Page 2 - Manual ACM 9 - ARE i9 release
Manual ACM 9 - ARE i9 release Version: 12 Page: 2 / 52 Manual ACM9_ARE i9 release V12.docx 1. Introduction ................................................................................................................................. 5 2. ACM 9 .......................................................
Page 5 - Introduction; Typical system structure
Manual ACM 9 - ARE i9 release Version: 12 Page: 5 / 52 Manual ACM9_ARE i9 release V12.docx 1. Introduction ACM 9 Industrial Ethernet (EtherCAT®, EtherNet/IP™, Profinet®), AEG ID Communication Module, provides Industrial Ethernet connectivity for ARE i9, AEG ID RFID reader family. Both units are dedi...
Page 6 - Hardware
Manual ACM 9 - ARE i9 release Version: 12 Page: 6 / 52 Manual ACM9_ARE i9 release V12.docx 2. ACM 9 ACM 9 Industrial Ethernet communication module supports Industrial Ethernet connectivity. EtherCAT, EtherNet/IP and Profinet are implemented (only one at a time). ACM 9 has 2 Industrial Ethernet ports...
Page 7 - Connectivity
Manual ACM 9 - ARE i9 release Version: 12 Page: 7 / 52 Manual ACM9_ARE i9 release V12.docx 2.1.3 Connectivity Auxiliary Port (AUX) M12 socket 5 Pin male A-coded. Industrial Ethernet Port 1 Industrial Ethernet Port 2 Auxiliary Port Power + RS 232 4 digital Inputs 4 digital outputs Serial Port 1 ARE i...
Page 8 - Profinet
Manual ACM 9 - ARE i9 release Version: 12 Page: 8 / 52 Manual ACM9_ARE i9 release V12.docx Industrial Ethernet Port (Port 1, Port 2) M12 socket 4 Pin female D-coded (standard Industrial Ethernet) Serial Ports for ARE i9 (1-4) M12 socket 5 Pin female A-coded PIN 1 – +7V PIN 2 – GND PIN 3 – TX PIN 4 –...
Page 9 - Grounding
Manual ACM 9 - ARE i9 release Version: 12 Page: 9 / 52 Manual ACM9_ARE i9 release V12.docx Digital Inputs (input) M12 socket 8-Pin male A-coded Digital outputs (output) M12 socket 8-Pin female A-coded 2.1.4 Grounding PIN 1 – Input for serial port 1 PIN 2 – Input for serial port 2 PIN 3 – Input for s...
Page 10 - Firmware
Manual ACM 9 - ARE i9 release Version: 12 Page: 10 / 52 Manual ACM9_ARE i9 release V12.docx 2.2 Firmware ACM 9 uses 32 Byte cyclic input data and 32 Byte cyclic output data. 2.2.1 Industrial Ethernet description files Profinet: File GSDML-V2.35-AEGID-ACM9-20210310.xml contains Profinet description f...
Page 11 - ACM 9 – control via RS-232 serial interface; Read firmware version of ARE i9 hooked up to port 2 of ACM 9:
Manual ACM 9 - ARE i9 release Version: 12 Page: 11 / 52 Manual ACM9_ARE i9 release V12.docx 2.2.4 ACM 9 – control via RS-232 serial interface In addition to the Industrial Ethernet control option, ACM 9 can always be controlled directly via a RS-232 interface. The interface is located at the AUX por...
Page 12 - ACM 9 error messages
Manual ACM 9 - ARE i9 release Version: 12 Page: 12 / 52 Manual ACM9_ARE i9 release V12.docx 2.2.5 ACM 9 error messages ACM 9 itself has the following error messages. Wrong channel number (Error code #65) A wrong channel number is set to the master output data. Valid channel numbers are from ‘1’ to ‘...
Page 13 - Error messages coming through from ARE i9
Manual ACM 9 - ARE i9 release Version: 12 Page: 13 / 52 Manual ACM9_ARE i9 release V12.docx ACM 9 sets master input data to: Hex: 23 00 15 23 36 37 0D 00 … ASCII: <NAK> ‘#’ ‘6’ ‘7’ <CR> Meaning Change counter Serial interface port Error Text End character 2.2.6 Error messages coming thro...
Page 14 - ARE i9 Hardware
Manual ACM 9 - ARE i9 release Version: 12 Page: 14 / 52 Manual ACM9_ARE i9 release V12.docx 3. ARE i9 - family ARE i9 is a small industrial RFID reader that is available as a LF - SEMI Industry, LF and HF version. ARE i9 LF hdx - SEMI Industry works with LF hdx transponders. ARE i9 LF works with (al...
Page 16 - Transponder orientation relative to ARE i9
Manual ACM 9 - ARE i9 release Version: 12 Page: 16 / 52 Manual ACM9_ARE i9 release V12.docx 3.1.4 Transponder orientation relative to ARE i9 Disk parallel (recommended) Glass transponder perpendicular (recommended) Direction of travel The highest read range is achieved right above the center of ARE ...
