ADTRAN 1200051L2 - Manuals
ADTRAN 1200051L2 – Manual in PDF format online.
Manuals:
Manual ADTRAN 1200051L2
Summary
Trademarks: Ascend is a registered trademark of Ascend Communications, Inc.ISU is a trademark of ADTRAN, Incorporated.Macintosh is a registered trademark of Apple Computer, Inc.Teleos is a registered trademark of Teleos Communications, Inc.Windows is a registered trademark of Microsoft corporation.5...
FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of the FCC rules. On the bottom of the equipment housing is a label that shows the FCC registration number and Ringer Equivalence Number (REN) for this equipment. If requested, ...
CANADIAN EMISSIONS REQUIREMENTS This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Appara-tus," ICES-003 of the Department of Communications. Cet appareil numer...
CANADIAN EQUIPMENT LIMITATIONS Notice: The Canadian Industry and Science Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual i Table of Contents Chapter 1. Understanding ISDN and the ISU 2x64 ...................................................... 1 ISDN Overview ......................................................................................................
Table of Contents 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual iii DSR Options .......................................................................................................... 52 Flow Control (asynchronous data format) ........................................................
Table of Contents iv ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Chapter 9. Security and Remote Configuration .......................................................... 73 Security .......................................................................................................
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual v List of Figures Figure 1-1: ISU 2x64 Rear Panel .................................................................................. 2 Figure 1-2: ISU 2x64 Front Panel ........................................................................
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual vii List of Tables Table 1-A: DTE Indicators ....................................................................................... 3 Table 1-B: Recommended Operating Modes ....................................................... 7 Table...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 1 Chapter 1 Understanding ISDN and the ISU 2x64 ISDN OVERVIEW The Integrated Services Digital Network (ISDN) is a public or pri-vate switched digital network. ISDN is an international standard for digital communications, allowing a full ...
Chapter 1.Understanding ISDN and the ISU 2x64 2 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D The ISU 2x64 features two RS-530/EIA-232 DTE interfaces and two RS-366 dial interfaces (see Figure 1-1). An RS-530/EIA-232-to-V.35 adapter is available to support V.35 DTE interfaces. Syn-c...
Chapter 1. Understanding ISDN and the ISU 2x64 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 3 The ISU 2x64 allows the user to migrate ISDN into existing net-work services and data communications equipment. The ISU 2x64 interoperates with ISU 128s, Switched 56 DSUs, various ISDN ter...
Chapter 1.Understanding ISDN and the ISU 2x64 4 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Figure 1-2 ISU 2x64 Front Panel ISU 2X64 INTEROPERABILITY Telephone networks are evolving from analog technologies to digital technologies such as ISDN. This transition is time-consum-ing a...
Chapter 1. Understanding ISDN and the ISU 2x64 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 5 ENTER 123 456 789 #0 * RS CS TD RD LD TR SR ISU CANCEL ENTER 123 456 789 #0 * RS CS TD RD LD TR SR ISU CANCEL ENTER 123 456 789 #0 * RS CS TD RD LD TR SR DSU CANCEL ENTER 123 456 789 #0 * ...
Chapter 1.Understanding ISDN and the ISU 2x64 6 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D When the ISU 2x64 is used on an existing ISDN line that is not multipoint, with one SPID or no SPID numbers, additional con-siderations should be addressed. If DTE specific operation is des...
Chapter 1. Understanding ISDN and the ISU 2x64 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 7 Table 1-B Recommended Operating Modes Call Type Protocol Sync/ Async Rates Supported (bps) DIAL-64K BONDING Sync 56000 64000 Clear Chan Sync 48000 56000 64000 PPP Sync 2400 4800 9600 19200...
Chapter 1.Understanding ISDN and the ISU 2x64 8 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D 1. All asynchronous rates support flow control. 2. All dial-up modes support front panel, DTR, RS-366, AT command, and V.25 dialing methods. 3. Rates marked with f require flow control. 4. ...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 9 Chapter 2 ISDN Service ISDN ORDERING CODES ISDN is a complex service with many network options. Obtain-ing service from the local telephone company and long distance providers can be complicated. In North America, the development of IS...
