ADTRAN TROCU DP - Manuals

ADTRAN TROCU DP – Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6

Summary

Page 2 - Repeaterless operation.; ON; SC

2 61291006L2-5B Section 61291006L2, Issue 2 2. OPTIONS Select the appropriate OPTIONS and RATE usingSW1 and faceplate switches as illustrated in Figure 3and Figure 4. C A U T I O N Select only one option rate. Rate is selected onfaceplate switch SW2 by pushing one or twoswitches to the right toward ...

Page 3 - N O T E; Table 1. Preprovisioning

3 61291006L2-5B Section 61291006L2, Issue 2 When inserted into a powered up backplane theTROCU DP and TRDDS-R will synchronize within 30to 90 seconds. When synchronized, the SYNC LOSSindicator LED will turn Off. If synchronization cannotbe achieved, check the T/R pair for an open circuit orshort cir...

Page 5 - All loops must be nonloaded.; Loop length should not exceed 50 kft.

5 61291006L2-5B Section 61291006L2, Issue 2 and manual switch settings by pressing themomentary Alternate Provisioning (AP) switchlocated on the front panel. If the channel unit isremoved from the system, the unit retains previousprovisioning information in nonvolatile RandomAccess Memory (RAM). The...