Page 17 - Read range for SEMI application
Manual ACM 9 - ARE i9 release Version: 12 Page: 17 / 52 Manual ACM9_ARE i9 release V12.docx 3.1.5 Read range for SEMI application Glass transponder Texas Instruments RI-TRP-DR2B Glass transponder perpendicular (recommended) The highest read range is achieved right above the center of ARE i9 front si...
Page 19 - Read range for miscellaneous applications
Manual ACM 9 - ARE i9 release Version: 12 Page: 19 / 52 Manual ACM9_ARE i9 release V12.docx 3.1.6 Read range for miscellaneous applications Glass transponder and Disk transponder with different transponder chips (see table at the bottom) Disk transponder parallel (recommended) Glass transponder perp...
Page 20 - ARE i9x Hardware
Manual ACM 9 - ARE i9 release Version: 12 Page: 20 / 52 Manual ACM9_ARE i9 release V12.docx 3.2 ARE i9x Hardware ARE i9x is a small industrial RFID reader that is available as a LF - SEMI Industry and LF version. ARE i9x LF hdx - SEMI Industry works with LF hdx transponders. ARE i9x LF works with (a...
Page 21 - Protection Class
Manual ACM 9 - ARE i9 release Version: 12 Page: 21 / 52 Manual ACM9_ARE i9 release V12.docx 3.2.2 Protection Class Protection class is IP 67, if either cable is attached or a protection cap is mounted. 3.2.3 Connectivity ARE i9x is connected via its M12, 5-Pin male A-coded plug. Power supply as well...
Page 22 - Transponder orientation relative to AAN Xi9F
Manual ACM 9 - ARE i9 release Version: 12 Page: 22 / 52 Manual ACM9_ARE i9 release V12.docx If it is not possible to ensure such orientation, the Disk transponders can be oriented perpendicular to the front side of ARE i9 and glass tube transponders can be oriented parallel. This will result in some...
Page 23 - Read Range for SEMI Applications using AAN Xi9F
Manual ACM 9 - ARE i9 release Version: 12 Page: 23 / 52 Manual ACM9_ARE i9 release V12.docx 3.2.5 Read Range for SEMI Applications using AAN Xi9F Glass transponder Texas Instruments RI-TRP-DR2B Glass transponder parallel (recommended) The highest read range is achieved right above the center of AAN ...
Page 24 - Firmware ARE i9 LF hdx - SEMI Industry
Manual ACM 9 - ARE i9 release Version: 12 Page: 24 / 52 Manual ACM9_ARE i9 release V12.docx 3.3 Firmware ARE i9 LF hdx - SEMI Industry ARE i9 LF hdx - SEMI Industry reads low frequency hdx transponders, typically in glass transponder format 4mmx34mm. 3.3.1 Instruction Set Communication with ARE i9 L...
Page 25 - GT; PARAMETER
Manual ACM 9 - ARE i9 release Version: 12 Page: 25 / 52 Manual ACM9_ARE i9 release V12.docx 3.3.4 GT GT – Get Tag GT is used to retrieve the transponder UID. Input format: GT<CR> Hex: 47 54 0D ASCII: ‘G’ ‘T’ <CR> Output (example): 1234567812345678 <CR> Hex: 31 32 33 ... ... 38 0D A...
Page 26 - NID; CID
Manual ACM 9 - ARE i9 release Version: 12 Page: 26 / 52 Manual ACM9_ARE i9 release V12.docx 3.3.6 NID NID – Double reading of UID to ensure consistency in EMV polluted environment. NID is used to double read a transponder UID to ensure consistency in an EMV polluted environment. The transponder UID ...
Page 27 - CN; RD
Manual ACM 9 - ARE i9 release Version: 12 Page: 27 / 52 Manual ACM9_ARE i9 release V12.docx 3.3.8 CN CN – Filter no read from being transmitted via interface. CN is used in those cases, where no read information ‘XXXXXXXXXXXXXXXX’ is not to appear on the interface. Only valid transponder UID will be...
Page 28 - LD
Manual ACM 9 - ARE i9 release Version: 12 Page: 28 / 52 Manual ACM9_ARE i9 release V12.docx 3.3.11 LD LD – lock memory page LD is used to lock a particular memory page from a transponder in the field. Input format: LD<SP> 1<CR> Hex: 4D 44 20 31 0D ASCII: ‘L’ ‘D’ <SP> ’1’ <CR>...
Page 29 - Error messages; Error code
Manual ACM 9 - ARE i9 release Version: 12 Page: 29 / 52 Manual ACM9_ARE i9 release V12.docx The following parameters are set: TOR 50 LRD 01001 MD 2 LNRD 10001 CID 0 LERR 10011 CN 0 LED 1 LSTB 01101 LRT 30 LGT 01111 LPA 00000 3.3.14 Error messages Error messages and protocol errors are acknowledged b...