Chapter 2.ISDN Service 10 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D application, then Capability R (previously Generic Data I ) may be more cost-effective. ADTRAN has registered the following ISDN ordering codes to support a variety of tariffs and applications: Capability S (pre...
Chapter 2. ISDN Service 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 11 B1 (previously Generic Data B) • 1B service • Data only • One directory number Capability C (previously Generic Data C) • 1B service • Alternating voice and data • One directory number I2 (previously Generic Da...
Chapter 2.ISDN Service 12 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D J2 (previously Generic Data J) • 2B service • 1B alternating voice/data, 1B data only • Two directory numbers M5 (previously Generic Data M-1DN) • 2B Service • 1B alternating voice/data, 1B data only • One direc...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 13 Chapter 3 Installation After unpacking the unit, immediately inspect it for possible shipping damage. If damage is discovered, file a claim immedi-ately with the shipping carrier, then contact ADTRAN Technical Support. Each ISU 2x64 i...
Chapter 3.Installation 14 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D If using ISU 2x64, part number 1200051L2, 1200051L4, 1200051L5, or 1200051L6, connect an ISDN Basic Rate S/T interface to the RJ-45 connector marked ISDN IFC. The S/T interface can be pro-vided from an S/T line ...
Chapter 3. Installation 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 15 MAINTENANCE INTERFACE The Maintenance interface is available at 9600 bps, 8 data bits, no parity, no flow control, asynchronous format through the Mainte-nance port. See Connector Pinouts on page 119 for the pi...
Chapter 3.Installation 16 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D DIAL INTERFACE CONNECTION If out-of-band RS-366 dialing is required for applications such as videoconferencing or FAX machines, the dialing interfaces of the host DTE should be connected to the dial ports marked...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 17 Chapter 4 Operation MENU NAVIGATION Moving through the various menu selections on the ISU 2x64 is a simple task. Four function keys on the left-hand side of the key-pad allow the user to enter, exit, and scroll through the various men...
Chapter 4.Operation 18 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D switch type, SPIDs, LDNs , or Leased/dial line . Also, items such as bit rate , protocol , and call type take effect only at the begin- ning of a new call. Front Panel DTE Indicators The front panel DTE indicators ...
Chapter 4. Operation 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 19 VT 100 Menu Support When connected to an asynchronous VT 100 terminal or VT 100 terminal emulator, use the built-in ISU 2x64 menu system for configuration of both DTE ports. The VT 100 screens can be acti-vated by...
Chapter 4.Operation 20 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D The menu tree allows for set up and operation of the ISU 2x64 from the front panel. The main branches of the menu tree follow: 1. STATUS 2. TEST 3. CONFIG (ConÞguration) 4. DIAL Status Buffer Selecting 1=STATUS fro...
Chapter 4. Operation 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 21 Status Screen To determine the current status of the unit, press Ctrl+V to access the Status Screen (see Figure 4-2). The Status Screen displays unit information such as the loop status, software revision, the res...
Chapter 4.Operation 22 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Configuration Screen Once the unit is selected using the terminal interface, the display shows the Configuration Menu (see Figure 4-3). This screen shows the current configuration, line, and call status for the sel...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 23 Chapter 5 Testing TEST OPTIONS Selecting 2=TEST from the top of the menu tree (Figure 5-2) or Ctrl + T from any VT 100 screen displays available local testing options; this screen is shown in Figure 5-1. Figure 5-1 VT 100 Test Menu Sc...
Chapter 5.Testing 24 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Figure 5-2 Test Menu Tree Loopback DTE This test causes the DTE port to loop back toward user equip-ment. This allows a bit error rate test (BERT) to be performed from the local end-user equipment to the ISU 2x64 to ...
Chapter 5. Testing 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 25 Loopback Remote This test causes the ISU 2x64 to issue a V.54 inband loopback command to a far-end unit. External test equipment must be used to generate/check test patterns. To use this feature, both units must be ...
Chapter 5.Testing 26 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D The ISU 2x64 must be optioned for Clear Channel operation for DDS and V.54 loopbacks to take effect. NEBE/FEBE This test reports the quality of the network connection between the T-1 and the switch by viewing the num...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 27 Chapter 6 Configuration DIAL LINE OPERATION This section explains how to configure the ISU 2x64 when using ISDN Basic Rate switched service. Figure 6-3 illustrates the entire menu tree. The following are step-by-step procedures for co...
