Page 3 - ONTENTS; Features and Functions 1-4
C ONTENTS A BOUT T HIS G UIDE 1 I NTRODUCTION Hub 1000 SX General Description 1-1Downlinks and Uplink 1-2Full-Duplex Operation 1-2Flow Control 1-2 Asymmetric Flow Control 1-3Symmetric Flow Control 1-3Auto-Negotiation 1-3Forced Link 1-3 Features and Functions 1-4 2 I NSTALLING THE H UB Safety Precaut...
Page 5 - Online Technical Services C-1; FCC C
v B S PECIFICATIONS C T ECHNICAL S UPPORT Online Technical Services C-1 World Wide Web Site C-13Com Bulletin Board Service C-1 Access by Analog Modem C-2Access by Digital Modem C-2 3ComFacts Automated Fax Service C-23ComForum on CompuServe Online Service C-3 Support from Your Network Supplier C-3Sup...
Page 7 - IGURES
vii F IGURES 2-1 Hub 1000 SX Front and Rear Panels 2-2 2-2 Attaching a Bracket for Rack Mounting 2-4 2-3 Rack Mounting the Hub 2-4 2-4 Sample GBIC Module 2-7 3-1 Server Farm Connection 3-2 3-2 Power Workgroup Connection 3-3 3-3 Aggregated Switches Connection 3-4 3-4 Mixed Connection 3-5 3-5 Connecti...
Page 9 - ABLES; Port Configuration
ix T ABLES 1 Notice Icons 1 2 Text Conventions 2 2-1 Downlink Connections 2-5 2-2 Hub 1000 SX Indicators 2-6 2-3 GBIC Modules 2-7 2-4 Advanced RPS Configuration Options 2-10 3-1 Gigabit Ethernet Maximum Cable Lengths 3-1 3-2 Troubleshooting Tips 3-6 A-1 Situations That Require Configuring Port Setti...
Page 11 - SuperStack; Table 1; Notice Icons; Information note
A BOUT T HIS G UIDE This guide contains installation procedures and technical information about the 3Com ® SuperStack ® II Hub 1000 SX Gigabit Ethernet full-duplex repeater (part number 3C510-SX). It is assumed that the user knows basic precautions and procedures for working with electrical equipmen...
Page 12 - Convention; Screen displays; Commands; Menu commands
2 A BOUT T HIS G UIDE Table 2 Text Conventions Convention Description Screen displays This typeface represents information as it appears on the screen. Commands The word “command” means you must enter the command exactly as shown in text and press Return or Enter. For example: To remove the IP addre...
Page 13 - NTRODUCTION; The 3Com
1 I NTRODUCTION Gigabit Ethernet technology allows signal transmission at the rate of one gigabit per second (1 Gbps, or 1000 Mbps), while continuing to support IEEE 802.3 CSMA/CD local area networks. Using this technology, you can add gigabit bandwidth to critical areas of a network and fully lever...
Page 14 - Flow Control; pause frames
1-2 C HAPTER 1: I NTRODUCTION Downlinks and Uplink The hub’s eight 1000BASE-SX full-duplex downlink ports (downlinks) can connect to servers or clients that are equipped with Gigabit Ethernet network interface cards (NICs) or to 10/100 Mbps switches that are equipped with Gigabit Ethernet uplink dev...
Page 15 - Asymmetric; bidirectional; Forced Link; forced link
Flow Control 1-3 When the receiver’s input buffers can store packets again, it can either send another pause frame to tell the transmitter to resume transmission, or wait for transmission to resume. If the Hub 100 SX receives a pause frame, it does not remove the frame from the network. Instead, it ...
Page 17 - No configuration is required to install and use the hub.; Safety Precautions; WARNING; Package Contents; Rack mounting kit containing two brackets and four screws
2 I NSTALLING THE H UB This chapter describes the Hub 1000 SX package contents and provides installation procedures for the hub and for optional GBIC modules and power systems. No configuration is required to install and use the hub. Safety Precautions To avoid personal injury or damage to the Hub 1...
