Page 2 - FRONT MOUNTING; Wire; top; Thermostat Installation for DS01* Kit; Skip these steps if not installing.
2 Antenna Installation For DT01* Kit A DT01* antenna must be installed to the PTAC to allowoperation of either the DS01* remote RF thermostat or aDD01* combination PIR motion sensor and door switch. Preparation 1. Disconnect power to the unit by unplugging the powercord at the wall outlet or subbase...
Page 3 - See Binding Instructions on page 5.; Mounting Sensor/Door Magnet Installation for
3 .2. Remove thermostat from mounting plate by pulling apart. 3. Place thermostat mounting plate against the wall at de-sired location and mark placement of mounting holes. 4. If mounting in drywall, tap plastic anchors into wall. Forother surfaces, drill a 3/16” hole. 5. Screw mounting plate to the...
Page 4 - Door Magnet Installation; MAGNET HOLDER TOP
4 Door Magnet Installation Mount the door magnet holder on the front of the door where it will be as close as possible to the bottom of the motionsensor but no more then 1/8" from the bottom center of the motion sensor (DD01*) when the door is closed. Select the correct slot in the magnet holder...
Page 5 - POSITION A; POSITION C; POSITION B; RECTANGULAR INDENTATION
5 Select one of the three slots that places the magnet ½” from the sensor mounting plate on the door frame. See expamples below. The door frame and door usually will not align. Place holder on the door and select the slot that places the magnet as close as possible to the ½” depth from the back of t...
Page 6 - Binding of RF Devices; DO NOT ATTEMPT TO BIND; All must be bound at one time.
6 2. Press and then immediately release the white tactilebutton on the back of the DS01* thermostat. should now be displayed on the PTAC LED display. If does not show on the display in 1-2 seconds, then press andrelease the white button a second time. Skip this step ifthere is no thermostat. 3. Pres...
Page 7 - If; Entering Room Number (Skip if not using DP01* Front Desk Platform); HEAT
7 Configuration Settings The PTAC control will automatically self-configure to work with the wall thermostat (DS01* Kit) if installed. The PTACcontrol will automatically self-configure to activate pre-configured energy management routine when the DD01* isinstalled and bound to the PTAC. Additionally...
Page 8 - WARNING
8 Setback Temps - DD01* The DD01* and the DigiSmart control can be programmed for 3 different times to activate temperature setbacks. Thecurrent factory default temperature setbacks in v2.5 * software release are: 2º from set point in 30 minutes, 3º in one (1)hour, and 6º in three (3) hours. For eac...
Page 10 - Typical Room Layouts; C A U T I O N
10 PTAC MOTION SENSOR OUTSIDE PTAC MOTION SENSOR OUTSIDE Typical Room Layouts NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCCRules. These limits are designed to provide reasonable protectionagainst harmful interfer...