Chapter 6. Configuration 28 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Figure 6-2 VT 100 Configuration Menu Screen Setting the Switch Protocol Find out what kind of ISDN switch the local CO is using by asking the telephone administrator or telephone company representa-tive. Confi...
Chapter 6. Configuration D ISU 2x64 Dual Port ISDN Service Unit User Manual 29 1=3002=12003=24004=48005=9600 2=DTE options 1=Netw. options 1=Asynchronous 2=Synchronous 1=24002=48003=96004=192005=38400 1=Normal2=External 6=480007=560008=640009=1120000=128000 1=Bit Rate 2=Connector Type 1=RS-530 2=V.3...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 31 Setting the Call Type Call type is configured for both DTE#1 and DTE#2 . When using the front panel, select the appropriate DTE with either arrow key and press Enter . When using a VT 100 terminal, select the ...
Chapter 6. Configuration 32 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Smart Dial Strings In some cases during a dial session it may be desired to change the call type temporarily. At the end of a dialed phone number, a #1,2,3, or 4 can be used to change the call type. A #1 chang...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 33 Setting the LDN This option allows the entry of 0, 1, or 2 LDNs. The LDN is used when receiving BONDING calls or receiving separate calls for each DTE connection. The LDN is the seven-digit local phone number ...
Chapter 6. Configuration 34 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Feature buttons are buttons that are normally available on ISDN telephone sets. The ISU 2x64 simulates pressing a feature button when the Busy Out Port option is changed. When the Busy Out Port option is chang...
Chapter 6. Configuration 36 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D 20 sec or EON: The ISU 2x64 assumes the dial string is fully entered if more than 20 seconds elapse since the last digit was keyed, or the unit receives the EON command. Wait for EON: The ISU 2x64 assumes the ...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 37 be terminated at any time by transmitting the CTRL+X (ASCII 018) after the AT attention code. The ISU 2x64 ignores this com-mand line and issues an OK response. The command line may contain a single command or...
Chapter 6. Configuration 40 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D The ISU supports the following V.25 bis commands to control automatic calling and answering: CRN . . . . . . . . . . . . . . . . . . . . Call Request (number in command) CRS . . . . . . . . . . . . . . . . . ....
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 41 Figure 6-7 Data Bits Menu Tree The setting in Figure 6-8 allows for V.25 bis messages in asyn-chronous (start/stop) data format. Figure 6-8 V.25 bis ASYNC Menu Tree Although V.25 bis allows asynchronous data f...
Chapter 6. Configuration 42 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D The first byte of each packet contains all ones (A = FF HEX), and the second byte of each packet (the C byte) is either 13 HEX or 03 HEX if not the final packet. V.25 SYNC BISYNC Dialing To set the Dial Option...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 43 Hang up line command or answered using the Answer Call command. (These commands are found under the Dial branch of the menu tree. See Front Panel Dialing Options on page 63.) Enabled When Enabled is selected, ...
Chapter 6. Configuration 44 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Figure 6-9 Answer Tone Menu Tree No Answer tone (Default) This option disables the Answer tone on all calls. Incoming tone This option enables the Answer tone on incoming calls. Outgoing tone This option enabl...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 45 Setting Connect Timout Connect Timout sets the length of time that the ISU 2x64 waits for a far-end unit to answer an outgoing call. These choices are illustrated in Figure 6-10. Figure 6-10 Connect Timout Men...
Chapter 6. Configuration 46 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D When Call Screening is set to Ansr if SN0. . .9 , an incoming call is not answered if the Call ID received from the switch does not match a stored number. Depending on the switch type, the Call ID may be prese...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 47 Select 100 ohm On to turn on the 100 ohm termination resistance across the S/T transmit and receive pairs. Select 100 ohm Off to turn off the 100 ohm termination resistance across the S/T trans-mit and receive...
Chapter 6. Configuration 48 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D modem application, where two ISU 2x64 units are directly con-nected without the use of channel banks (see Figure 6-14). The far-end unit should be configured for Slave and derives its clock- ing from the ISU 2...
