCTIONS DE LIAISON À LA TERRE; Le raccordement incorrect de
18 ■ Il faut aussi prendre en compte l’espace requis entre les appareils voisins. ■ Un espacement supplémentaire est requis si l’air est évacué à l'arrière de la sécheuse sur le côté gauche ou droit. *Espacement requis Exigences additionnelles concernant l’installation dans une maison mobile Cette s...
Page 19 - Exigences concernant l'évacuation; En cas d'utilisation du système d'évacuation existant; Conduit métallique rigide; Utiliser des brides pour sceller tous les joints.; Évacuation; Les styles de clapets recommandés sont illustrés ci-dessous.; Risque d’incendie
19 Exigences concernant l'évacuation AVERTISSEMENT : Pour réduire le risque d'incendie, cette sécheuse doit ÉVACUER L'AIR À L'EXTÉRIEUR.IMPORTANT : Observer les dispositions de tous les codes et règlements en vigueur.Le conduit d'évacuation de la sécheuse ne doit pas être connecté à une évacuation d...
Page 20 - Le clapet incliné de type boîte ci-dessous est acceptable.; Planification du système d’évacuation; Choisir un type de système d’évacuation
20 Le clapet incliné de type boîte ci-dessous est acceptable. ■ Terminer le conduit d'évacuation par un clapet de décharge pour empêcher les rongeurs et insectes d'entrer dans l'habitation. ■ Le clapet de décharge doit être situé à au moins 12" (30,5 cm) au-dessus du sol ou de tout autre objet s...
Page 21 - Déterminer l'itinéraire d'acheminement du conduit; Plier le conduit graduellement pour éviter de le déformer.; Installation du système d’évacuation; Risque du poids excessif
21 Déterminer l'itinéraire d'acheminement du conduit ■ Choisir l'itinéraire d'acheminement vers l'extérieur qui sera le plus direct et le plus rectiligne. ■ Planifier l'installation pour introduire le nombre minimal de coudes et de changements de direction. ■ Si des coudes ou des changements de dire...
Page 22 - ni déformer le conduit d’évacuation.; Inversion du sens d'ouverture de la porte; Grande porte réversible à pivotement latéral
22 Mise à niveau de la sécheuse Contrôler l’aplomb de la sécheuse. Contrôler l’aplomb tout d’abord transversalement, puis dans le sens avant/arrière . Si la sécheuse n’est pas de niveau, la déposer sur un bloc de bois. Utiliser une clé à molette pour ajuster les pieds vers le haut ou vers le bas, et...
Page 23 - Achever l’installation; le conduit d’évacuation n’est pas écrasé ou déformé.
23 6. Veiller à maintenir la plaque de carton d’espacement centrée entre les deux sections de la porte. Réassembler la section externe et la section interne de la porte de telle manière que la poignée soit orientée du côté où les charnières viennent d’être enlevées. 7. Fixer les charnières de porte ...