Page 18 - Hub Description; The hub’s front and rear panels are shown in Figure 2-1.; Hub 1000 SX Front and Rear Panels; Front Panel; or
2-2 C HAPTER 2: I NSTALLING THE H UB If you need to return the hub to 3Com, pack it in the original (or equivalent) packing material to maintain the warranty. If you ordered a GBIC module or optional power system, it is packaged separately from the hub. Hub Description The hub’s front and rear panel...
Page 19 - Rear Panel; Preparing the Site; Mounting in a Rack
Preparing the Site 2-3 Rear Panel The AC input socket accepts a 100–240 V AC power cord. Power can be supplied through optional 3Com SuperStack II Advanced Redundant Power System (Advanced RPS) and SuperStack II Uninterruptible Power System (UPS) units. These units use the DC power connector. See “U...
Page 20 - Attaching a Bracket for Rack Mounting; Repeat steps 2 and 3 for the other side of the hub.; Rack Mounting the Hub
2-4 C HAPTER 2: I NSTALLING THE H UB . Figure 2-2 Attaching a Bracket for Rack Mounting 3 Insert the two screws and tighten with a screwdriver. Do not overtighten the screws. 4 Repeat steps 2 and 3 for the other side of the hub. 5 Mount the hub in the rack and secure it with suitable screws, as show...
Page 21 - Interpreting Hub Indicators; Apply power to the hub in either of these ways:; Placing on a Desktop; Downlink Connections; SC
Interpreting Hub Indicators 2-5 7 Apply power to the hub in either of these ways: ■ Plug one end of the power cord into the AC input socket and the other end into a power source. ■ Connect the hub to a power supply, as described in “Using Optional Power Systems” later in this chapter. Placing on a D...
Page 22 - Indicator
2-6 C HAPTER 2: I NSTALLING THE H UB Table 2-2 Hub 1000 SX Indicators Indicator Color Status Meaning % BW usage meter Green Fluctuating The meter indicates the percentage of bandwidth that the hub is using. Because the hub can be connected to multiple network segments, this meter represents the aggr...
Page 23 - Installing and Connecting a GBIC Module; Sample GBIC Module
Installing and Connecting a GBIC Module 2-7 Installing and Connecting a GBIC Module The gigabit interface connector (GBIC) port on the rear panel of the Hub 1000 SX chassis accepts an optional 3Com GBIC module that permits connection to a Gigabit Ethernet device. GBIC modules must be ordered separat...
Page 24 - Advanced RPS
2-8 C HAPTER 2: I NSTALLING THE H UB To install and connect a GBIC module, follow these steps: 1 Disconnect all power to the Hub 1000 SX. Disconnect the AC power cord. If you are using an Advanced RPS unit, disconnect the RPS cable from the DC power connector. 2 Remove the GBIC module from its shipp...
Page 25 - Using Optional Power Systems; Power Modules; Table 2-4 summarizes the Advanced RPS configuration options.
Using Optional Power Systems 2-9 Power Modules At least one SuperStack II Advanced Redundant Power System Power Module Type 2 is required for each SuperStack II hub that you want to protect. The Hub 1000 SX requires the 100-watt, 3.3-volt version of the module (part number 3C16074). One Advanced RPS...
Page 26 - Uninterruptible; A hub connects to a UPS unit through the hub’s AC power cord.; Advanced RPS Configuration Options; Standard usage
2-10 C HAPTER 2: I NSTALLING THE H UB When switching from Advanced RPS (DC) to AC power or from AC power to Advanced RPS power, the Hub 1000 SX unit resets itself. For example, if both the RPS and AC cables are plugged in, and then either is removed, the unit resets itself when it changes to the oth...
Page 29 - Connecting the downlink of one Hub 1000 SX to the uplink; Gigabit Ethernet Maximum Cable Lengths
3 M AKING C ONNECTIONS This chapter contains guidelines for making typical Hub 1000 SX network connections and for troubleshooting problems with the hub. When making hub connections, follow the rules for maximum cable lengths, which are summarized in Table 3-1. If you connect 10/100 Mbps devices to ...