Chapter 6. Configuration 50 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D DTE Options for Asynchronous and Synchronous Operation The DTE options are configured separately for both DTE#1 and DTE#2. When using the front panel, select the appropriate DTE with either arrow key and press...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 53 Figure 6-18 Flow Control Menu Tree Data Format (asynchronous) A frame consists of a start bit, 7 or 8 Data bits, 0 or 1 Parity bit, and 1 to 2 Stop bits. The settings for Data Bits, Parity Bits, and Stop Bits ...
Chapter 6. Configuration 54 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D This signal is echoed by the ISU 2x64 to the transmit clock signal on the DTE connector. See Figure 6-20 for the menu tree. Figure 6-20 Transmit Clock Menu Tree Autobaud The ISU 2x64 has a DTE rate adjustment ...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 55 Setting Protocol Options The ISU 2x64 communicates with many different types of tele-communication equipment including other ISU 2x64s, ISDN ter-minal adapters, Switched 56 DSUs, and BONDING-compatible inverse...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 57 Figure 6-22 Protocol BONDING, Mode 1 Menu Tree The timers are defined as follows: TXINIT This option specifies the length of time the originating endpoint attempts to detect BONDING negotiation pattern from th...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 59 V.110 The V.110 protocol is a CCITT compliant rate adaptation method providing DTE service between the ISU 2x64 Dual Port ISDN Ser-vice Unit and other V.110 compliant devices. The V.110 protocol supports both ...
Chapter 6. Configuration 60 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D The primary usage for SAP is general purpose asynchronous rate adaptation in a dial-up or leased environment. SAP only oper- ates on a 64 kbps data link. Figure 6-21 illustrates the menu path for selecting SAP...
Chapter 6. Configuration 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 61 When originating calls to unknown units, the ISU begins its pro-tocol selection based on its local Call Type. (Data 64k is used for FALLBACK when selected from the Quick Setup menu.) Upon connection at 64k Cal...
Chapter 6. Configuration 62 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Point-to-Point Protocol (PPP) The ISU 2x64 can be configured for PPP from the protocol options of the configuration menu by selecting 1=PPP or by setting S-reg- ister S27 to a value of 0. The menu path is show...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 63 Chapter 7 Dial Options FRONT PANEL DIALING OPTIONS Selecting 4=DIAL or pressing the # key from the front panel dis- plays the available dialing options (see Figure 7-2). Access the VT 100 Terminal Dial Options Screen (Figure 7-1) by p...
Chapter 7.Dial Options 64 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Hang up line Terminates current call. Dial number Enter and dial a number from the keypad. If an error is made, press the Down arrow to edit the number. After the number is entered, press Enter to dial the numbe...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 65 Chapter 8 Quick Setup QUICK SETUP CONFIGURATION To configure the DTE Options quickly and easily, the Quick Set- up menu is available to automatically set up the nine most com- mon DTE configurations. (See Figure 8-1.) For fine-tuning ...
Chapter 8. Quick Setup 66 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Quick Setup To aid in configuring the ISU 2x64, nine common configurations are preset for Quick Setup . These include: • Synchronous dial operation for 56, 64, 112, and 128 kbps • Asynchronous dial operation for...
Chapter 8. Quick Setup 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 67 Dial 64K sync* When the ISU 2x64 is configured for Dial 64K sync service, the fol- lowing parameters are automatically preset: Service type ............................................................ ISDN dial ...
Chapter 8. Quick Setup 70 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Leased 64K When the ISU 2x64 is configured for Leased 64K service, the fol- lowing parameters are automatically preset: Service type ................................................................ Leased LineNe...
Chapter 8. Quick Setup 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 71 Factory Setup To restore the ISU 2x64 to the factory default setup, power the unit off and perform the following steps: 1. While pressing 0 , power the unit on. 2. Continue pressing 0 until the front panel displ...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 73 Chapter 9 Security and Remote Configuration SECURITY The ISU 2x64 provides a front panel keypad locking feature to pre-vent tampering with configuration settings. The feature requires a password to access menus below the top Current-S...
