2 2. Remove and save the control box cover. 3. Remove and save the screws holding the control box in place. Carefully swing the control box about 90°counterclockwise. 4. Remove and discard the cap from the discharge line access fitting. 5. Place a teflon seal in the fitting of the low ambient contro...
3 10. Carefully replace the service valve panel and screws. Carefully swing the control box clockwise to it’soriginal position. Reattach it using the screws re-moved earlier. Units With A High Pressure Control 1. Remove and save the screws holding the control box cover in place. 2. Remove and save t...
4 Servicer’s Note CAUTION Avoid servicing the low ambient controlwhile the unit is operating. The rotatingfan blades could cause serious injury. If measurement of the high side pressure is required, usethe liquid line valve on the outside of the unit. Also notethat most electrical measurements for t...