Page 2 - Unpacking Instructions; product. Locate the tab and peel off to remove.; Package Contents; Display unit with tabletop stand; PRODUCT REGISTRATION; Register online; AcuRite; IMPORTANT
2 Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. Unpacking Instructions Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab ...
Page 3 - Mounting Hardware
3 Features & Benefits 3-in-1 SENSOR 1. Temperature & Humidity Sensors (internal) 2. Release Lever for Battery Access3. Mounting Point4. Wind Speed Anemometer 5. Mounting Hardware Includes anchors and screws. 6. Mounting Bracket7. A-B-C Switch (not shown) ID code that must match display’s A-B...
Page 4 - Display Unit
4 Features & Benefits Display Unit 6 1 31 30 2 3 4 5 18 17 19 20 21 8 7 9 10 11 12 13 15 14 16 22 23 2625 24 292827 32 33 34
Page 6 - SETUP; Install or Replace Batteries; A B C
6 SETUP Set the A-B-C Switch The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize. Install or Replace Batteries AcuRite recommends high q...
Page 7 - Display Unit Setup
7 Display Unit Setup Set the A-B-C Switch Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize. Install or Replace Batteries 1. Remove the batt...
Page 8 - Atomic Clock; basic setup mode at any time by pressing and holding the “SET” button.; Select Measurement Units; Please note: The “WIND SPEED” history chart only displays data in “mph”.; Measurement
8 Atomic Clock AcuRite atomic clocks use a radio-controlled signal to synchronize to the correct time broadcast by the National Institute of Standards and Technology (NIST) Radio Station WWVB, located near Fort Collins, Colorado. WWVB broadcasts the current time and date with split-second accuracy.T...
Page 9 - Visit us online to view installation photos and
9 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product. Display Unit Placement Place the display unit in a dry area free of dirt and ...
Page 10 - Basic Setup is Complete; Top Mount
10 3-in-1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the ground (higher is better for wind measurement) in an open area. Secure to fence post, 2’x4’ wood, 3/4” pole, etc. (not included) LEVEL INSTALLATION Use a bubble level (not included) to ...
Page 11 - OPERATION; rior weather prediction.; Weather Forecast; temperature and wind speed readings.; Wind Speed; in AVERAGE hourly wind speed.; Barometric Pressure; lets you monitor the change in pressure over time.
11 OPERATION Using The Weather CenterLearning Mode Self-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the sel...
Page 12 - Dashes will display to confirm all MAX values have been cleared.; Troubleshooting
12 High & Low Records The “MIN/MAX” button displays minimum and maximum recordings for outdoor and indoor temperature and humidity. To view the MINIMUM temperature and humidity readings, press and release the “MIN/MAX” button until the “MIN” icon appears on the display next to the low records. T...
Page 13 - If your AcuRite product does not operate properly after trying
13 Problem Possible Solution Inaccurate forecast • Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions. • Has Learning Mode icon disappeared from the display unit? Learning Mode must complete before forecast and pressure will be accurate. • Allow unit to run...
Page 14 - Display Unit Care; Clean the Sensor; Clean the Wind Anemometer
14 FCC Information This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:1- This device may NOT cause harmful interference, and2- This device must accept any interference received, including interference that may cause undesired operation.This equipment...
Page 15 - Limited One Year Warranty; Customer Support
15 At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. We recomm...
Page 16 - It’s more than accurate, it’s; designed to provide you with information you can depend on to
©2013 Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. Patent numbers: 5,978,738; 6,076,044; 6,597,990; US 7,637,141 B2. Printed in China ...