Chapter 9. Security and Remote Configuration 74 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D password does not match the stored password, the LCD displays a brief message indicating that the entered password was invalid and the top menu is displayed. Set Password Set Password promp...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 77 Chapter 10 Troubleshooting When the ISU 2x64 powers up, it performs an internal self test that takes approximately 10 seconds. At the end of the test, the front panel momentarily displays Self Test Passed . If Self Test Fails If Self ...
Chapter 10. Troubleshooting 78 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D If the Euro ISDN or VN4 switch type is selected, the unit will not enter the Ready state until a setup message is sent or received (part number 1200051L5 and 1200051L6). 1. Cycle power on the ISU 2x64, leav...
Chapter 10. Troubleshooting 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 79 D. Talk to the service provider and ensure you have an ISDN Basic Rate U-Interface with 2B1Q line coding (wrong options are an S or T interface or AMI line cod-ing) when using ISU 2x64 part number 1200051L1...
Chapter 10. Troubleshooting 80 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D To isolate the problem, use the following procedure: A. Ensure the ISU 2x64 is set up for the correct switch type. B. Ensure the quality of the line is satisfactory by checking for near- and far-end block e...
Chapter 10. Troubleshooting 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 81 E. With the ISU 2x64 connected to the ISDN line and pow-ered up, talk to the service provider’s repair group and tell them you have an ISDN basic rate line that appears physically okay but is unable to regi...
Chapter 10. Troubleshooting 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 83 If the Wrong DTE Port Answers a Call A common mistake that can easily be made is entering the SPID/LDN pair swapped between the two DTE ports. For example, your telephone company has given you two SPID/LDN ...
Chapter 10. Troubleshooting 84 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D If you Cannot Connect Calls See Table 10-A for corrective actions if you cannot place calls. Table 10-A Troubleshooting Calls Condition Corrective Action The ISU 2x64 reads Ready but calls cannot be placed....
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 85 Chapter 11 Specifications Network Interface • RJ-45 for ISDN Basic Rate U-Interface, part numbers 1200051L1 and 1200051L3 • RJ-45 for ISDN Basic Rate S/T Interface, part numbers 1200051L2, 1200051L4, 1200051L5, and 1200051L6. DTE Inte...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 89 Appendix A AT Commands This Appendix lists the supported AT commands and descrip-tions of their functions. Bold text indicates default settings. Command Function A Answer. Puts the ISU 2x64 in answer mode. D Dial. Precedes the telepho...
Appendix A: AT Commands 92 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Command Function AT Command Response Message Options Q0 Response messages on Q1 Response messages off AT Command Response Message Types V0 Response messages codes V1 Response messages words AT Command Connect M...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 95 Appendix B Current Status Messages This appendix lists the status line messages and their definitions. Messages shown entirely in capital letters are generated by the ISDN network. Messages with lower case letters are generated by the...
Appendix B: Current Status Messages 96 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D DMS-100 Ready The ISU is connected to a DMS-100 switch and is ready to place/receive calls. Euro ISDN Ready The ISU 2x64 is connected to a Euro ISDN switch and is ready to place/receive calls. Getti...
Appendix B: Current Status Messages 98 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D DSTOP DSU 57.6 Async rate adaptation protocol. DSU57.6 ADTRAN DSU asynchronous protocol. FALLBACK FALLBACK rate adaptation protocol. SAP Simple Adtran Protocol. TLINK TLINK rate adaptation protocol....
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 99 Appendix C Status Buffer Messages Messages shown entirely in capital letters are generated by the ISDN network. Messages with lower case letters are generated by the ISU 2x64. Answer 1/2 The ISU answered a call on either the first or ...
Appendix C: Status Buffer Messages 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 101 BUSY The called number is busy. CallID 1 in use ISU 2x64 tried to place a call using SPID 1 when SPID 1 was al-ready in use. CallID 2 in use ISU 2x64 tried to place a call using SPID 2 when SPID 2 w...
Appendix C: Status Buffer Messages 102 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D DEST_OUT_OF_ORDER The called number is out of order. Dial1/2 The ISU 2x64 placed a call on either the first or second channel. The number called is displayed following the message. Discon1/2 The cal...
Appendix C: Status Buffer Messages 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 103 FACILITY_REJECTED A facility requested cannot be provided by the network. FACILITY_NOT_SUBSCRIBED The channel type requested has not been subscribed. FALLBACK ERROR Attempt to fallback to normal mod...