Page 30 - You can use the Hub 1000 SX downlinks to aggregate servers into; Server Farm Connection
3-2 C HAPTER 3: M AKING C ONNECTIONS Aggregating Servers You can use the Hub 1000 SX downlinks to aggregate servers into server farms . First, install 3Com 3C985-SX Gigabit EtherLink ® Server NICs in each server. Then, connect up to eight servers through the downlinks. The hub’s optional gigabit int...
Page 31 - Aggregating Switches; Power Workgroup Connection; The Hub 1000 SX does not support bandwidth aggregation (trunking).
Aggregating Switches 3-3 Figure 3-2 Power Workgroup Connection Aggregating Switches You can use the Hub 1000 SX downlinks to aggregate 10/100 Mbps switches such as the 3Com SuperStack II Switch 1000, Switch 3000, or Switch 3900. The Switch 1000 and Switch 3000 units must be equipped with Gigabit Eth...
Page 32 - Aggregated Switches Connection; Mixing Connections
3-4 C HAPTER 3: M AKING C ONNECTIONS Figure 3-3 Aggregated Switches Connection Mixing Connections You can vary connections according to your requirements. For example, you can connect a number of servers and 10/100 Mbps switches through the downlinks, and connect to the network backbone through the ...
Page 33 - Connecting Through the Uplink; Mixed Connection
Connecting Through the Uplink 3-5 Figure 3-4 Mixed Connection Connecting Through the Uplink The best use of the hub uplink is as a backbone connection to a 3Com SuperStack II Switch 9300 Gigabit Ethernet switch, as shown earlier in Figure 3-1 through Figure 3-2. Although two Hub 1000 SX units can be...
Page 34 - Uplink Connection to a 10/100 Mbps Switch; Troubleshooting; Table 3-2 summarizes some common problems and their solutions.; Troubleshooting Tips; There is no link connection.
3-6 C HAPTER 3: M AKING C ONNECTIONS The Hub 1000 SX itself can be used as the network backbone by connecting the uplink to a server equipped with a 3C985-SX Gigabit EtherLink Server NIC or to a 10/100 Mbps switch equipped with a 3C16925 uplink device (see Figure 3-6). For these backbone connections...
Page 35 - Console Port
A U SING THE C ONSOLE P ORT The Hub 1000 SX is ready to use and requires no configuration. However, on rare occasions you may need to confirm a POST failure, change a port’s configuration, or update the firmware image to install a bug fix or a standards update. The console port provides access to a ...
Page 36 - Requirements; With Power; * Hub 1000 SX *
A-2 A PPENDIX A: U SING THE C ONSOLE P ORT Requirements To use the console port and CLI, you need: ■ A PC with a serial port ■ A null modem cable ■ A terminal-emulation program If you need to perform a firmware update, the terminal-emulation program must support one of these file transfer protocols:...
Page 37 - Connecting the Console Port; data bits; POST Messages
Connecting the Console Port A-3 With Power Disconnected To connect the console port when the hub is disconnected from power: 1 Connect a null modem cable between the PC serial port and the console port on the Hub 1000 SX rear panel. 2 Turn on the PC. 3 Start the terminal-emulation program. 4 Configu...
Page 38 - Hardware Version 0; Logging On; The default password that is set at the factory is; admin; Configuration
A-4 A PPENDIX A: U SING THE C ONSOLE P ORT Hardware Version 0 Bootcode Version 1.00, 02/05/98 Firmware Version 1.00, 02/05/98 **************************************************** * * * SuperStack II (tm) * * Hub 1000 SX * * Copyright (c)1997 3Com Corporation * * * ***********************************...
Page 39 - Changing the Password; The following sections show examples of how to use the Hub 1000 SX; Situations That Require Configuring Port Settings; You do not want a port to be connected.
Changing the Password A-5 Changing the Password You can change the password if you need to. The new password must be eight characters or fewer and cannot contain spaces or tabs. To change the password, enter: 4 You are prompted to enter the old password and then the new password, as shown in this ex...
Page 40 - To display the
A-6 A PPENDIX A: U SING THE C ONSOLE P ORT To display the Port Configuration menu: 1 At the Configuration menu prompt, enter: 1 2 At the next prompt, enter the numbers of the ports that you want to configure. You can specify a single port number, multiple port numbers separated by commas or spaces (...
