AcuRite 869 - Manual

AcuRite 869

AcuRite 869 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

Instruction Manual

00869 Barbecue Thermometer/Timer

FEATURES:

• RF433MHz Wireless temperature transmission for convenient

BBQ or oven cooking

• 3-line LCD shows cook temperature, set temperature an timer for

BBQ or Oven cooking.

• Remote Pager with LCD showing Timer or Clock

• 23 hr 59 min Timer on main unit

• 23 hr 59 min Timer on remote pager

• High Temperature Probe that withstands temperatures up to 700 F,

with a 3 ft cable

• Compact wireless remote pager with temperature alert, timer, and

clock functions

• Temperature alert for both main unit and remote pager

• Double magnet for metal surface attachment

• Remote Pager out of range alert, 100 ft transmission range, FCC

complied

• Metal Probe wide temperature range 14 F to 392 F ( -10 C to 200 C )

• Low battery indicator

• Main unit requires 2 – “AAA” batteries

• Remote pager requires 2 – “AAA” batteries

Name/ Function of Buttons

1. Transmitter Main Unit:

Button

Press function

Hold 2 seconds

MODE

Select Timer/ Clock

Clock set

+, HR

Temp advance, HR advance

Fast advance

(press hr + min when timer stopped = clear timer)

- , MIN

Temp backward, MIN advance

Fast adjust

HR & MIN

Press at same time to clear timer

Fast advance

START/STOP

Timer start/ stop

ON/OFF

Push ON/OFF switch.

ALARM

Slide switch turn temp alarm on and off

Trade Name:

Model Number: 00869SBCA

LIMITED WARRANTY Should this product from the Chaney

Instrument Co. prove to be defective in material or workman-

ship within one year of original purchase it will be repaired or

replaced. This warranty does not cover damage in shipment or

failure caused by tampering, carelessness or abuse.

Chaney Instrument Company

965 Wells Street

Lake Geneva, Wisconsin 53147

Toll-free 24-hour support hotline: 1 (877) 221-1252

Visit our website at www.acurite.com.

2. Remote Pager:

Button

Press functions

Hold 2 Seconds

MODE

Select clock or timer

+, HR

Hour advance

Fast advance

-, MIN

MIN advance

Fast advance

HR & MIN

Press at same time to clear timer Fast advance

START/STOP

Timer start/ stop

ON/OFF

slide switch turn power on/ off

ALARM

slide switch turn temp alarm on/ off

Set-Up:

1. Battery Installation:

- Install 2 pcs AAA batteries to the main unit and the transmitter

respectively.

- Turn on the main unit and then the receiver. Slide the power

switch located on the side of the unit, to ON position

- The opposite side of the main unit and the remote pager is the

alarm switch. Slide to ON position to turn on.

- Insert probe into main unit.

- If the receiver failed to receive signal from the transmitter, the

“RANGE OUT” icon will appear and the beeper will sound. Press

any key to stop alarm. To disable the alarm, please slide the alarm

switch to OFF

2. Setting Up Clock & Thermometer for the main unit:

Press the MODE button to display clock

Hold the MODE button for 3 seconds until the time flash, press HR

and MIN to adjust

Press MODE to confirm

Press HR or MIN to select 12 or 24 hour mode

Press MODE to confirm

Press HR or MIN to select C or F

Press MODE to confirm and exit

3. Setting up clock for Remote Pager

Press MODE button to select clock display

Hold MODE key 3 second until time flash

Press HR, MIN to adjust time

Press MODE to confirm or exit

4. To Set Temperature for the main unit:

Press the MODE button to display clock

Press + or – to adjust the desired temperature. Fast advance feature

available. Hold + or – down for 2 seconds to activate fast advance.

Press MODE to confirm

5. To Set Timer for the main unit:

Press the MODE button to display timer

Press HR or MIN to enter desired count down time. Fast advance

feature available.

Press HR or MIN down for 2 seconds to activate fast advance.

Press Start/Stop to start and stop timer.

To reset timer, stop the timer then press HR and MIN at the same time.

6. To set the timer on the Remote Pager

Press the MODE button to display timer

Press HR or MIN to enter desired count down time.

Press HR or MIN down for 2 seconds to activate fast advance.

Press Start/Stop to start and stop timer.

To reset timer, stop the timer then press HR and MIN at the same time.

The Main Unit will sound an alarm when the probe is at the

desired temperature or when the count down timer is complete.

The remote pager will sound an alarm when 4 different situations

occur: when the remote pager and the main unit is out of range,

when the main unit probe is at the desired temperature, when the

main unit count down timer is complete, or when the remote

pager count down timer is complete. Note: The main unit count

down timer and remote pager count down timer is not synchro-

nized and therefore the alarm on the remote pager will sound

when the main unit count down timer is complete OR when the

remote pager count down timer is complete.

Meat-Taste temperature table is printed on the back of the main

unit.

TO SAVE BATTERIES PLEASE TURN POWER TO OFF

AFTER USE.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other AcuRite Models