Appendix C: Status Buffer Messages 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 107 SReg Set Error Local DTE invalid S-register setting. Sync BPS < 56K The synchronous bit rate selected is too slow for the BONDING protocol. Synch Mismatch Both ends bad synchronization. TAINIT ex...
Appendix C: Status Buffer Messages 108 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D TXINIT expired Bonding timer TXINIT expired, called non-BONDING equipment or B channel not error free. UNASSIGNED_NUMBER The phone number dialed does not exist. Unknown AT & cmd User issued an u...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 109 Appendix D S-Register List S0 .........AUTO ANSWER Determines how the ISU 2x64 answers an incoming call.0 = Disable (ISU 2x64 does not answer call)1 = Enable (ISU 2x64 answers all calls) (default)2 = Dump all calls S2 .........BREAK ...
Appendix D: S-Register List 110 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D S6.........DTR DIAL DELAY Delay time in minutes between consecutive outgoing calls when DTR is set for Dial #0 if on option. S7.........CONNECT TIME Determines how long the ISU 2x64 waits for an out-going ...
Appendix D: S-Register List 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 111 S22 .......MSG BITS Miscellaneous message bits (bit 8 is most significant bit). Bit 5 = bit 6 = bit 7 = 1 allows connect message with baud rate.Bit 5 = bit 6 = bit 7 = 0 connect message without baud rate. ...
Appendix D: S-Register List 114 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D S47 .......RS 366 TIME Determines the amount of time the RS-366 port waits for either EON or inactivity to terminate a dial string before dialing a number.0 = Wait for EON only 10 = Wait for 1 second or EO...
Appendix D: S-Register List 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 115 S54 .......PROTOCOL Rate adaptation protocol type. TYPE 1 = Clear Channel (no rate adaptation) (default)2 = BONDING mode 13 = SAP (Simple Asynchronous Protocol)4 = T-link5 = V.1106 = V.1209 = DSU 57.6 kpbs...
Appendix D: S-Register List 116 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D S59 .......CHANNEL RATE Sets the available network bandwidth when the ISU 2x64 is in leased mode.3 = 64 kbps5 = 128 kbps SS60 .....SPID1 LOC Primary SPID string location. SS61 .....SPID2 LOC Secondary SPID...
Appendix D: S-Register List 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 117 S74 .......DTE STOP Selects the number of asynchronous stop bits. More than one option can be set at the same time.0 = 1 stop bit (default)1 = 1.5 stop bits2 = 2 stop bits S75 .......DTE FLOW Selects async...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 119 Appendix E Connector Pinouts Figure E-1 EIA-232 Interface Table E-A EIA-232 Interface Pin Name I/O Description 1 ............................Shield .................... I/O ........ Shield for cable2 ............................TD .....
Appendix E: Connector Pinouts 122 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Table E-D RS-366 Interface Pin Name I/O Description 1 ........................... Shield ................... I/O ........ Shield for cable2 ........................... DPR ...................... I .........
Appendix E: Connector Pinouts 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 123 Table E-F RJ-45 Dial Line Connector S/T Interface Pin Description 3 TxP 4 RxP 5 RxN 6 TxN Table E-G Maintenance Connector Pin Description 1 CD 2 RD 3 TD 4 DTR 5 SG 6 DSR 7 RTS 8 CTS 9 RING
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 125 Appendix F Ordering ISDN Without IOCs ISDN is a complex service with multiple options. Obtaining ser-vice from your local telephone company and long distance pro-viders can sometimes be complicated. This appendix guides you and your ...
Appendix F: Ordering ISDN Without IOCs 126 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D ISDN Service Ordering Information for the ADTRAN ISU 2x64 For ADTRAN ISU 2x64 applications, the following guide can be used as an aid in ordering basic ISDN service from your local telephone com...
Appendix F: Ordering ISDN Without IOCs 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 129 LOCAL INTERFACE REQUIREMENTS Physical Interface • ISDN Basic Rate Interface (BRI) line • U-interface reference point • 2B1Q line coding ISDN service must be provided from one of the following CO...
