Page 2 - Front Panel Features; The Express 6530 unit has eight front panel LEDs.; Table 1; lists and describes these front panel LEDs.; Figure 2. Express 6530 Functional Overview
2 61225001L1-5D The Express 6530 can be powered from any ACpower source ranging from 90 V to 240 V atfrequencies of 50 Hz to 60 Hz, or a nominal -48 VDCpower source. The SHDSL NTU will be used to provide access tocustomer premises to E1 or Nx64K leased-lineservices, as well as primary-rate ISDN. The...
Page 4 - Figure 3. Express 6530 Back Panel
4 61225001L1-5D 2. CONNECTIONS Back Panel Features The back panel of the Express 6530 SHDSL NxNTUis illustrated in Figure 3 . The SHDSL port uses a RJ-45 connector with theinterchange circuits and pinouts listed in Table 3 . Table 3. SHDSL Pin Connections e m a N e g n a h c r e t n I n o i t p i r ...
Page 7 - Figure 4; the Green/Yellow Earth Ground Wire Must Be; STRAP MAP
61225001L1-5D 7 3. OPTIONINGHardware Optioning The strap map for the Express 6530 SHDSL NxNTUis illustrated in Figure 4 . 3-WIRE EGND P7 * 2-WIRE P6 GRN/YEL* NC AC/DC POWER V.35 (Winchester 34) * WARNING: Risk of Electric Shock. When Using a 2-Wire AC Power Connection, the Green/Yellow Earth Ground ...
Page 8 - Software Optioning; The menu tree in; Figure 5; illustrates the path to every
8 61225001L1-5D Figure 5. Express 6530 Menu Tree Software Optioning The menu tree in Figure 5 illustrates the path to every provisioning, performance monitoring, and test accesspoint in the Express 6530 menu system. 1. Unit Information Main Menu 2. Provisioning 2. L T 1. NT 1. PN127 2. V .54 2. Disa...
Page 9 - Figure 6; Full G.703 Services
61225001L1-5D 9 Cross-Connect Map The purpose of the cross-connect map is to allocatethe time slots (TS0s) from the SHDSL loop to userports (E1, V.35/X.21) and configure framing. Thecross-connect maps can be accessed via the VT100terminal screens. Select “1,” Provisioning , from the Main Menu. Choos...
Page 10 - N. Full Nx64K Service; Typical; Arrow Keys. Move Cursor; Port; SHDSL Service; E1 Port; E1 Service
10 61225001L1-5D G. Full G.703 Service If this quick key command is selected, the cross-connect map will automatically configure the timeslots for Full G.703 service, and the framing will beset for transparent. Refer to the Typical Applications subsection for more information. N. Full Nx64K Service ...
Page 11 - illustrates a cross-connect map; Figure 9; illustrates a; Figure 9. Unframed Full E1 Service
61225001L1-5D 11 Typical Applications Framed Full E1 Service is set up using the quick key“G,” and then selecting “A” to save the changes. Thescreen in Figure 8 illustrates a cross-connect map configured for Framed Full E1 Service. Unframed Full E1 Service is set up using the quickkey “G,” entering ...
Page 12 - N O T E
12 61225001L1-5D Full Nx64K 2 Mbps Service is set up using the quickkey “N,” and then selecting “A” to save the changes.The screen in Figure 10 illustrates a cross-connect map configured for Full Nx64K 2 Mbps Service. In addition, when setting up Full Nx64K 2 MbpsService, the type of line interface ...
Page 13 - Figure 12. Local Dual Sided Loopback; NTU
61225001L1-5D 13 Bit Error Rate Test The SHDSL NTU contains a built-in Bit Error RateTest (BERT). The BERT involves injecting anddetecting a Pseudorandom Binary Sequence (PRBS)toward the network on the selected payload (i.e.G.703, Nx64, or entire SHDSL payload). The PRBSused in the SHDSL NTU is PRS1...
Page 15 - ports and port services by all initiating sources. See; Table 9; for an overview. A key to the symbols; Table 9. Loopback Overview
61225001L1-5D 15 Loopbacks may be initiated via the VT100 testscreens, front panel pushbuttons, Nx64K port controlleads, or by receiving V.54 or PN127 in-band loopingsignals. Not all loopback types are available for all ports and port services by all initiating sources. See Table 9 for an overview. ...
Page 16 - All framed services operate in aligned mode.; Operation; Framed pass through; SHDSL Time Slots
16 61225001L1-5D Multiple Services The NTU supports the configuration of multipleservices. These services are routed to either theG.703/G.704 interface or the Nx64K interface. TheNx64K interface supports a single service with1 <= N <= 36. The G.703 interface (with G.704framing) supports multip...
Page 17 - The remote alarm indication (bit 3 of the TS0
61225001L1-5D 17 The NTU provides framing on the E1 port asdescribed in G.704 (sections 2.3 and 5) and G.706(section 4) and G.736. In this mode, the data arrivingat the SHDSL interface need not contain any G.704framing and the NTU generates the framing. One ormore services can be routed into time sl...
Page 18 - lists the specifications for the Express 6530; Network Interface; Table 10. Express 6530 SHDSL NxNTU Specifications
18 61225001L1-5D 4. SPECIFICATIONS Table 10 lists the specifications for the Express 6530 SHDSL NxNTU. Network Interface Line Rate:. ............................................................ SHDSL per ITU G.991.2Line Code: ............................................................ TC PAMConnect...
Page 19 - WARRANTY AND CUSTOMER SERVICE; ADTRAN International Equipment; Asia Pacific - Hong Kong
61225001L1-5D 19 5. WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product withinfive (5) years from the date of shipment if it does notmeet its published specifications or fails while inservice. Refer to ADTRAN International Equipment Warranty , Document: 60000003#I-3. Contact Cus...