Page 30 - Firmware ARE i9 LF
Manual ACM 9 - ARE i9 release Version: 12 Page: 30 / 52 Manual ACM9_ARE i9 release V12.docx 3.4 Firmware ARE i9 LF ARE i9 LF works with (all) low frequency transponders in ASK, PSK and FSK modulation. Please see chapter 3.3.13 for details on which transponder chips are implemented. Depending on the ...
Page 34 - VSAVE
Manual ACM 9 - ARE i9 release Version: 12 Page: 34 / 52 Manual ACM9_ARE i9 release V12.docx 3.4.11 VSAVE VSAVE – Save parameter permanently in ARE i9 flash memory VSAVE is used to save parameters permanently in flash memory of ARE i9 to be available after power on. Input format: VSAVE <CR> Hex...
Page 35 - ALGO
Manual ACM 9 - ARE i9 release Version: 12 Page: 35 / 52 Manual ACM9_ARE i9 release V12.docx 3.4.13 Error messages Error messages and protocol errors are acknowledged by ARE i9 using an error code. The format is described below: <NAK> '#' <error code> <CR> Example error #02 (wrong p...
Page 38 - Firmware ARE i9 HF
Manual ACM 9 - ARE i9 release Version: 12 Page: 38 / 52 Manual ACM9_ARE i9 release V12.docx 3.5 Firmware ARE i9 HF 3.5.1 Instruction Set Communication with ARE i9 is based on a simple ASCII text based protocol. The host sends text based telegrams to ARE i9 and receives text based telegrams back cont...
Page 42 - INIT
Manual ACM 9 - ARE i9 release Version: 12 Page: 42 / 52 Manual ACM9_ARE i9 release V12.docx 3.5.11 INIT INIT – Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the parameters. Input format: INIT<CR> Hex: 49 4E 49 54 0D ASCII: ‘I’ ‘N’ ‘I’ ’T’ &...
Page 43 - LED instruction set
Manual ACM 9 - ARE i9 release Version: 12 Page: 43 / 52 Manual ACM9_ARE i9 release V12.docx 3.6 LED instruction set ARE i9 employs a multi-color LED to signal different modes. Basically below colors can be created: The user can choose any color apart from white. This color is reserved for setup help...
Page 45 - LED Transponder number successfully read (LRD)
Manual ACM 9 - ARE i9 release Version: 12 Page: 45 / 52 Manual ACM9_ARE i9 release V12.docx 3.6.3 LED Transponder number successfully read (LRD) Successful read color is green, no flash Input format: LRD<SP> 01001<CR> Hex: 4C 52 44 20 30 31 ... 31 0D ASCII: ‘L’ ‘R’ ‘D’ <SP> ‘0’ ‘1’...
Page 46 - LED Process active; Activating Process active; Deactivating Process active
Manual ACM 9 - ARE i9 release Version: 12 Page: 46 / 52 Manual ACM9_ARE i9 release V12.docx 3.6.6 LED Error (LERR) Error color is red , flashing Input format: LERR<SP> 10011<CR> Hex: 4C 45 52 52 20 31 ... 31 0D ASCII: ‘L’ ‘E’ ‘R’ ‘R’ <SP> ‘1’ ... ’1’ <CR> Output: 10011<CR&...
Page 47 - LED Process status; Successful Process; Not Successful Process
Manual ACM 9 - ARE i9 release Version: 12 Page: 47 / 52 Manual ACM9_ARE i9 release V12.docx 3.6.8 LED Process status LED Process status is used to indicate the status of a process, after it is performed. Successful Process LED color is green, not flashing Input format: LPS<SP> 01001<CR> ...
Page 49 - System implementation; Power supply
Manual ACM 9 - ARE i9 release Version: 12 Page: 49 / 52 Manual ACM9_ARE i9 release V12.docx 4. System implementation 4.1 Power supply SEMI industry uses hdx LF RFID technology. This particular method relies on field gaps, where the RFID field is switched off. In this gap the transponder answers with...
Page 50 - FCC Statement; Information to the user.
Manual ACM 9 - ARE i9 release Version: 12 Page: 50 / 52 Manual ACM9_ARE i9 release V12.docx 5. FCC Statement 5.1 ACM 9 Valid for ACM 9 – EtherCAT, ACM 9 – Profinet, ACM 9 – Ethernet/IP Federal Communications Commissions (FCC) Statement §15.21 You are cautioned that changes or modifications not expre...
Page 51 - Release, Change Protocol
Manual ACM 9 - ARE i9 release Version: 12 Page: 51 / 52 Manual ACM9_ARE i9 release V12.docx 6. Release, Change Protocol Revision: Date: Changes: Author: 01 21.09.2020 Release first edition NK 02 29.09.2020 Details added NK 03 12.10.2020 Details added NK 04 22.11.2020 Details added NK 05 09.12.2020 F...