Page 41 - Configuring Port Settings; Disabling Ports; Disable the port for linking.
Configuring Port Settings A-7 Disabling Ports The following example shows how to disable ports 3, 5, 6, and 7 and apply the changes. *************************************************** ** Hub 1000 Configuration Menu ** *************************************************** [1] Configure port settings [...
Page 42 - Changes applied; Disabling; Disabling the auto-negotiation capability enables
A-8 A PPENDIX A: U SING THE C ONSOLE P ORT (5) Show port settings (6) Use factory default settings (7) Save new port settings (8) Exit without change to settings (9) Apply changes and exit Selected ports: 3, 5, 6, 7 Enter choice -> 2 **** Port Configuration Menu **** (1) Enable port (2) Disable p...
Page 44 - Configuring
A-10 A PPENDIX A: U SING THE C ONSOLE P ORT Because option 7 has been selected, the settings will persist after a hub reset. **** Port Configuration Menu **** (1) Enable port (2) Disable port (3) Enable Auto-Negotiation (4) Disable Auto-Negotiation (Force link) (5) Show port settings (6) Use factory...
Page 46 - indicates yes and; Hub Status Information
A-12 A PPENDIX A: U SING THE C ONSOLE P ORT Displaying Hub Status Hub status includes a matrix of information about the hub ports. In this matrix, Y indicates yes and n indicates no. (See Table A-3.) Table A-3 Hub Status Information Category State Description Port is enabled Y The port is enabled fo...
Page 47 - Displaying Hub Status
Displaying Hub Status A-13 Hub status also includes POST and fan status, bandwidth utilization, hardware and firmware version, and MAC address. The sample hub status display that follows is the result of the changes made in the previous section. To view the hub status, enter: 2 When you have finishe...
Page 48 - To restore port settings to factory defaults:; Ports set to factory defaults
A-14 A PPENDIX A: U SING THE C ONSOLE P ORT Restoring the Factory Default Settings To restore port settings to factory defaults: 1 At the Configuration menu prompt, enter: 1 2 Enter the numbers of the ports to be restored to factory defaults. 3 At the Port Configuration menu prompt, enter: 6 4 Apply...
Page 49 - Checking the
Updating the Firmware Image A-15 **** Port Configuration Menu **** (1) Enable port (2) Disable port (3) Enable Auto-Negotiation (4) Disable Auto-Negotiation (Force link) (5) Show port settings (6) Use factory default settings (7) Save new port settings (8) Exit without change to settings (9) Apply c...
Page 50 - Transferring the; To transfer the firmware image file:
A-16 A PPENDIX A: U SING THE C ONSOLE P ORT Transferring the Firmware Image File Make sure that the terminal-emulation program supports one of the following file transfer protocols: Xmodem, Xmodem-1K, or Xmodem-CRC. To transfer the firmware image file: 1 Obtain the file that contains the firmware im...
Page 51 - When prompted, enter the filename of the firmware image file.; File transfer successful.; Logging Off; To log off the CLI, at the Hub 1000 SX
Logging Off A-17 7 When prompted, enter the filename of the firmware image file. The terminal-emulation program begins to transfer the firmware image file. If you want to stop the file transfer, use the appropriate command in the terminal-emulation program. After the transfer is finished, the CLI di...
Page 52 - File Transfer Error Messages; Fatal Error Messages
A-18 A PPENDIX A: U SING THE C ONSOLE P ORT Table A-5 lists fatal error messages. These messages indicate that the memory unit has failed. If you see a fatal error message, return the unit to the supplier. Table A-4 File Transfer Error Messages Message Meaning Action Xmodem error: Timed out sending ...
Page 53 - PECIFICATIONS; Physical Dimensions; Electrostatic discharge:
B S PECIFICATIONS This appendix lists the specifications for the SuperStack II Hub 1000 SX. Physical Dimensions Environmental Operating Ranges Power Requirements Height: 4.37 cm (1.72 in.) Width: 43.94 cm (17.3 in.) Depth: 30.48 cm (12 in.) Weight: 5.5 kg (12 lb) Operating temperature: 0˚ to 50 ˚C (...