Appendix F: Ordering ISDN Without IOCs 130 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D Long Distance Service If facilities are available, subscribe to long distance service sup-porting the bearer capabilities previously listed. Request service supporting circuit-switched 64 kbps o...
Appendix F: Ordering ISDN Without IOCs 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 131 Table F-A 5ESS Features Multipoint lines require the phone company to create a SPID for each phone number on the line. With the exception of the ability to spread two calls across two phone numb...
Appendix F: Ordering ISDN Without IOCs 132 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D DMS-100 Protocol Version 1 Line Additional Parameters The Northern Telecom DMS-100 telephone switch supports a proprietary ISDN D-channel call control protocol called Pvc1 which is based on CCIT...
Appendix F: Ordering ISDN Without IOCs 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 133 After Service Is Installed When the line is installed, the following information will be pro-vided by the local phone service provider: • A seven-digit LDN for the line. If the line is multipoin...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 135 Acronyms 2B1Q 2 Binary, 1 Quarternary AMI Alternate Mark Inversion B (Channel) A 64 kbps digital information channel BONDING Bandwidth On Demand Interoperability Group bps Bits per second BRI Basic Rate Interface CCITT Consultative C...
Acronyms 136 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D PRI Primary Rate Interface SPCS Stored Program Controlled Switching System SPID Service Profile Identifier TA Terminal Adapter TE Terminal Equipment TEI Terminal Endpoint Identifier WAN Wide Area Network
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 137 Glossary asynchronous transmission Not Synchronous. A method of data transmission which allows characters to be sent at irregular intervals by preceding each character with a start bit and following it with a stop bit. The timing of ...
Glossary 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 139 DDS dataphone digital service. AT&T private line service for transmitting data over a digital system. The digital transmission system transmits electrical signals direct- ly, instead of translating the signals into tone ...
Glossary 140 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D ISDN Integrated service digital network. A network architecture that enables end-to- end digital connections. The network supports diverse services through integrat- ed access arrangements and defines a limited set of standa...
Glossary 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 141 NEXT (near-end crosstalk) Unwanted energy transferred from one circuit to an adjoining circuit. Occurs at the end of the transmission link where the signal source is located. The absorbed energy is usually propagated in the ...
Glossary 142 ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D synchronous 1. The condition occurring when two events happen in a specific time relationship with each other, both under control of a master clock. 2. A method of data trans- mission requiring the transmission of timing pul...
Glossary 61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 143 2B+D The basic rate interface (BRI) in ISDN. A single ISDN circuit divided into two 64 kbps digital channels for voice or data and one 16 kbps channel for low speed data (up to 9,600 baud) and signalling. 2B+D is carried on ...
61200051L1-1D ISU 2x64 Dual Port ISDN Service Unit User Manual 145 Index Numerics 2B1Q leased digital service 47 5ESS custom line additional parameters 130 5ESS features 131 A adapters RS-530-to-V.35 14 always tone 44 answer call 64 answer tone setting 43 async. rev. 58 AT command processor 38 AT co...
Product Support Information Presales Inquiries and Applications Support Please contact your local distributor, ADTRAN Applications En-gineering, or ADTRAN Sales: Applications Engineering (800) 615-1176 Sales (800) 827-0807 Post-Sale Support Please contact your local distributor first. If your local ...
ADTRAN Manuals
-
ADTRAN TSU 120e
Manual
-
ADTRAN 61175044L2-22B
Manual
-
ADTRAN MP-118
Manual
-
ADTRAN Small Form-Factor Pluggable Gigabit Ethernet
Manual
-
ADTRAN D4 TRI-C DP
Manual
-
ADTRAN QDFR Unit
Manual
- ADTRAN 810 Plus Manual
-
ADTRAN 1355
Manual
-
ADTRAN FE1
Manual
- ADTRAN UIG Manual
-
ADTRAN DE-4E
Manual
-
ADTRAN 1203019L3
Manual
-
ADTRAN Power Supply/Battery Charger
Manual
-
ADTRAN 1224STR PoE
Manual
-
ADTRAN HTU-C M
Manual
-
ADTRAN IP Mini-DSLAM
Manual
-
ADTRAN HRE/T200
Manual
- ADTRAN 1240 Manual
-
ADTRAN 3000 NTU-8
Manual
-
ADTRAN 1238
Manual