Page 2 - Trademarks; reserves; 01 Explorer Boulevard
Total Access Rackmount 6-Amp Power Supply Battery Charger Installation and Maintenance Practice ii 61180043L2-5D Front Matter Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the M...
Page 3 - Revision History; this font; This font; This font; This font; NOTE; Revision
61180043L2-5D iii Revision History Conventions The following typographical conventions are used in this document: This font indicates a cross-reference link. First-time references to tables and figures are shown in this font . This font indicates screen menus, fields, and parameters. T HIS FONT indi...
Page 4 - Training
Total Access Rackmount 6-Amp Power Supply Battery Charger Installation and Maintenance Practice iv 61180043L2-5D Training ADTRAN offers training courses on our products. These courses include overviews on product features and functions while covering applications of ADTRAN’s product lines. ADTRAN pr...
Page 5 - Contents
61180043L2-5D v Contents General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 7 - GENERAL; Total Access; Figure 1; illustrates the PS/BC; Features; The Total Access PS/BC features include the following:
61180043L2-5D 1 Total Access Rackmount 6-Amp Power Supply Battery Charger GENERAL This practice is an installation and maintenance guide for the ADTRAN ® Total Access ® Rackmount 6-Amp Power Supply Battery Charger (PS/BC). Figure 1 illustrates the PS/BC (P/N 1180043L2) right and left side panels. Fi...
Page 9 - Battery Disconnect Protection Circuit; “LED Indication”; DC Over Voltage Protection; LED will turn on green and the; Alarm Relays; A standard 5
Description 61180043L2-5D 3 Battery Disconnect Protection Circuit During battery operation a protection circuit disconnects battery from the main output when battery voltage drops below 39 VDC, preventing over discharge. When AC returns, the main output provides regulated –54 VDC, batteries recharge...
Page 10 - LED Indication; Table 1; for LED descriptions. Descriptions are also labeled on the PS/BC.; Compliance; Table 1. LED Descriptions; LED; BATTERY VOLTAGE
Total Access Rackmount 6-Amp Power Supply Battery Charger Installation and Maintenance Practice 4 61180043L2-5D LED Indication A set of three PS/BC multi color LEDs provide status for AC, DC, and battery charge condi-tions. See Table 1 for LED descriptions. Descriptions are also labeled on the PS/BC...
Page 11 - INSTALLATION; Warranty”; Shipping Contents; The contents include the following items:
Installation 61180043L2-5D 5 INSTALLATION After unpacking the Total Access PS/BC, inspect it for damage. If damage has occurred, file a claim with the carrier, then contact ADTRAN Customer Service. Refer to “Appendix A, Warranty” for further information. If possible, keep the original shipping conta...
Page 12 - Figure 2; for a representative example of the PS/BC mounted to the battery.
Total Access Rackmount 6-Amp Power Supply Battery Charger Installation and Maintenance Practice 6 61180043L2-5D Mounting the PS/BC The PS/BC housing occupies a nominal area 15.35 inches (with mounting tabs) wide by 3.45 inches high and is designed so the four mounting tab screw holes align to thread...
Page 13 - Alternate Mounting; CAUTION; Ground; WARNING
Wiring Descriptions 61180043L2-5D 7 Alternate Mounting Two alternate mounting methods include mounting directly to a wall using customer supplied wood screws, or to a 16-gauge steel bracket (P/N 3265555) that mounts in the cabinet. Bracket mount location is normally at the battery position when batt...
Page 14 - Figure 3; for standard
Total Access Rackmount 6-Amp Power Supply Battery Charger Installation and Maintenance Practice 8 61180043L2-5D DC Power Output The 4-foot long, three conductor PS/BC power output wire originates at the –54V 6A OUTPUT modular connector and terminates at three #6 ring lugs for customer designated con...
Page 15 - Battery Charge/Discharge; Alarm Wiring; MAINTENANCE; Fuse; If the fuse fails, replace with a fuse of identical type and rating.
Operation 61180043L2-5D 9 Battery Charge/Discharge CAUTION To prevent battery discharge prior to system operation, do not con-nect the battery to the PS/BC until the AC power is connected orimminent. Each battery has a hardwired 6-foot battery charge/discharge wire that originates at the battery hou...
Page 16 - SPECIFICATIONS; Table 2; tions are listed in; Table 3; Table 2. Power Factor and Efficiency; Power Output vs. Efficiency; Operating Temperature:; Physical; Max power up to 50°C:
Total Access Rackmount 6-Amp Power Supply Battery Charger Installation and Maintenance Practice 10 61180043L2-5D SPECIFICATIONS Power Factor specifications for the Total Access PS/BC are listed in Table 2 . PS/BC specifica- tions are listed in Table 3 . Table 2. Power Factor and Efficiency Power Out...
Page 17 - WARRANTY AND CUSTOMER SERVICE
61180043L2-5D A-1 Appendix A Warranty WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty . Refer to the following ...
Page 18 - Carrier Networks Division
Carrier Networks Division 901 Explorer Blvd. Huntsville, AL 35806 ®