Page 55 - World Wide Web site; automated fax service; World Wide Web Site; Net Age; Com Bulletin
C T ECHNICAL S UPPORT 3Com provides easy access to technical support information through a variety of services. This appendix describes these services. Information contained in this appendix is correct at time of publication. For the very latest, we recommend that you access 3Com Corporation’s World...
Page 56 - Access by Analog Modem; Country
C-2 A PPENDIX C: T ECHNICAL S UPPORT Access by Analog Modem To reach the service by modem, set your modem to 8 data bits, no parity, and 1 stop bit. Call the telephone number nearest you: Access by Digital Modem ISDN users can dial in to 3ComBBS using a digital modem for fast access up to 56 Kbps. T...
Page 57 - Support from Your Network Supplier; ComForum on; Log on to your CompuServe account.; go threecom; A list of system hardware and software, including revision levels
Support from Your Network Supplier C-3 Local access numbers are available within the following countries: 3ComForum on CompuServe Online Service 3ComForum contains patches, software, drivers, and technical articles about all 3Com products, as well as a messaging section for peer support. To use 3Com...
Page 58 - Support from 3Com; Australia
C-4 A PPENDIX C: T ECHNICAL S UPPORT Support from 3Com If you are unable to receive support from your network supplier, technical support contracts are available from 3Com. Contact your local 3Com sales office to find your authorized service provider using one of these numbers: Regional Sales Office...
Page 59 - Returning Products for Repair; Latin America
Returning Products for Repair C-5 Returning Products for Repair Before you send a product directly to 3Com for repair, you must first obtain a Return Materials Authorization (RMA) number. Products sent to 3Com without RMA numbers will be returned to the sender unopened, at the sender’s expense. To o...
Page 61 - LOSSARY; Com SuperStack II Advanced Redundant Power System.; asymmetric; See also; backbone
G LOSSARY 10BASE-T The IEEE 802.3 physical layer specification for a 10 Mbps Ethernet network over two pairs of Category 3, 4, or 5 UTP wire. 100BASE-T The group of IEEE 802.3 physical layer specifications for a 100 Mbps Ethernet network over various wiring specifications. 1000BASE-X The group of IE...
Page 62 - symmetric flow control.
2 G LOSSARY bidirectional flow control See symmetric flow control. CSMA/CD Carrier Sense Multiple Access/Collision Detection. Channel access method used by Ethernet and IEEE 802.3 in which devices transmit only after finding the data channel clear for some period. When two devices transmit simultane...
Page 63 - The ability of a device to receive pause frames.
G LOSSARY 3 IEEE Institute of Electrical and Electronics Engineers. Committees that develop and propose computer standards, such as the 802 protocols, which define the physical and data link protocols of communication networks. Members represent an international cross section of users, vendors, and ...
Page 64 - bidirectional flow
4 G LOSSARY SC A fiber-optic cable connector. When it is pushed into place, the connector is seated automatically. STP Shielded twisted-pair. Shielded four-conductor electrical cable that offers high-speed transmission for long distances. SuperStack 3Com system of stackable hubs, servers, switches, ...
Page 65 - NDEX; Symbols
I NDEX Symbols % BW usage meter 2-6 Numbers 1000BASE-CX 1-2 1000BASE-LX 1-2 1000BASE-SX 1-2 1000BASE-X cables and connectors 3-1 3C16925 Gigabit Ethernet SX uplink module 3-3 3C985-SX Gigabit EtherLink Server NIC 3-2 3Com Bulletin Board Service (3ComBBS) C-1 3Com sales offices C-4 3Com URL C-1 3ComF...
Page 69 - Com Corporation; IMITED
3Com Corporation L IMITED W ARRANTY +5 Limited Warranty The duration of the warranty for the SuperStack II Hub 1000 SX is five (5) years, with the exception of the product’s fans and power supplies, which are warranted for the first year only. Advance hardware replacement will be provided for one (1...
Page 70 - LASS; A V; ERIFICATION
L IMITATION OF L IABILITY TO THE FULL EXTENT ALLOWED BY LAW, 3COM ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, ...